HomeMy WebLinkAboutBuilding PlansTRUCTION BY PORT ST LUCIE PROPERTIES 2401 SW MONTEREY LANE, PORT ST LUCIE, FLORIDA, 34953 MODEL: (772) 336-0050 CONSTRUCTION OFFICE: (772) 249-0089 WWW.PORTSTLUCIECUSTOMPROPERTIES. COM DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE PROJECT NAME: PROPOSED GARCIA RES. I OCCUPANCYTYPE: R STREET ADDRESS : TBD GOPHER RIDGE., FORT PIERCE FL 34982 CONSTRUCTION TYPE: V PERMIT NUMBER: CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL POSITION OF THE BUILDING CODES CURRENTLYADOPTED AND ENFORCED BY THE ST LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. FLORIDA BUILDING CODE: 2017 EDITION WITH: X SUPPLEMENTS AND ASCE 7 -10 2. STRUCTURE DESIGNED AS :ENCLOSED: X PARTIALLY ENCLOSED: OPEN BUILDING: 3. RISK CATEGORY : 111 X III -IV- EXPOSURE CATEGORY: B _ C X D 4. DESIGN WIND VELOCITY: 160 MPH 124 ASD NIA LRFD END ZONE WIDTH : 5' 5. MEAN ROOF HEIGHT: +A 12L9" ROOF PITCH : 6112 PARAPET: WA FT 6. COMPONENTS & CLADDING WIND PRESSURES USED: (PSF, BASED ON 10 SQ. FT. @ 10' MRH) ZONE 1: + 19.3 ZONE 2: + 19.3 ZONE 3: + 19.3 ZONE 4: + 33.6 ZONE 5: + 33.6 GARAGE: + 28.2 -30.7 -51.9 -76.2 -36.4 -44.9 -31.5 7. DESIGN LOADS: FLOOR: 40 PSF ROOF/DEAD: 5 PSF ROOF/LIVE: 20 PSF BALCONY' NSA PSF DOCK: NIA PSF DECK : NZA PSF STAIRS : NIA PSF FENCE: NIA PSF RAILING- NIA PLF / CONCENTRATED 8. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE: YES X NO (NOT APPLICABLE EXPLAIN WHY NOT) 9. IS A CONTINUOUS LOAD PATH PROVIDED: X YES (NOT APPLICABLE EXPLAIN WHY NOT) 10. DESIGN SOIL BEARING PRESSURE: 2000 PSF SOIL TEST REPORTS SUBMITTED? YES AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CEERTIFICATION IS TRU AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME: BOWDOIN G. HUTCHINSON, P.E. CERT.# & CO. CERT AUTH. 70878 DESIGN FIRM: BENCHMARK ENGINEERING DATE: ADDRESS: 806 DELANAREAVE.FORT PIERCE FLORIDA PROPOSED GARCIA RESIDENCE TBD GOPHER RIDGE RD. FT. PIERCE, FL. 34982 PLANS AND ENGINEERING BY BENCHMARK ENGINEERING FDOH in St. Lucie County EnyiwpxPental Health __SAe -PIA6 Approved for Construction Supersedes All Previous Site Plans for OSTD # �5 D& Well # 511" 3�'�� Date: L\ b Reviewer: ST LUCIE COUNTY, FLORIDA PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING& REGULATIONS DIVISION PRODUCT REVIEWAFFIDAVIT BUILDING PERMIT NUMBER: OWNERSNAME: SALVADOR GARCIA APPLICANT: PRODUCT OPENING DESIGN PRESSURES PRODUCT RATED DESIGN PRESSURES MANUFACTURER MODEL NUMBER PRODUCT APPROVAL NUMBER GLASS TYPE METHOD OF ATTACHMENT IMNDOWS SEE ELEVATIONS + 1- 5&0 MI WINDOWS &DOORS 185 SH FL # 17499.1 IMPACT 3/1B" X 1-11W MIN. EMBED TAPCONS AT 2" / 16" O.C. WINDOWS SEE ELEVATIONS +50 / - 63.0 MI WINDOWS & DOORS 185 PW FL # 15349.5 IMPACT 316' X 1-1/4" MIN. EMBED TAPCONS AT 3"O.C. MULLIONS NIA N/A N/A NIA I N/p NIA BLOCK GLASS N/A N/A N/A N/A N/A N/A N/A SKYLIGHTS N/A N/A NIA NIA N/A N/A N/A SLIDING GLASS DOORS SEE ELEVATIONS +/- 55.0 MI WINDOWS & DOORS 1201130/140 SGD FL # 22401.3 IMPACT (2 ROWS) 1/4' X 1-1/4" MIN. EMBED TAPCONS AT 6" / IS- D.C. SWING TYPE DOORS SEE ELEVATIONS +SOLO THERMA-TRU SMOOTH STAR FL # 20468.1 N/A 1/4" X 1.1/4" MIN. EMBED TAPCONS AT V114" O.C. FRENCH DOORS N/A N/A GARAGE DOORS SEE ELEVATIONS +55/-64 DAB 73W6 NOA#18-0301.07 NIA 5/16'X i-SW MIN. EMBED LAG SCREWS ONE PER BRACKET) HURRICANE PROTECTION N/A N/A N/A N/A N/A N/A N/A ROOF VENTILATION ROOFING MATERIALS -76.2 150 -180 194 TAMCO OWENS CORNING COOL RIDGE ARCH. ASPHALT SHINGLE FL#4103.1 FL#10674.1 N/A NIA FASTEN USINGMIN.0.125'SHANK DIAMIN. DA10' DIA HEAD MIN. 2.52" LONG CORSTANT ROOFING NAILS SPACED 2q O.CR ON EIITHEON ERR SLIDE OF THE RIDGE SLOT ONTO SHEATHING FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS STEEL, ALUMINUM OR COPPER ROOFING NAILS, MINIMUM 12 GAUGE (0. 