HomeMy WebLinkAboutIntegrity Metals 1 inch 2020RegulationNow
Busines's"I Professional
BCIS Home I log In ' user ReglstratioO =. Hot TOWS { Submit Surcharge ; Stats & Facts Pubiicauons Contact Us BCIS Site Map Links Search
ri �IU�
Product Approval
u.— Public user
Produn App'—al Menu > Product or APOhcat+on Search a Ajplfcation List > Application Detail
FL #
FL28113-RO
Application Type
New
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Integrity Metals LLC
Address/Phone/Ematl 2604 B Piper Drive
Vero Beach, FL 32960
(772) 584-2654
Admin@integritymetaisfl.com
Authorized Signature Joe Keene
Admin@integritymetalsfi.com
Technical Representative
Address/Phone/(mail
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Locke Bowden
the Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date
05/25/7023
Validated By
Diane Marotta, P.E.
m Validation Checklist - Hardcopy Received
Certificate of Independence FL�3 RQ CQS IntegriLok IM 10C - Min. 26GA Nailstrio Renort -
CS5.pdF
Referenced Standard and Year (of Standard) Standard Year
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option D
Date
Submitted
09/25/2018
Date
Validated
10/26/2018
Date
Pending FBC Approval
10/26/2018
Date
Approved
12/11/2018
Date
Revised
02/20/2020
Summary of Products
FL #
Model, Number or Name
Description
28113.1
IntegriLok IM100 - Min. 26GA Steel
IntegriLok IM100 - Min. 26GA Steel Nail Strip
Nail Strip
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
7: W^j1' Pf._F T_-'n F�riLok IM 100 - Min. 26GA Nailstrip
Approved for use outside HVHZ: Yes-__r'.=
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -SF
Created by Independent Third Party: Yes
Other: -86 PSF @ 10" Q.C. Install per manufacturer's
Evaluation Reports
details and in compliance with FBC 2017.
FI-28113 R0 AE IntegriLok IM 100 - Min. 26GA Nailstrip
Report - CSS.pdf
Created by Independent Third Parry: Yes
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1624
The State of Florida is an AA/EEO employer. copyright 2QQ7-24E3 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. It you do not want your e-mail address released in response to a public -records request, do not send electranic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section
455.275{1), Florida Statntes, effective October 1, 2012, IirEnsees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official cammunlcation with the licensee. However email addresses are public record. It you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here.
Product Approval Aooepts:
® eCe_
Credit Card
Safe
2460 B Piper Drive
I L-4 Vero Beach, Fl. 3
561-293-1407
INTEGRITYMETALS
Compliant with Florida Building Code 2017 (61fi ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant Active Quality Assurance Program
Product:
IntegriLok iM 100 Series - Min. 26GA Steel 1.0 Nailstrip Roof Panel FBC Sec.1507.4.2
Yield strength: 5oksi IV Coverage (Max.) Rib Height 7/S"
Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood
and plywood supports are outside the scope of this evaluation. Must be designed
in accordance w/ Florida Building Code 2017.
W penetration thru plywood supports 24" max. o.c.
Corrosion Resistant Compliant: FBC Sec. 1S07.4.3
Fastener; #10 x 1" fastener spaced @ 10" O.C.
Underlayment: To be compliant with FBC Sec.1507, Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
Install Details: Table A Allowable
Loads
Method 1:
DESIGN PRESSURE*
- 86 PSF
SPACING
10" O.C.
ADHEISIVE
EVERY OTHER NAIL SL OT IN THE NAIL FIN
Intertek Testing (TST-1S27)
Reference Data:
REPORT # 17726.054 50-44 RO** UL 580-06
*Design Pressure safety margin of 2.1
**This test report is owned by Quality Metal Roof Fabricators. integrity Metals has been given written
authorization by Quality Metal Roof Fabricators to shore testing_
certincate m inoepenoence:
Locke Bowden, P.E. does not have, nor will acquire a financial iriterest in any company manufacturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this
report. 't,11111frrrrr
6900.4
v10E1VS6
/ / = No
.49704
seal + a� sr TE or
ORION
.,���/pNA +1E�
Integrity Metals: IntegriLok IM 100 -Min. 26GA Steel 1.0 Nail Strip Panel
Installation Details
Limitations:
1. Underlayment to be compliance with current Florida Building Cade (FBC)2017 GTH ed.. see Chart 1507.1,1
2. Minimum slope to be compliant with Florida Building Code 2017 a ed., and per with Manufacturer's instaliatron reference.
3. Products are compliant with State of Florida product approval per RuLe 61G20-3. Compliance Method: 1-13
4. Engineering analysis for "project specific approval by local authorities wrurisdiction is allowed by other registered engineers-
S. Fire classification is not part of this acceptance_ Smear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6P ed , Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report_
PROFILE
lit 3/4„
�,44i'llff
♦4 E • 09, V ��0
•
7 , f
• * ' FASTENER PATTERN ALONG VERTICAL SEAM:
SfA� OF
P ,
�'.�,x�'. '0 LQ+O.C���� FASTENED LLD 5-1/4" U.C.
FAST94'W�KM46tf CORROSION RESISTANT COMPLIANT WrrH FBC 2016 SEC.1506.6 & SEC 1507.4.4
lid
16"
.a
..aa
z "_ff ZOO A,
2Mt
Timbodake Cove, LLC OnW E Eng. PE ant mebis
3324 W Univ Ave. ON FL PE L:- Na 81377 Rojmt FL 28113 Revision
Gamvft FL 326D7 FL CA Ur- W 33344 Data: 27Feb2U
v2r Vv< wa Page 1 of 1
Validation of Product Compliance
Prepared For
Integrity Metals, LLC (Client)
Integrity Metals, LLC, operating at 2604 Piper Dr_ Suite B, Vero Beach FL, has
submitted test reports and documentation for a revision to FL 28113, the IM100
IntegriLok metal roof panel.
This revision has been evaluated and validated by independent licensed engineers as
required by Rule fit G20-3 and is pending (final review and publication by the Florida
Building Commission. This revision includes additional test data for an installation
condition and maximum allowable uplift listed below:
Method B: 108.5psf I Use self -adhering underlayment and install fasteners in every
hole (+-5" o•c.). Factor of safety of 2.0 has been applied to calculate the allowable load
listed.
Compliance Statement:
This product, distributed under FL 28113 has been tested as required and has
demonstrated compliance with Florida Building Code 2017, Section 1504.3.2-
,l�1t�trtirrra���i
E•
%,1GENS, •.0 i
r�
2q retrT., Z.'.
No. 81377
Q7 TATE 0 �w1~
IONAL
David
Timberlake Cove, LLC
PE Lic. No- 81377
CA Lic_ No: 33344
Tim rtake
Cove