Loading...
HomeMy WebLinkAboutEnergy Code!!I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method P I 9 I Project Name: Gopher Tdge Rd (Gargia Res) Builder Name: Port St Lucie Properties Street: Gopher Ridge Rd Permit Office: S_ t Lucie County City, State, Zip: Fort Pierce , FL , 34982 Permit Number. Owner: Port St Lucie Properties Jurisdiction: 611000 Design Location: FL, Fort Pierce I County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1622.1 sqft.) Insulation Area 1 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1411.90 ft' b. Frame - Steel, Adjacent R=13.0 210.17 ft' 3. Number of units, if multiple family 1 c. NIA R= f 4. Number of Bedrooms 4 d. N/A R= ft: 10. Ceiling Types (1813.0 sqft.) Insulation Area 5. Is this a worst case? f- No a. Under Attic (Vented) R=30.0 1728.00, fF 6. Conditioned floor area above grade (M 1728 b. Knee Wall (Vented) R=30.0 85.00 fi' belov� 0 c. NIAucts R Conditioned floor area grade (ft� 11 R ft' 7. Windows(172.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 345.6 a. U-Factor: Dtil, U=0.58 111.38 f1 SHGC: SF GC=0.24 b. U-Factor. Dtil, U=0.55 40.00 ft' 12. Cooling systems kBtumr Efficiency SHGC SHGC=0.34 a. Central Unit 35.0 SEER:16.00 c. U-Factor. Dtil, U=0.38 21.40 ft' SHGC: SHGC=025 13_ Heating systems kBtulhr Efficiency d. U-Factor. NIP ft a. Electric Heat Pump 35.0 HSPF:9:00 SHGC: I Area Weighted Average Overhang Depth: 2.675 ft Area Weighted Average SHGC: 0.264 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1728.0 sgft.)II Insulation Area EF: 0.950 a. Slab -On -Grade Ede Insulation R=0.0 1728.00 tt' 9 b. Conservation features_ b. WA R= ft' None c. N/A R= fF 15. Credits CF, Pstat i Total Proposed Modified Loads: 56.28 Area: ASS Glass/Floor UAWr f Total Baseline Loads: 59.02 I hereby certify that the plans and specifications covered by Review of the plans and 0�'1;KE STg1F this calculation are in compliance with the Florida Energy specifications covered by this v Off, at Code. I calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 - ift I hereby certify that this building, a es' ed, is i mpli Florida Statutes. with the Florida Energy Code. �D WE'D OWNER/AG T ' BUILDING OFFICIAL. DATE:. del DATE: - Compliance requires certification. by the air handier unit manufacturer that the air handler enclosure qualifies - as ---certified factory -seals in accordance with R403.3.2.1: -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance wt h• R402 `41; 1 and this project req ru rps an i envelope leakage test re port with envelope leakage no greater than 5.00 ACH50 (14402.1 .1.2j: 1 JUN 229 2020 ' 4/62020 3:33 PM [ EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)-Compliant_ - `_ Page 1 pf 4 FORM R405-2017 I INPUT SUMMARY CHECKLIST RFPnRT w `I PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/E)dsting: Comment: Gopher Ridge User Port St Lucie 1 Port St Luoe St Lucie County 611000 Single -fame New (Fro i Rd (Gargia Res i Properties I Properties y Plans) Bedrooms: 4 Conditioned Area: 1728 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: Gopher Ridge Rd County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982 CLIMATE V Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low P BLOCKS Number Name Area Volume 1 Blockl { 1728 15033.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1728 15033.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Stab -On -Grade .Edge h Insulatio Main 199 ft 0 1728 fP — 0 0 1 ROOF / 1/ # Type Materials Roof Gable Roof Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip { Composition shingles 1933 ft' 0 W Light N 0.8 No 0.9 No 0 26.6 ATTIC v # Type i Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic + Vented 300 1728 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 F Under Attic Knee Wall (Vented) (Vented) Main 30. Blown Main 30 Blown 1728 f' 0.11 Wood 85 ft2 0.23 Wood 4/6/2020.3:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FnRM R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT ry I i WALLS FBelow Adjacent Cavity Width Height Sheathing Framing Solar mt Io-JAIaif Type Space R-Vaiup Ft In Ft In Area R-Value Fractien�sor Grad 1 N