Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online 10 ` '. qa''�z` z*"'^,-.""'" x;r "' a,• ""a r.'a."'z x:�' M 'r��. �w 'Pw"., fad, M �C N'.t -9' u..�.. `r M° n �...r ,s': ro*#v,z #` '°w..,:,„,``rz `� ,.wn ."• ina' .. ��s �fi '�..,. '� =.t �.. 4� - •`_ '.�f` a. t ..&L�a.2— BCIS Home Log In ,l er Registration I Hot Topics bmi S rcharge f Stats&Facts Publications FBC Staff BCIS Site Map €. Links Search Ford a ST Lucie County, Perrn in_ � `Product Approval p .USER:Public User sds;ut- ;Tn , Product Aooroval Menu>Application Detail + +� FL# FL114O9-R9 4 Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived 5: as x, na?y= Product Manufacturer Regency Plus Incorporated Address/Phone/Email 2000 Locust Gap Highway Mount Carmel, PA 17851 (570)339-3374 tonyp@conservationwindows.com T'- Authorized Signature Tony Procopio Q"PIN- tonyp@conservationwindows.com � b Technical Representative Address/Phone/Email Nk _ ag Quality Assurance Representative Address/Phone/Email ,6 , Category Windows Subcategory Fixed 5 k x; Compliance Method Certification Mark or Listing di a Certification Agency National Accreditation &Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/NWWDA1O1/I.S.2 1997 AAMA/W.DMA/CSA 101/I.S.2/A44O 2005 ASTM E1886 2005 A £ a ASTM E1996 2002 y TAS 201 1994 TAS 202 1994 1 " 4 TAS 203 1994 41 r 4n Equivalence of Product Standards Certified By REVISWEDOR COU U l.V tthere are no changes in the new Florida Building Be%`;cAj https://www.floridabuilding.org/pr/pr_app_dtl.aspx?pazam�vGEVXQwtDgv8JyggZ9WuEBsxLzV2GSV&�xTICsKn4anR9J9xCgjYQCA%3d%3d[1/31/2018 12:47:01 Plvl) Florida Building Code Online Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No ON/A xr js ,1A as�n r FL11409 R9 COC Affirmation FL11409 417-0906 ss.pdf O § Product Approval Method Method 1 Option A a4 Date Submitted 01/04/2018 Date Validated 01/04/2018 Date Pending FBC Approval Date Approved 01/09/2018 F ' nm, r Summaiy of ProducCs _- b_ " �. FL'#' � •.,� Model,Number or Name- Description a = 11409.1 Series 3000/4000 Series 3000/4000 Non Impact Fixed Window r„ Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL11409 R9 C CAC NI006320-R6.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 t Design Pressure: +70/-70 Installation Instructions Other: FRAME MATERIAL TO BE RIGID PVC FROM ROYAL FL11409 R9 II 08-01380A.pdf E WINDOW AND DOOR PROFILES PLANT NUMBER 7 AAMA Verified By: Luis Roberto Lomas 62514 CERTIFIED(TPL-1). Created by Independent Third Party: Yes Evaluation Reports FL11409 R9 AE 511998B.pdf vTA € .*. Created by Independent Third Party:Yes f 11409.2 i' Series 5105 ,, Series5105 Impact,Fixed.Window, CertificLimits� - of Use ' ation Agency Certificate Approved for use in HVHZ:Yes FL11409 R9 C CAC NI006317A-R3.12 # Impa t Res sta t:Yesoutside HVHZ:Yes, 09ality Assurance Contract Expiration Date w�* P /30/2021 Design Pressure: +55/-55 Installation Instructions r �i < WINDOW FRAME MAT BE RIGID PVC F'PLANT NUMBER AAMA FL11409 R9 II 08-01381C.odf ¢ i B Li Roberto Lomas 214,-'A Verified y: Luis Ro e o o as 6 5 �� , " CERTIFIED'_(TPL-1), Created by Independent Third Party:'Yes Evaluation Reports FL11409_R9 AE 14042315 saflex.pdf' FL11409 R9 AE 511999D.pdf f .. CreatedbyIndependent7hird,Party:�Yes k � 11409.3 Series 5108 Series 5108 Vinyl Impact Rated Fixed Window " Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11409 R9 C CAC NI009490-R3.pdf m= Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +55/-55 Installation Instructions � 'P4'4 r Other: