Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
MIAMI•DADE MIAMI—DADE COUNTY R8111MA PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION ---- — (786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NO F" �`� �? {{�� www.miamidade.gov/buildine Regency Plus,Inc. AUG ® L., H 2000 Locust Gap Highway Mount Carmel,PA 17851 L . Lucie County,,Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction.RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"5000"White PVC Single Hung Window-L.M.I. APPROVAL DOCUMENT: Drawing No. RPLS0062, titled "Series 5000 Vinyl Single Hung Window - LMI", sheets 1 through 10 of 10, dated 01/12/09, with revision K dated 05/13/20, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J.Amoruso, P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for tennination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followe by the expiration date may be displayed in advertising literature. If any portion i it shall be done in its entirety. ((++ INSPECTION:A copy of this entire NOA shall be provided to the user byllie an u actureerr dis and shall be available for inspection at the job site at the request of the BuilCG7,Of Q 1 This NOA revises and renews NOA No. 18-0911.05 and consists of this page 1 and evi t,as E-1, E-2,E-3 and E-4,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.20-0526.04 MIAMI•DADE COUNTYM Expiration Date: July 22,2025 Approval Date: July 02,2020 T6/26/20 Page I Regency Plus,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Letter from manufacturer requesting a 1-year extension to allow time to perform verification test, dated 06/11/18, signed by Tony Procopio,Plant Manager. (Submitted under NOA No. 18-0911.05) 2. Testing agreement letter dated 06/12/18 between National Certified Testing Laboratories (NCTL) and Regency Plus, Inc., issued by NCTL and signed by Justin L. Bupp, Laboratory Manager. (Submitted under NOA No. 18-0911.05) 3. Statement letter of conformance,complying with FBC 6"Edition (2017), dated January 8, 2018,prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso, P.E. (Submitted under NOA No. 18-0122.13) 4. Laboratory addendum letters in the Test Report No. NTCL-110-11537-1, issued by National Certified Testing Laboratories, dated 03/31/09 and 05/01/09, both signed and sealed by Harold E. Rupp,P.E. (Submitted under NOA No. 08-1210.13) 5. Laboratory compliance letter in the Test Report No. NTCL-110-11537-1, issued by National Certified Testing Laboratories, dated 08/18/08, signed and sealed by Harold E. Rupp, P.E. (Submitted under NOA No. 08-1210.13) G. OTHERS 1. Notice of Acceptance No. 18-0122.13, issued to Regency Plus, Inc. for their Series "5000"White PVC Single Hung Window—L.M.I., approved on 03/08/18 and expiring on 07/22/19. 2. This is a one-year approval, subjected to successful verification test. Manuel PerdP.E.Product Control ExNOA No.20-Expiration Date: July 2 Approval Date: July 02,2020 E-2 Regency Plus,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 5 2 issued to Kurara America Inc. for their 1. Notice of Acceptance No. 19 030 .0 ss y , "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 2. Notice of Acceptance No. 18-0122.02, issued to ENERGI Fenestration Solutions USA,Inc., for their White Rigid PVC Exterior Extrusions for Windows and Doors, approved on 03/08/18, expiring on 02/28/23. F. STATEMENTS 1. Statement letter of conformance,complying with FBC 61h Edition (2017), and of no financial interest, dated May 15, 2020,prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso,P.E. 2. Proposal No. 19-0312 issued to Regency Plus, Inc. by the Product Control Section, dated May 15, 2019, signed by Manuel Perez, P.E. G. OTHERS 1. Notice of Acceptance No. 18-0911.05, issued to Regency Plus, Inc. for their Series "5000"White PVC Horizontal Sliding Window—L.M.I., approved on 10/11/18 and expiring on 07/22/20. 