Exterior �oncrete Block - Int Insul Main 4.6999 35 0 8 1 282.9 ft' 0 0.600000 0 -2 N Exterior Concrete Block - Int Insul Main 4.0999 10 10 8 1 87.6 ft' 0 0.600000 0 3 NW Exterior 1 Concrete Block - Int Insul Main 4.0999 8 8 1 64.7 ft' 0 0.600000 0 _ 4 E Exterior Concrete Block - Int Insul Main 4.0999 47 5 8 1 383.3 ft' 0 0.600000 0 5 S Garage Frame - Steel Main 13 20 8 1 161.7 ft' 0.23 0.600000 0 _ 6 W Garage Frame - Steel Main 13 6 8 1 48.5 ft' 0.23 0.600000 0 _ 7 S Exterior Concrete Block - Int Insul Main 4.0999 32 8 1 258.7 fi' 0 0.600000 0 _ 8 W Exterior Concrete Block - Int Insul Main 4.0999 41 5 8 1 334.8 ft' 0 0.600000 0 DOORS # Omt { Door Type Space Storms U-Value eightln Area I Ft In Ft 1 S Insulated Main None .21 2 8 6 8 17.8 ft' 2 S Insulated Main None .21 3 6 8 20 ft' WINDOWS Orientation shown Is the entered, Proposed orientation. Wall } Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.58 0.24 Y 48.6 ft' 1 ft 0 in 1 ft 0 in None None 2 N 2 Metal Low-E Double Yes 0.55 0.34 Y 40.0 ft' 7 ft 0 in 1 ft0 in None None 3 NW 3 Metal Low-E Double Yes 6.58 024 Y 16A ft' 4 It 0 in 1 ft 0 in None None 4 E 4 Metal Low-E Double Yes 0.38 0.25 Y 18A It' 1 It 0 in 1 ft0 in None None 5 S 7 metal{ Low-E Double Yes 0.58 024 Y 46.4 ft' 1 ft0 in 1 ft 0 in None None 6 W 8 Metal Low-E Double Yes 0.38 025 Y 3.0 tt' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 446 f�• 446 ft' 64 ft 8.1 ft 1 f INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000276 1252.8 68.78 129.35 .099 5 HEATING SYSTEM # System Type Subtype Speed Efficiency .Capacity t Block Ducts 1 Electric Het'Pump/ None. Sing] HSPF:9 35 kBtu/hr 1 sys#1 4/6/2020 3:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 • I (I cnpnn PAnC_7n47 4 IMPI IT CI IMMARV f _1411=01tl 1ST RFPnRT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Alr Flow SHR Block Ducts 1 Central Unit! None Singl SEER:16 35 kBbAr 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None i. SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # v # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic i 6 345.6 ft Attic 86.4 ft' Default Leakage Garage (Default) (Default) 1 1 l TEMPERATURES Programabla Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan [[ jj Fib Mar Heatin(X] Jan [X] Feb Mar Apr [ r W May rlJun nJul Jun Jul IM Aug Aug Se SeP Oct Oct [ ] Nov [X] Nov [ ] Dec [X] Dec Vert [[ ]) Jan [[ J] Feb Mar EMay r eJun Jul Aug Se [X Oct [XJ Nov [ ] Dec Thermostat Schedule: HERS�2006 Reference Hours Schedule Type 1 2 3 4 . 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 P� 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 76 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (VVD) AM 65 65 65 65 65 65 65 68 68 68 68 68 P� 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WE H) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 .68. MASS Mass Type S Area Thickness Furniture Fraction Space Defaul 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 4/612020 3:33 PM EnergyrGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software { i i r Page 4 of 4 2017 EPL DISPLA ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The 11ower the Energy Performance Index, the more efficient the home. 1. New home or, ad 2. Single-family or r 3. No. of units (if mi 4. Number of bedro 5. Is this a worst ca 6. Conditioned floor 7. Windows, type a) U-factor.(w b) Solar Heat c) Area 8. Skylights a) U-factor.(w b) Solar Heat (yes/no) (sq. ft.) area ed average) Coefficient (SHGC) I 1. New (From Plans) 2. Single-family 3. 1 4. 4 5. No 6. 1728 7a. 0.548 7b. 0.264 7c. 172.8 ;d average) 8a. NA Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raisedl(R-value) c) Concrete, raised (R-valu_e) 10. Wall type and ins ulation: A. Exterior. 1. Wood frame �lnsulation R=value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type a a) Under attic b) Single ass( c) Knee walls, d) Radiant be *Label required by I certify that this saving features display card will Builder i - Address of New i� I4/6/2020 3:33:55 PM 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 13.0. 10B2. 