10 INCH (3MM) SHANK WITH AMINIMUM SM INCH (10MM) DIAMETER HEAD, ASTM F 1667, OF LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND AMINIMUM 3141NCH (19MM) INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN 3/4 SHEATHNG)FAsi NERS SHHALLi COMPLY WITH ASTSHALL PENETRATE 1 6T7 ROUGH THE I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, AND HAVE APPROVED THEIR USE IN THIS STRUCTURE TO PROVIDE ADEQUATE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. NAME: BOWDOIN G HUTCHINSON, P.E. SIGNATURE: ON PLAN DESIGN PROFESSIONAL: BENCHMARK ENGINEERING CERTIFICATION NO.70878 GENERAL NOTES 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFYALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2014 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. ENERGY CONSERVATION NOTES 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017 ENERGY CONSERVATION RESIDENTIAL. 2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPEDAND INSULATED TOALEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. 3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMITAIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. 4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3. 5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH FBC 2017 ENERGY CONSERVATION R401.3. ELECTRICAL NOTES 111"11w G Ht Q1 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2014 EDITION. �I 2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE •'• HIGH-EFFACY LAMPS ORAMINIMUM OF 75% (F THE PERMANENTLY INSTALLED LIGHTING FIXTUR SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED A F TO BE HIGH-EFFACY LAMPS) 3) RECESSED LIGHTING SHALL BE SEALED TO LIMITAIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4) SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP -ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FORALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBCAND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FORALL 125-VOLT, SINGLE-PHASE 15 AND 20AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OFANY SINK. 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS. 9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. .0)PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. ADDITIONAL NOTES 1) INTERIOR TO BE W DRYWALL FINISH. 2)ALL INTERIOR GYPSUM BOARD TO BE MIN, Y.' THICK WITH (13 GAGE, 1 3/8" LONG, 19/64" HEAD; 0.098" DIAMETER, 1 Y.." LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 5164" HEAD; OR GYPSUM BOARD NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1326, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERSRECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWERAREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 4) WALLAND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5) WALLAND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALLASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME •� SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX . NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2000 PSF (MIN.). 