FRAME MATERIAL TO BE RIGID PVC FROM ROYAL FL11409 R9 II 08-01395C.12df WINDOW AND DOOR PROFILES PLANT NUMBER 7 AAMA Verified By: Luis Roberto Lomas 62514 CERTIFIED(TPL-1). Created by Independent Third Party: Yes Evaluation Reports FL11409 R9 AE 16111701PVB.pdf x' FL11409 R9 AE 512014C.pdf t d � Created by Independent Third Party: Yes 1 01 a Senes 511'0 Series=5110 Vinyl Fixed Window - — "� Limits of Use Certification Agency Certificate >e Approved for use;in HVHZ Yes FLU 1409 R9 C CAC NI011103 Rl.12cif Approved for use outside HVHZ Yes Quality Assurance Contract Expiration Date / i `Impact Resistant:Yes 0413012022 t fi t, "� Design`Pressure:+55/-65 Installation Instructions ! Other: FRAME MATERIAL TO BE RIGID PVC FROM ROYAL, FL11409 R9 II 08-01601B.pdf . ro WINDOW AND DOOR,PROFILES PLANT'N UMBER,7,AAMA, Verified By: Luis R. Lomas, P.E. 62514 �, CERTIFIED(TPL 1) Created by Independent Third Party Yes Evaluation Reports- L FL11409 R9 AE 16111701PV6 _ _.;_ ._ https:/hvww.floridabuilding.org/pr/pr_app_dtl.aspx7paratn=wGEVXQwtDgv8JyggZ9WuEBsxLzV2GSVfnxNCsKn4anR9J9xCgjYQCA%3d%3d[i/31/2018 12:47:01 PN] Florida Building Code Online FL11409 R9 ^AE 512258C pdf�� '> Created by Ihdependent Third Party Yes _ 1 _ 1409.5 Series 6613 Series 6613 Vinyl Fixed Window @"'> Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL11409 R9 C CAC NIO11688-R2.F1df as Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 10/31/2027 Design Pressure: +55/-55 Installation Instructions m Other: FRAME MATERIAL TO BE RIGID PVC FROM ROYAL FL11409 R9 II 08=02243B.pdf WINDOW AND DOOR PROFILES PLANT NUMBER 7 AAMA Verified By: Luis Roberto Lomas 62514 CERTIFIED(TPL-1). Created by Independent Third Party:Yes .,i Evaluation Reports FL11409 R9 AE 14091611 SG.pdf FL11409 R9 AE 512963B. df Create by In ep nd nt hir P y: Ye a� - -- — — te — — - — — s 11409"6 Senes 71'13,Fixed`Lite Window Series'7313 Fixed LitefWindow 74"x721';Non-Impact zzr Limits,of,Use Certification Agency Certificate t Approved for use,'In'HVHZ No FL11409 R9C CAC NI031585 R2. 1 ; ; Approved for use outside HVHZ Yes Quality Assurance Contract Expiration Date. Impact Resistant: NO 04/30/2027, { aX z Design Pressure. +50 0/-50 0 Installation Instructions Other 'FL11409 .R9 II 08-02617_ d�f Verified By: Luis Roberto Lomas 62514 I Created by Independent'Third Party:,Yes Evaluation Reports F L11409`R9 AE 513396. ddff Created by Independent Third Party.Yes NON �gF k i bY€�yY" 4E Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 a The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.:;Privacy Statement::Accessibility Statement::Refund Statement � �s i Nzti za Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to apublic-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here._ 6 v a� product Approval Accepts: z tA EM 91 N REM k @� E Credd�ar17 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratnwGEVXQwtDgv8JygqZ9WuEBsxLzV2GSVfixNCsKn4anR9J9xCgjYQCA%3d%3d[1/31/2018 12:47:OI PNj L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville,NC 27023 Report No.: 512963B 434-688-0609 rllomas@lrlomaspe.com Manufacturer: Regency Plus, Inc. 2000 Locust Gap Highway Mt. Carmel, PA 17851 Product Line: Series 6613 Vinyl Fixed Window-96"x 48" Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a).The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-02243 Revision B,prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: NCTL 110-16563-1 signed and sealed by Robert H Zeiders P.E. National Certified Testing