12. Ducts, location & insulation level a) Supply ducts R 6.0 b) Return ducts R 6.0 c) AHU location Garage 13. Cooling system: Capacity 35.0 a) Split system SEER b) Single package SEER c) Ground/water source SEERICOP d) Room unit/PTAC EER ej Other 16.0 14. Heating system: Capacity 35.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 9.00 15. Water heating system a) Electric resistance EF ... 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit , HeatRec% g) Other 16. HVAC credits claimed (Performance Method) insulation level a) Ceiling fans Yes 11a. 36.0 b) Cross ventilation No Ay 11b. c) Whole house fan No Might walls 11c._ .. 30.0 d) Multizone cooling credit r installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes ection R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ie has complied with the Florida Building Code, Energy Conservation, through the above energy h will be installed (or ex ded) in this home before final inspection. Otherwise, a new EPL :ompleted based-Wi alled code-d npliant features. Date: /,"" A 2 U Gopher Ridne Rd City/FL Zip: _ Fort Pierce, FL 34982 EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edrlon (2017) Compriant Software Page 1 of 1 A Envelope Leakage Test Report (Blower Door Test), Residential Prescriptive, Performance or ERI Method Compliance 201.7 Florida Building Code, Energy Conservation, ft Edition Jurisdiction: 611000 Permit #: Job nforma Builder. Port & Lucie Properties Community: lot: NA Address: Gopher Ridge Rd City: Fort Pierce state: FL Zip: 34982 Air LeakaciI6 Ti6ttlkiiismitsftss ng Msql(s rOys fljqej either (h?Pqrft!mTqn(�0,, PTsPjpqm or ERf Method PkES d6iedipg Tair Re changes; -per hour at -a pressure of 0,2'jnch,v. Ifi-Climstd Zdhis I and 2, 0 PERFORMANCE or b ERI METHOD -The or dweWng unit shahe tested andivertfleo as.h0v1qj,q0 air Ipokqgq, rqjwof not,6xceedIng the selecled'A�.H(60) valu,e.'as 'shown Form R4101"17- (Pirlormifide).or kokOl 7. (ERI), section labeled as ACw. ,on A G H(50) specifiW on Fqr#n R405-2017-Energ k Ca c I' pal ance)crR406-2017.jERO.- 1 6.60 j x 60 s 15034- Method for calculating building volume: [ Building ACH(50) CFM(50) Volume 0 Retrieved from architectural plans PASS Code software calculated When ACH . �50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. L R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSMESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). 6onducte Testing shall be by either Individuals as defined In section 553.993(5) or (7), Florida Slatu6s.or individuals licensed as set forth in Section 489.105(3)(Q,.(g), or 6011'o an approved third party. A written report of the results of the test shali be signed by'the party'condu'cdng the test and provided to ttheowode official. Testing shall be performed at any time. after creation of all penetrations of the building thermal envelope. During testing: 1. Extedorwind I ows and.4 oors, fireplace and stove doors shall be closed, but not sealed, beyond.the Intended weath6rstripping or other infiltratidn control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond Intended Infiltration control measures. 3. Interior doors, if installe'd at the time of the test, shall be open. 4. Exterior doors for continuous Ve: nblation systems and heat'r . ecovery ventilators shall be closed and sealed. cooring 5. Heafin.g;)nd ririg coc ems, If installed at the time of the test, shall be turned off. 6. supply and return registers, If installed at the time of thetest, shall be fully open. Testing Company: Company Name: Phone: I.hdreby verify that It o above Air Leakage results are in accordance with the 2017 6th Edition Florida Building bode Energy Conservatiod: requirements according to the compliance method selected above. Signature of Teste Date of Test: Printed Name of ster Licensie/Certificati n Issuing Authority: 41642020 3.34:15 PM EnergyGaugdO USA 6.0.04 (Rev. 1) - Fla -Ries= i Fbd 6th Edition (2017) Compliant Software Page 1 of 1 Job #: Performed for: Gopher Ridge Rd (Gargia Res) 2401 sw Monterey Ln Port St Lucie, FI Sheet 1 Air Conditioning Unlimited Scale: 1 : 88 Page 1 Right -Suite® Universal 2019 19.0.08 RSU06570 2020-Apr-06 15:23:45 HVAC\Gopher Ridge Rd- Gargia.