3)ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAV5 A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 I SEE PLAN FOR SIZES & STEEL REQUIREMENTS. �' I 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3"BEAMS: 1 WSUSPENDED SLABS: 1 W' 6) LAP ALL REINFORCING STEEL MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEE MINIMUM IN BEAMS AND COLUMNS. T)ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES 10) UNLESS OTHERWISE NOTED, FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5' LONG AND 0.131 DIA. 11) LINTELS SHALL HAVE A MINIMUM 4" BEARING. 12) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 13) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8' 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 1913T COX PLYWOOD WITH 10D NAILS TO STUDS @ 6" O.C. PERIMETERAND FIELD. 14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. `-O to Z � 5 Z z LU 2 W Z °o o� u 00 V �O O X O 0) 0 , Z )- � � Od 4 7 W LU a Z J W o PLAN SHEET INDEX COVER SHEET 1 SHEET 2 FLOOR PLAN 1.,)4 SHEET 3 ELEVATIONS 1( SHEET 4 ELECTRICAL SHEET 5 UNDATION SHEET 6 BLOCK PLAN SHEET 7 HVAC PLAN SHEET 8 TRUSS PLAN SHEET 9 DETAILS SHEET 10 DETAILS SHEET 11 SHEET 12 PLAN SHEET INDEX g C 19 52'-0" 12'4' 16'-10" 22'-10" 4'-7" X-2" 4'-7" 10'-10" V-0" SH-25I EGRESS SH-25 SH-25 / EGRESS ■ ■ ■ ■ No_- - - - - - - - - - - - - ■ qe 8'-1"FLAT CEILING O�ryh 7._7,. C4 3 "-- - --— ---- - - - - -- --, ■ 11._03/„ I 6'-2" NOOK I Q i+ 8-1"FLAT CEILING ■ 8H I BEDROOM #2 ■ ■ - ■ ■ ■ START OFVAULT - I I N 8=1"FLATCEILING 6068/TEMP/SGD. 3'-8" V-0° MASTER BEDROOM ■ S V-3%" - ,.: r 8'-1"FLAT CEILING I I _ 9'-4"COFFER CEILING I ■ � I I N ROOM 0O)� p I , 1-5/3 w GREAT 14'-0'/2" 6'-0" VAULTED CEILING p ■ 4 �St` U 0'O . 14'-2'/"" KITCHEN 0 3„ i' T-8^r5" 3'$" 3'- " ■ VAULTED CEILING V W j LIN. `� ROD & SHELF - M m - --- ------ - ----- VAULT - ---- APB( OF VAULT_ ii i i L `- l 20686F -- -r- - _� - „ _ 7'_g' iv WALL CABINETS c w BATH x `" g ' 0? � � O2�4-°V°ANJ. WW W m m U.~ ICC0L11 ■ HALL 2068 u� ■ I I NON-BRG rt•I3Arc�ILalrol i ` HEADER/CAMBER Y T-2" r' 4'4- 1'3'-6W In op 3 eo Ito 3 0 ROD & SHELF I I io T-9/„11 o 60686E START OF VAULT O68B " 6'_S3/n N N LIN.\ A •' /,..,'_'� ■ FOYER in e'-^'FIAT CEILING d 12'di" M V-6 N y 3 \I\/�a�/"/� " 7'-9tFin 3._2n Q DRYER rN �.... MAIN EGRESS DOOR ° 2'-10" TAW T-l" o BEDROOM #3 ■ ■ "� 6 r 8'-1'FLATCEILING BEDROOM # 4 J 4 09 ■ ■ at/rsra�� ■ O N� � 8'-1"FLAT CEILING 'np FE ' ■ fn 1 V-23/4" 2 0 '- 101-V o 9'-4"FLATCEILING AHU ■rn An WVAN.5'-10" 3-0" NRi ■ ■'.' ! ■ ■ ■ ■ ■ ■ ■ ■ t� T-10" ■' SH-W / EGRESS/ COL. _ _ _ _ _ _ _ _ _ _ SH-35 / EGRESS/ COL. STUCCO CEILING PER 57"p INSULATE WALL OWHSTRUCTURAL NOTES FR AMED AIG 3TAN w/ R-11 F/G GATT■. 4'-7" T-6tK" 4'4-4- 4'-T' 4'-4%" NON-BRG. WAL 50AMP T PANEL PROT GfION POST 7'-1^/," 13'-2%" - --- ' 22"X54"ATTI ACC. WHw DRIP PAN PULL DN. ST URS &D IN LINE ■ 18'-83/4" ■ N GARAGE -_. 8' 1"FLAT CEILING (A.F.F.) 4 N -------------1--------- ----- ---, I , y ■ I I S' 9 ■' I I I I V I I my I I I M I '•q I I I I I I I I ■' ■ ■ ■ ' 160701 OHGD Ir■ n 2'4" 16'-0" 2'.0" 321_011 20'-0" FPL METER UTILITY PAD PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. COVERED BY 19/32" 4 PLY CDX PLYWOOD (SEE NAILING DETAIL) HETA20 HURRICANE ANCHORS EMBEDDED 4" INTO BEAM FOR TRUSSES (PER CONN. SCHEDULE) FIBERGLASS SHINGLE ROOF OVER 30 # ROOFING FELT CONT ALUMN. MTL DRIP OVER (PT) 1 X 2 2" X 6" PRE -PRIMED SPRUCE FASCIA VENTED STUCCO SOFFIT (SEE DETAIL) STUCCO FINISH VERTICAL REBAR TIED TO DOWEL & RUNNING INTO BEAM BLOCK III s(:L.p "e .GW 3000 PSI CONC. VERTICAL DOWELS w/ 30" LAP SPLICE FROM FOOTER SEE FOUNDATION PLAN) FOR SIZE & SPACING ,I �.0''-0" TOP OF SLAB `Y GRADE 4" FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTD # J SF-1A5gj�14 Well # `p Date: 10 Reviewer: 0 4 . 