HomeMy WebLinkAboutEngineers letterPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite #114 Port Saint Lucie, FL 34984 Phone (772) 785-9888 May 14, 2020 Re: Dock Structural Review 10301 S. Indian River Drive Fort Pierce, Florida To Whom It May Concern: Email pwelchinc@aol.com The structural plans for the proposed dock at the above -referenced address did not specify the details for the attachment of the center stringers to cross ties. For this dock the center stringers will be attached with 2" by 2" P.T. strap blocks with (2) - SS screws for each member. This method meets the design loads identified in the 2017 Florida Building Code (6 T" Edition). Thank you for your attention to this matter. Submitted by: PAUL ELCH INC. Paul W I h P. E. Fla Reg.,o. 29945