Laboratories,York, PA TAS 201-94 Large Missile Impact Test, Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure, ±55.Opsf design pressure, 8.25psf water penetration. TAS 203-94 Cyclic Pressure loading±55.Opsf design pressure 3. Report No.: NCTL 110-16563-2 signed and sealed by Robert H Zeiders P.E. National Certified Testing Laboratories,York, PA ASTM El886-05 and ASTM E1996-02/06/09 ASTM El886/El996 Large Missile Impact, Level D,Wind Zone 4 ASTM E1886/E1996 Cyclic Load Test,±55.Opsf design pressure 4. Report No.: NCTL 110-16563-3 signed and sealed by Robert H Zeiders P.E. National Certified Testing Laboratories,York, PA AAMANVDMA/CSA 101/I.S.2/A440-05/08/11 Design pressure: ±55.Opsf Water penetration resistance 8.35psf 5. Anchor calculations, report number 512963-1A,prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±55.Opsf • Maximum unit size: 96"x 48" • Units must be glazed per ASTM El300-04/09,see installation instructions for glass details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be rigid PVC. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-02243 Revision B. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). \���� x. *� 0 51 1 r�o , TAT 'OF001 P T ION, • . • G%\ IONAL E`\N 1 of 1 Luis R. Lomas, P.E. FL No.:62514 02/20/2017 RENSIONS REV DESCRIPTION DATE APPROVE. A ADDED EDGE DIMENSIONS 03/02/15 R.L. 96" MAX FRAME WIDTH B REVISED GLASS DETALS 01/25/17 R.L. F24� -{ DAX D.C. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 48" 4) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN MAX HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. FRAME 5) FRAME MATERIAL: EXTRUDED RIGID PVC. HEGHT6) UNITS MUST BE GLAZED PER ASTM E1300-04 09 SEE SHEET 1 FOR GLASS DETAILS. 7) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 8) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9) FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 10) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS 6613 VINYL FIXED WINDOW SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. EXTERIOR VIEW 11) FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. DESIGN PRESSURE RATING IMPACTRATING LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. LARGE 12) ALL FASTENERS TO BE CORROSION RESISTANT. +55.OPSF MISSILE IMPACT 13) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH MISSILE LEVEL D,WIND ZONE 4 AND HVHZ STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 7/8" FU=30KSI .048" THICK MINIMUM 1/8" ANN 14) GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN THIS 0.090" SENTRY GLAS SHEET BY KURARAY SIGNED:0112612017 1/8" ANN 5/32'TEMP REGENCY PLUS, INC. \���u11II11ri�� DESICCANT STEEL 2000 LOCUST GAP HIGHWAY EXTERIOR SPACER MT. CARMEL. PA 17851 SYSTEM SERIES 6613 VINYL FIXED WINDOW =* 0 5 9/16" BITE INTERIOR 96" X 48" ELEVATION, ANCHORING AND NOTES STATE OF a:—. SIKAFLEX GLAZING DETAIL TABLE OF CONTENTS DRAWN: Dwo ND. 08-02243 RB ' 552 SHEET N0. DESCRIPTION SCALE NTS °A� 10/23/13 SN�1 OF 4 ,. ///O SEALANT i ELEVATION, ANCHORING AND NOTES L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 2 — 4 1 INSTALLATION DETAILS 434-688-0609 rllomas@lrlomaspe.wm REIASIONS REV DESCRIPTION DATE APPROVE. 