12 6L,<� INSULATION 1/2" DRYWALL @ CEILING (TYPICAL) 8" X 8" X 16" BEAM BILK. W/ (1) # 5 BAR IN 3000 PSI CONCRETE FILLED CELL 8" PRECAST LINTELS W/ (1) # 5 BAR FOR ALL DOOR AND WINDOW OPENINGS & FILLED W/ 3000 PSI CONCRETE 1 "X 2" P.T. FURRING STRIPS a016" O.C. WITH FI-FOIL INSULATION 1/2" DRYWALL (TYPICAL) 8" CONCRETE BLOCKS WOOD BASE BOARDS 4" CONIC. SLAB (MIN. 2500 PSI) W/ 6 X 6 10/10 WWM OR FIBERMESH V TYPICAL WALL SECTION (CONCRETE BLOCK / LINTEL U-BLOCK CONSTRUCTION) NO SCALE FLOOR PLAN SCALE: 1/4" = 1'-0" AREA TABULATION OCCUPIED A/C AREA: 1728.0 SO. FT. GARAGE: 446.0 SQ. FT. FRONT ENTRY: 43.0 SO. FT. REAR PORCH: 83.0 SQ. FT. TOTAL FOOTPRINT: 2300.0 SQ. FT. SOFFIT DETAIL NO SCALE REVII CODE C% .dwgs° L mr ST. LUCIE COUI 2" X 6" PRIMED & PAINTED IRIS SPRUCE "o" x 22" SCREENED VENTS AT 48" O.C. ;TUCCO OVER WIRE LATH w/ 11ga. 2" NAILS WITH 318" HEAD DIA. AT 6" O.C. OVER 3/8" RIB LATH Q 6" O.C. WITH (2 LAYERS OF 15 # FELT OVER EACH FRAMING MEMBER) "REVISION - REVISION - - - 'O m G iLu w Y 0 LU x is w u T ` �.CENgC!S ZNo a '•�STA E OF .' EMI R BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. 11170878 I.LI I W 00 05 U Q Q M V) U. w 0 =UU) 0 ao w0 O li /' IL SHEET FLOOR PLAN PAGE MODEL FAIRFAX CUST DRAWN MARK MONTALTO JR DATE 03/12/2020 SCALE AS NOTED SHEET NO. 02 i OF 10_ ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS, GARAGE DOORS, AND SIMILAR ENVELOPE ELEMENTS. U OPENING AREA ZL INTERIOR ZONE Q END ZONE (NOTE #1) IN SQUARE FEET POSITIVE NEGATIVE POSITIVE NEGATIVE 7Q 10 +33.6 PSF -36.4 PSF +33.6 PSF •44.9 PSF 2Q 15 +33.5 PSF -36.3 PSF +33.5 PSF -44.8 PSF 3Q 20 +33.4 PSF -36.2 PSF +33.4 PSF -44.6 PSF a 25 +33.3 PSF -36.1 PSF +33.3 PSF -44.4 PSF s 30 +33.2 PSF -36.1 PSF +33.2 PSF -44.2 PSF s 35 +33.1 PSF -36.0 PSF +33.1 PSF -44.1 PSF 0 16 X 7 OHD +28.2 PSF -31.5 PSF 1. DESIGN PRESSURES PER ASCE 7-10 w 0 z EXPOSURE 160-C REVISION REVISION d s z m �i w a" so a � W G .,,H, O� • SE No.7087$ O x� ccc U F,SS10NA\, n,nuu,uu0n ENGINEER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 SHEET ELEVATIONS PAGE MODEL FAIRFAX COST. DRAWN MARK MONTALTO JR DATE 03/12/2020 SCALE AS NOTED SHEET NO. 03 OF 10 SHEETS WH ' 150 AMP _ FPL METER ` \ ELECT. PANEL ATTICACC ,i ELECTRICAL PLAN - SCALE: 1/4" = 1'-0" \ ■ ■ ELECTRICAL LOAD CALCULATIONS PER NEC 1 1728 SQ. FT. AT 3 VOLT-AMPERES (GENERAL LIGHTING) 5184 VA 2 (2) 20 AMP APPLIANCE CIRCUITS 3000 3 LAUNDRY CIRCUIT 1500 4 DRYER 5000 5 RANGE 12000 6 WATER HEATER 4500 7 DISHWASHER 1200 8 REFRIGERATOR 1200 9 IRRIGATION PUMP OPTION 1800 10 MISC. 5000 TOTAL: 40384 VA FIRST 10 KW @ 100% REMAINDER 0 40% TOTAL: A/C HEAT C& 100% TOTAL: 32153.6 = 133.97AMPS USE 150 AMP SERVICE. 240 10000 12153.6 22153.6 10000 32153.6 VA ELECTRICAL NOTES 1)ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2014 EDITION. 2)A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS ORA MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS) 3) RECESSED LIGHTING SHALL BE SEALED TO LIMITAIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4)SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP -ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FORALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FORALL 125-VOLT, SINGLE-PHASE 15 AND 20AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS. 9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. 3#1/0IN2"C ELECT. SERVICE "EP„ O150 120/240V M 2 j 1s MBR 150A MLO 3#1/0,#6,2"C # 6 CU GROUND TIED TO BUILDING STEEL, CWP AND DRIVEN GROUND ROUND OPTION - "A" ELECTRICAL RISER / DIST. NOTE: USE ALL COPPER WIRE NO SCALE REVIEWED FOR ; CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY REVISION REVISION z m Lu W Y C1 d x 0 70,37 -7 ATE OF i W ��1'QtIV'�'ER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 1 Lu CV W�U Q 0 M O _L0 �LLW Lu 0 m L) � CLo W0 � maw O oLL 0 Co w^ L.L M LO wIq M p w� M LL O J H n w a W Q J W ft U) W Z ry O ^ O N SHEET ELECTRICAL PAGE MODEL FAIRFAX OUST. DRAWN MARK MONTALTO JR DATE 04/09/2020 SCALE AS NOTED SHEET NO. 04 OF 10 SHEETS 9 m v !4 v 4'-3" 4'-0" FOOTER F-9 rYA"F 4" THICK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 67 V 10/10 W WM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL 4' THICK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR S"/ S' 10/10 W WM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL T o, rop4 o 4lo FOOTER F-9 _ a 4'-Tn fV 5,-3" 3'-2'/=" 7'-11/." 3'-11" 11'-8w, 7'•1'/4" 11'-83/8" 7-1,/" FOUNDATI"N PLAN N SCALE: 1/4" = 1'-0" 32'-0' 22'-10" I'-6" 3'-0" T-10" AA� , , I , , 5'-10" V-0" FOOTER F-9 [ --7 4_� R ,„ OE Is 9 E 3 11'-11%0 WH 0 e o C? g F_3 i') G N N N �xxC W g D. FTG N N N RECESS SLAB I --------------- BELOW FINISH FLOORI I - ---------------------------- I I I I I I � CURB HEIGHT VARIES AROUND PERIMETER OF GARAGE I I I I I I , I , , I I I I I 2'-0' 16'-O" 20'-0" e C0 io 'v a a v m a z Q h a 0 N1 O 07 J 5� LL N W AETER P O $ a 0 M a II- #5 REBAR FINISH FLOOR CONCRETE SLAB C M 4„ CONCRETE SLAB — — F. FLOOR ° '°— FINISH GRADE .— — — / ` N ,< e /° _ %, CO Z °} r 12" 1 z (2) # 5 REBAR (2) # 5 MINIMUM CONTINUOUS, CONTINUOUS N 16" 3" COVER MIMIMUM. BEARING FOOTING F2 INTERIOR NON-BRG. FTG. F1 SCALE: 112" = 1'-0" SCALE: 1/2" = 1'-0" III #5 REBAR Z IIII 7-5/8" CURB M- III REBAR CONCRETE SLAB ¢ - 4 cf) FINISH GRADE M r CONCRETE SLAB Z CONCRETE SLAB—( F. FLOOR �( i( , i° (2) # 5 MINIMUM CONTINUOUS, ' 16" 3" COVER MIMIMUM. (2) # 5 MINIMUM CONTINUOUS, 4„ 3" COVER MIMIMUM. F3 CURB SECTION STEP SCALE: 1/2" = 1'-0" (,,—:.6),�EXT�ERICIR SCALE: 1 /2'° = 1'-0'° REVISION i REVISION N r� 0 m F= f7 W Y U O� K W 6 1=j urn , SF �i TATE 0E ¢ 'nu""Hua„ BENCHMARK r ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 VJ W "00 W C5 U ® :Yi 0 J �, LL N n/ CD =UU) 0 0- 0 X v/ O o ul Co LL a { y FI 4 u) a f co # 5 REBAR WITH 30" MIN. LAP SPLICE ^- Q # 5 VERT. REBAR IN (3000 PSI) CONCRETE I I FILLED CELL. (SEE FOUNDATION PLAN FOR LOCATIONS) I I I h� -10 I I rzp fi� o # 6 REBAR WITH 30" MIN. LAP SPLICE I 6'X W FHA BLOCKWITH(1)# 5 BAR CONTINUOUS II I, , LL N # 5 VERT REBAR PSI CONCRETE BEND 5 BAR INTO SLAB +/-4' I I I= FILLED CELL. (SEEE FOUNDATION PLAN FOR LOCATIONS) I # 5 CONTINUOUS I STUCCO FINISH I r9 ® /W, U 4THICK CO CONIC. STUCCO FINISH E; w/ 6' X 6" 10/10 W.W.F. S" X W X 16" CONCRETE BLOCK (MASONRY) ° J S'XS' FHA BLOCK WITH (1)# 6 BAR CONTINUOUS ALL CELLS FILLED WITH (3000 PSI) CONCRETE '` - ." W 1S" FINISH GRADE ('SEE ELEVATION PLAN-) r 1 iH4 (n H S'XS'X CONCRETE BLOCK (MASONRY) ALL CELLS FILLED WITH (31D00 PSI) CONCRETE (2500 PSI) CONCRETE SPREAD FOOTING