1/2" MIN. A ADDED EDGE DIMENSIONS 03/02/15 R.L. EDGE DISTANCE B REVISED GLASS DETAILS 01/25/17 R.L. WOOD FRAMING OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT 1 3/8" MIN. 1/4" MAX. APPROVED EMBEDMENT SHIM SPACE SEALANT QQ❑ 1/4" MAX. SHIM SPACE 1/2" MIN. n D EDGE DISTANCE �LJJ #10 WOOD SCREW INTERIOR g10 wooD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS �d J Li EXTERIOR APPROVED INTERIOR SEALANT EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION I` #10 WOOD u SCREW NOTES: APPROVED 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SEALANT Q❑ 1/4" MAX. NOT SHOWN FOR CLARITY. SHIM SPACE 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 WOOD FRAMING 1 3/8" MIN. SIGNED:0112612017 OR 2X BUCK EMBEDMENT BY OTHERS 2000 GEOCUSTNCY PGAPSHIGHWAY ` Ert0til9ii�� 1/2" MIN. MT. CARMEL, PA 17851 `v,•�\G NSq EDGE DISTANCE SERIES 6613 VINYL FIXED WINDOW —*• 0,6125 *• VERTICAL CROSS SECTION 96" X 48" `_ WOOD FRAMING OR2X BUCK INSTALLATION INSTALLATION DETAILS ��6`" STATE OF 1/j i�iP••!c V.LN: DWG No. 08-02243 RB ii/FS. OR1 DRAW , 0 SCALE NTS DATE 10/23/13 sHEET2 OF 4 'A7L�/QNAl1E��\\ L ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC27023 FL No.: 62514 434-686-0609 Alamas@Irlamaspe.wm RENSIONS REV DESCRIPTION DATE AP VED 3/4" MIN. A ADDED EDGE DIMENSIONS 03/02/15 L. METAL EDGE DISTANCE STRUCTURE 6 REVISED GLASS DETAILS 01/25 R.L. OTHERS APPROVED �O q SEALANT 1/4" MAX. Q SHIM SPACE 1/4" MAX. nn SHIM SPACE LJ D #10 SMS OR LLLLJJJJ SELF DRILLING n� CREW 3/4" MIN. IILJIr EDGE DISTANCE Q � INTERIOR #10 SMS OR SELF DRILLING SCREWS METAL EXTERIOR INTERIOR STRUCTURE U BY OTHERS a EXTERIOR XTERIOR SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION #10 SMS OR SELF DRILLING SCREW APPROVED QO NOTES: SEALANT 1.INTERIOR AND ERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLA SHIM SPACE 2.PERIMETER AND JOIN ALANTBY OTHERS TOBE METAL —� DESIGNED IN ACCORDANCE ASTME2112 STRUCTURE SIGNED:0112612017 BY OTHERS FI EDGE DISTANCE 2000 EOCUSTNCY PGAP HIGNCAY x\�S\IR`IIL,O �!/,� V TICAL CROSS SECTION MT. CARMEL, PA 17851 v•�\GENS�9Si�- METAL STRUCTURE INSTALLATION SERIES 6613 VINYL FIXED WINDOW *• 0 96lx 136" X 48" INSTALLATION DETAILS STATE OF :` .� DRAWN: OWG NO. REV "':c�ORIV.G�`'- V.L. 08-02243 B �(/Y •NAI E�\\�, SCALE NTS DATE 10/23/13 ISHEET3 OF 4 L.ROBERTO LOMAS P.E. Luis R. Lomas E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-688-0609 rromas@lrlomaspe.com 2 1/2" MIN. —�{ REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY A ADDED EDGE DIMENSIONS 03/02/15 R.L. BY OTHERS .4 1 . a TAILS 01/25/17 R.L. ..a ° 1 1/4" MIN. OPTIONAL1X BUCK ° a° - a'°' a EMBEDMENT 1 1/4" MIN. TO BE PROPERLY SECURED T EMBEDMENT SEE NOTE 3 SHEET 1 CONCRETE/MASONRY BY OTHERS ' 9 APPROVED q oc 1/4" MAX. SEALANT Qa� 1/4 MAX' OPTIONAL 1X BUCK SHIM SPACE Q SHIM SPACE TO BE PROPERLY SECURED n SEE NOTE 3 SHEET 1 I1 D 3/16" TAPCON a LLLLJJJJ 3/16" TAPCON n e' IILaJII INTERIOR 2 1/2" EXTERIOR INTERIOR MIN. EDGE DISTANCE O APPROVED EXTERIOR SEALANT 3/t s" TAPCON JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION APPROVED NOTES: SEALANT 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. Q° 1/4" MAX. 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE OPTIONAL 1X BUCK SHIM SPACE DESIGNED IN ACCORDANCE WITH ASTM E2112 TO BE PROPERLY 0 SECURED SIGNED:0112612017 SEE NOTE 3 SHEET 1 T CONCRETE/MASONRY ° a 200o EocusrNCY Pc PsHICHwAY \\�xA 1Rt(t0'-/J BY OTHERS a 1 1/4" MIN. MT. CARMEL, PA 17851 a^ EMBEDMENT C v F ° ° SERIES 6613 VINYL FIXED WINDOW * FT ' ' 96" X 48"INSTALLATIONDETAILS ' OF w 2 1/2" MIN. I DRAWN: DWG N0. REV //� ♦ QRIEDGE D VERTICAL CROSS SECTION E ""111 scALe DnrE 08 SOEE243 B %SS/��A`I�tJG\��� CONCRETE/MASONRYINSTALLATION NTS 10/23/13 Q OF 4 L.ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-688-0609 rllomasOalrlomaspe.com