LL el - 7 - FINISH GRADE NIL i+ f`V - Tr (2)# 5 BARS CONTINUOUS lid111 (2500 PSI) CONCRETE SPREAD FOOTING IME # 5 BARS CONTINUOUS 16" z "6'(2) TYPICAL STEM WALL FOOTING DETAIL 10 TYPICAL STEM WALL FOOTING DETAIL F9 SCALE: V-0^ WED FOR scALE: v2" = r-a' CODE COMPLIANCE i Lu ST. LUCIE COUNTY f z BOCC ..,. O 0 t1 vJ N FILL COS 4'= N SHEET FOUNDATION PAGE MODEL FAIRFAX COST. DRAWN MARK MONTALTO JR DATE 04/09/2020 SCALE AS NOTED I SHEET NO. 05 OF 10 SHEETS f I L P,G. Hatch Legend 8'-1"A"F.F TRUSS END DETAIL 12 PLUMB CUT OVERHANG 8 4-3/16" HEEL HEIGHT 1,-0" TRUSS CONNECTOR SCHEDULE TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE ENGINEER., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 4) CONTRACTOR TO VERIFYALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 5) SEE TRUSS CONNECTOR SCHEDULE FOR TRUSS TO WALL CONNECTIONS CONTRACTOR: PSL PROPERTIES OWNER: PROP. GARCIA RES. TRUSS MFGR: BUILDERS FIRST SOURCE LAYOUT DATE: 03 / 30 / 2020 CUT -SHEET DATE: 03 / 30 / 2020 TRUSS ID BEARING POINT TRUSS ACTUAL UPLIFT CONNECTOR ID CONNECTOR UPLIFT DESIGN FASTENERS NOTES C5 1ST 1411 (1) HETA 20 1810 (8) 16d G1 1ST 2183 (2) HETA 20 2500 (12) 16d G1 2ND 2907 (1) - MGT 3965 (22) 10d & (1) 5/811 A.B. O2 O3 G3 & K3 CONT. 267 # PLF O HETA20 1810 (9) 10d X 1-1/2" SEE "GABLE END DETAIL" 1 STRAPAT EACH END AND 48" O.C. VALLEYS CONT 100 # PLF () MTS 16 1000 (14) 10d X 1-1/2" O 1 STRAPAT EACH END AND 24" Q.C. ALL OTHERS AT CBS BEARING EACH <1800 # (1) HETA 20 1810 (9) 10d X 1-1/2" AT CBS BEARING NOTE: FOR MISSED TRUSS CONNECTORS AT BLOCK WALLS WITH 1175 # UPLIFT OR LESS, PROVIDE "SIMPSON" HTSM WITH (4) 1/411 X 1-3/4" TITEN, AND (10) 10d. FOR MISSED TRUSS CONNECTORS FOR TRUSSES WITH 1175 # UPLIFT OR MORE, CONSULT ENGINEER FOR ADDITIONAL TRUSS CONNECTOR OPTIC VALLEY TRUSSES MAYBE ATTACHED WITH SIMPSON VTCR w/ (4) # 9SD X 2-1/2" TO SUPPORTING TRUSS AND (3) # 9 SD X 1-1/2" TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX. ® USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN. EMBEDMENT FOR ANCHOR BOLTS (A.B.) O(1) FGTR WITH (18) SDS 1/4"X 3" & (2) 1/2"X 5" TITEN HD MAYBE USED IN LIEU OF CONNECTORAS SPECIFIED. REVISION REVISION O z i CO t~t w W � Y v 2 ,"JI,IPlll ll,lp, Ill, 878 pIf- S E`�F-` �4 ifftNEER BENCHMARK ENGINEERING y BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 C W �co WrnU M _Lo LL W C� m U) 0 aW� LL U) maw O oCo LL i `r M to 0 Co a 0 O J LL F LLI F L) vo J O a Z R J J y- W Of ♦♦^^ VJ W Z � L.L (/i O ^ r o N SHEET TRUSS LAYOUT PAGE MODEL FAIRFAX COST. DRAWN MARK MONTALTO JR DATE 04/09/2020 SCALE AS NOTED SHEET NO. 08 OF 10 SHEETS O z z w a O It O ,/16" X 3" TAPCONS @ 12" O.C. (TYPICAL) •1/2" REDHEADS w/ 2" DIA. X 1/8" WASHER 4L) PT) OR 2" X 8" (PT) BUCK (TYPICAL) E FINISH FLOOR GARAGE DOOR JAMB ATTACHMENT TO CBS WALL (16'-0' X 8'-0" & 9'-0" X 8'-W GARAGE DOORS) 1. JAMBS: 2" X 6" OR 2" X 8" P.T. w/ 3/8" X 5-1/2" EMBED. TITEN HD w/ MIN. 2" DIA. X 1/8" WASHER. (TYPICAL) 2. HEAD: 2" X 6" OR 2" X 8" P.T. w/ 3/16" X 3" TAPCONS AT 12" O.C. 3. TORSION SPRING BLOCKING 2" X 6" P.T. w/ (4) 3/16" X 3" TAPCONS w/ 5/8" WASHERS. (STAGGER GRAIN) BATT INSULATION[ —TRUSS BOTTOM CHORD 1/2" DRYWALL CEILING NO SCALE 2" X 4" TOP PLATE OR 1-1/2" X 3-5/8" METAL RUNNER 2" X 4" WOOD FRAMING @ 24" O.G. OR 1-1/2" X 35/8" METAL STUDS 1/2" DRYWALL BOTH SIDES (TYPICAL ALL WALLS INCLUDING GARAGE) 2" X 4" BOTTOM PLAT OR 1-1/2" X 3-5/8" METAL RUNNER w/ TAPCONS OR CUT NAILS @ 2'-0" O.C. (10d NAILS FOR WOOD FLOOR) EXISTING FLOOR TYPICAL INTERIOR NON -BEARING WALL DETAIL NO SCALE >L EAVE � �� CORNER BAR (TYPICAL GENERIC ROOF PLAN "PLAN VIEW") A = 5 FEET ROOF SHEATHING ATTACHMENT REQUIREMENTS ZONE 1) NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE 0 NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE (3 NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD NOTE ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE. # 5 CORNER BAR WITH 30" MINIMUM OVERLAP # 5 VERT REINF. IN to FILLED CELL CONTINUOUS W TO FOOTINGS. Q CORNER BAR # 5 HORIZ REINF. TYP BLOCK TRANSITION NO SCALE (3) 16d NAILS (TYPICAL) CEILING PER PLAN 2"X4" SPRUCE OR BETTER LATERAL BRACE @ 6' O.C. FASTENED TO TOP OF BOTTOM CHORD OF TRUSSES WITH (2) 16d NAILS EACH, AT GABLE END TRUSS AND 4 TRUSS BACK P.T. 2" X 8" CONTINUOUS WITH 1/2" " J " BOLT OR 1/2" X 5-1/2" WEDGE ANCHOR AT 24" O.C. WITH 2" X 2" X 1/8" WASHERS GABLE EN C DETAIL NO SCALE 19/32" ROOF SHEATHING ROOFING UNDERLAYMENT PER PLAN 2"X4" "X" BRACING @ RIDGE AND 6' O.C. EACH SIDE OF RIDGE 2"X WOOD FASCIA WI ALUM. DRIP EDGE SOFFIT (SEE DETAIL) 2" X 4" LADDER FRAMING @ 12" O.C. 1/2" STUCCO EXPANSION JOINT STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" DIAMETER HEAD @ 6" O.C. OVER (2) LAYERS OF (15 # FELT OR TYVAK BUILDING WRAP) OVER 15/32" CDX PLYWOOD WITH 10d NAILS TO STUDS @ 6' O.C. PERIMETERAND FIELD. GABLE END TRUSS 16d COMMON NAILS @ 12" O.C. STRAP GABLE END TRUSS WITH "SIMPSON" HETA20AT48" O.C. WITH (9) 10d X 1-1/2" NAILS EMBED STRAP IN BEAM 4" NOTE: PROVIDE RAKE BEAM @ VAULTED GABLE ENDS TRUSS VERTICAL WEB REINFORCE EACH VERTICAL MEMBER OF GABLE END TRUSS WITH 2" X 4" T-BRACE WITH 16d NAILS AT 8 INCHES O.C. PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. COVERED BY 19/32" 4 PLY CDX PLYWOOD (SEE NAILING DETAIL) SIMPSON STRAP PER CONT. GALV. MTL DRIP OVER (PT) 1 X 2 2" X 6" RS SPRUCE FASCIA SOFFIT PER DETAIL TEXTURED STUCCO FINISH VERTICAL REBAR TIED TO DOWEL & RUNNING INTO BEAM BLOCK IN 3000 PSI CONC. (2) # 5 VERTICAL DOWELS w/ 30" LAP SPLICE FROM FOOTER PER PLAN CSEE FOUNDATION PLAN FOR SIZE & SPACING FOOTING F-1 12 6 EXTERIOR CEILING TO BE STUCCO OVER WIRELATH wl 11 GA. 2" NAILS w/ 3/8" DIA. 8" X 8" X 16" BEAM BLOCK \_W/ HEAD @ 6" O.C. OVER (1) # 5 BAR FILLED 3/8" METAL RIB LATH @ 6" W/ 3000 PSI CONCRETE O.C. w/ (2 LAYERS OF 15 # FELT OVER E*qp IEWED 8" PRECAST LINTELS FRAMEME I' W/ (1) # 5 BAR FILLED a. DE COMPLI W/ 3000 PSI CONCRETE ST. LUCIE COI i BOCC �TEXTURED STUCCO FINISH 16" X 8" CONCRETE BLOCK COLUMN FILE OR 8" X 16" CONCRETE CLOCK COLUMN CONCRETE SLAB /'PER FOUNDATION PLAN ENTRY POST DETAIL NOTE: SEE TYPICAL WALL SECTION FOR MORE INFORMATION NO SCALE REVISION REVISION $ 'm G W ,W� O Y W = .70878 * CJ F L ENGINEER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 ryN i e W � W 00 C V Q 0 L0 LL W LU 0 =VU) 0'_ 0 Oa(L QD�W 0- cof I M Ln O W Ch LJL p WUL LL L O� ry J � n 1..� F_ ix W ° Uw J J � W W z U) O d' N SHEET DETAILS PAGE MODEL FAIRFAX COST. DRAWN MARK MONTALTO JR DATE 04/09/2020 SCALE AS NOTED SHEET NO. 09 OF 10 SHEETS CMU W, (SEE W) CORRO: PER% APPLY PE BETWEE (SEE V cl FILLED CELLAT JAMB BLOCK (TYPICAL) I" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS. ANCHOR 1"X 4" P.T. (MIN.) BUCK WITH SEALANT PER WATERPROOFING NOTE # 4, AND ANCHORED TO MASONRY WITH 1-1/2" CASE HARDENED COIL NAILSAT 12" O.C. MAX. ANCHOR WINDOW FRAME TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCTAPPROVAL INSTALLATION REQUIREMENTS. WINDOW HEADER AND JAMBS TYPICAL BUCK DETAIL NO SCALE NOTE: TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/ MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. A IMP NOTE: WINDOW AND DOOR FENESTRATIONS IN ACCORDANCE WITH FBC R703.4 (1.2) AS PER DETAILS PROVIDED 3/4" NOTE:PRECAST CONCRETE I ND RESISTANT FLUSH SILL AS MANUFACTURED YCAST-CRETE (OR EQUAL) 1-3/8" PRECAST CONCRETE WINDOW SILL DETAIL NO SCALE STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 2 FILLED CELL AT JAMB BLOCK (TYPICAL) 1"X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS WOOD TRIM 1" X P. T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE # 4 AND ANCHORED TO MASONRY WITH 1-1/2" CASE HARDENED COIL NAILS @ 12" O.C. MAX SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB AND HEADER TO 1 x BUCKS IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 4 APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) NOTE: TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/ MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3. BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. CONTINUOUS FOAM INTERIOR AIR AND WATER SEALANT PER WATERPROOFING NOTE # 6 MARBLE SILL MORTAR OR GROUT 1/2" DRYWALL f_lII FILLED CELL AT JAMB BLOCK (TYPICAL) 1"X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS WOOD TRIM 2" X P. T WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE # 4 AND ANCHORED TO MASONRY WITH 1/4" TAPCONS w/ MIN. 1-1/4" EMBED. 3" FROM EDGES & 12" O.C. MAX. SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S INSTALLATION REQUIREMENTS. NOTE: BUCK 2"X 6" P.T. RIPPED DOWN TO 2 X 4-1/8" P. T. w/ 3/16" TAPCONS 1-1/4"MIN. EMB. 4/12"O.C. w/# 10 SCREWS, PER PRODUCTAPPROVAL. FASTENERS AS REQUIRED BY WINDOW MANUFACTURER CORROSION RESISTANT FLASHING PER WATERPROOFING (NOTE # 2) CAULK SEAM AT WINDOW INSTALLTION (SEE WATERPROOFING NOTE # 5) CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 } SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C.M.U. K7Lli13R.7I,Cc7i�>�fb��I`iI3�'i �__ WATERPROOFING NOTES: 1. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURE'S RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESISTANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECTION. ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. FBC R703.4AAAMA-714 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCKAND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 318" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. 4. PROVIDE PAN FLASHING AT THE SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILLAS WELL. PAN FLASHING SHALL BE CORROSION RESISTANT. (OPTIONAL, NOT REQUIRED) 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES ATALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR INSTALLATION. 6. AFTER WINDOW / DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE ENTIRE PERIMETER. 1 I�°�" I I vi LIJ co CL w 0) Q 0 M V) 0� � LL � LL Lu 0 =V� 0o �WLu LL U) ��w O mu - a. rn V ) M a) O) WRCT M N� L.L p W J LL. LL O� J � n W IL CU LL D J J � Of LLI Z O `� O N SHEET DETAILS PAGE MODEL FAIRFAX CUST. DRAWN MARK MONTALTO JR DATE 04/09/2020 SCALE AS NOTED SHEET NO. 10 OF 10 SHEETS pEvuloN REVISION d s z m t~t w W Y C1 � W LL = ``i��uuuu uun rV ,. H v 878 - R10P:\0�`. ss/ONAL EN`' ENGINEER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878