2. This is a one-year approval, subjected to successful verification test. Manuel Perez,P.E. Product Control Ex i er NOA No.20-0 26.0 Expiration Date: July 22, 25 Approval Date: July 02,2020 E-4 Q Q � SERIES 5000 VINYL SINGLE HUNG WINDOW INSTALLATION INTO WOOD SUBSTRATE (WOOD OR TAPPING W SCREWS) OR CONCRETE/MASONRY SUBSTRATEo 52"MAX.FRAME (CONCRETE SCREWS) LL w WIDTH a K- O 355 w' ¢ zLL F a a` gg ao g 46 q w" �� � D.L.O.WIDTH p 3"FROM CORNERS Y @ HEAD&SILL TYP. C tv 13 a"O.C.MAX.TYP.WOOD 6"FROM JAMB 4 CORNERS TYP. o a N LL SCREWS ° 124"O.C.MAX.TYP. 2"O.C.TYP.FOR w CONCRETE SCREWS WOOD SCREWS. 0� w 4"O.C.TYP.FOR ¢ z 33 4"D.L.O. D O O CONCRETE SCREWS. �F 75"MAX.HEIGHT 5 5 z zo ..m FRAME �� �� d=a a=� >m Z x 3 HEIGHT �Meeting Rail °J w(J9-p Z j mU N� B 2"O.C. Uj L)< Z J r E 32 T"SASH E 4 36 TYP.EACH SIDE D w �zn M e" D.L.O. 5 5 SASH OF MEETING RAIL 8 g o o¢ $" HEIGHT HEIGHT C % a oo X // 8 x / 8 INSTALLATION NOTES: NF 1 s a 1. HEAD AND SILL ul 8 ANCHORAGE THE SAME. Nw g w 2. JAMB ANCHORAGE SAME. 4 153, A 'O.C.TYP. g 3, +/-1"TOLERANCE ON `OR" @ HEAD&SILL ANCHOR LOCATION. - DETAIL 1 3.1. TAPCON MINIMUM (SEE SHEET 5) Rod J.Amoroso,P.E. 45�"SASH SERIES 5000 VINYL SINGLE HUNG WINDOW SPACING IS 4"OC. Florionda P.E.No.49752 D.L.O.WIDTH EXTERIOR VIEW-ANCHORAGE 3.2. WOOD AND TAPPING 1111111I180 SPACING IS PE N oa 49"SASH WOOD AND CONCRETE/MASONRYSOBSTRATESMINIMUM E 2"OC. �J`�0��V F %9G Q; No 49752 WIDTH �• SERIES 5000 VINYL SINGLE HUNG WINDOW O: STATE OF EXTERIOR VIEW WEEP HOLES: ,�O ... E;��``� DESIGN PRESSURE RATING(PSF) IMPACT RATING 1. ONE(1)WEEP HOLE MEASURING 1-1/4"X 1/4"AND EMPLOYING A PLASTIC WEEP COVER WAS LOCATED AT 2-5/8"FROM EACH END OF THE EXTERIOR SILL FACE. PRODUCT g REVISED LARGE MISSILE 6u0arneieodawith the Florida +55.0/-55.0 IMPACT Row No. 20A526.04 Ea tra6on Daeo 7I2212o25 Dy: Mmnn ado Produe�-Go tral Q Q � SEE GLAZING o 820 DETAIL 2, 21 SEE GLAZING SHEET 10 16 o N a DETAIL 1, 2 10 12 43 $ 19 SHEET 10 15 50 3 20 3 wa 0r� _E 12 21 6 13 a aN wLL ad ❑ 14 1 © 14 20 Y 23 18 INTERIOR� 15 EXTERIOR p m 5 16 12 16 o 1 16 N n u 3 O �o q 23 18 SEE GLAZING o�- ; �p �Qo DETAIL 1, i Oz. D� SHEET 10 3��0 zm-OIL OOO z_0�Z g m u; EXTERIOR INTERIOR Y y3: Q0 gm z (L Ur Z V m VERTICAL SECTION VERTICAL SECTION z �� m A SILL-COMPONENT ID MEETING RAILS-COMPONENT ID o >W ; s W J F Z w m g 6g N wog>< 9z _ c oU P� OH m�@j5 W> - ms oao INTERIOR o Jr� EXTERIOR N ` m Q .. Robert J.Amoroso.P.E. Flodda P.E.No.49752 1 D �° �!+{�ES Q 19 4 �QQ���GENgF 09G 20 No 49752 SEE GLAZING 9 DETAIL 2, 11 SHEET 10 STbTE OF :+� VERTICAL SECTION HEAD-COMPONENT ID PRODUCT gREVISED Bulldln P111 9 with the Florida NOA-No.Ode 20.0526.04' e.ghotlon Dace- 7I2212025 F- - Mlam ado Produo-troi" Q Q � K K PROPERLY SECURED 1X 1/4" ITW TAPCON #12 OR #14 WOOD SCREW 51 PROPERLY SECURED 1X m w WOOD BUCK BY OTHERS 52 INSTALLATION INSTALLATION ANCHOR ANCHOR WOOD BUCK BY OTHERS (SEE NOTE 3, SHT. 1) (SEE NOTE 2, SHT. 1) 1 1/2" MIN. #14 WS: 1" MIN. EDGE DIST. w WOOD BUCK PROTECTION BY v 2X WOOD OTHERS (SEE NOTE 3, SHEET 1) EDGE DIST. #12 WS: 7/8" MIN. EDGE DIST. �w BY OTHERS to SHEATHING (SEE NOTE 2, SHT. 1) w z d D LL CONCRETE BY OTHERS v v 1 1/2" MIN. BY OTHERS (SEE NOTE 2, SHT. 1) v EMBEDMENT ¢ w EXTERIOR FINISH 't #14 WS: 1 1/2" MIN. EMBEDMENT ° wg aw 1/4" MAX. BY OTHERS #12 WS: 1 3/8" MIN. EMBEDMENT ` r In?• ( SHIM SPACE 1/4" MAX. Y EXTERIOR FINISH _SHIM SPACE BY OTHERS w PERIMETER CAULK Qo BY OTHERS D� TER CAULK N° Q D PERIMETER OTHERS QO �p a z a o n xto > z EXTERIOR 'co a Q.w EL( JJZ B VERTICAL SECTION Z�W 65 N N �� CONCRETE SUBSTRATE INTERIOR INTERIOR w U U J o E N HIEIGHT VERTICAL SECTION T WINDOW W O F Z EXTERIOR WOOD SUBSTRATE HEIGHT �o >w B 0 0� �'eLL Sz N oU oa- Co U) w O - 0 OR—TO—SUBSTRATE m¢ANCHOR—TO—SUBSTRATE $ EDGE DISTANCES ARE n �� S 4 TYPICAL AND m MEASURED TO BOTH SIDES OF SUBSTRATE a a Robert J.A No. P.E. Florida P.E..No.49752 � C= � \Islllpfpf,,q � ��•``�\�AW.ES. PERIMETER CAULK �0 �••�GENS �9 BY OTHERS 1/4" MAX. 1/4" MAX. �00, b F_SHIM SPACE SHIM SPACE Qj NZV PERIMETER CAULK EXTERIOR FINISHBY OTHERS14 WS: 1 1/2 MIN. EMBEDMENT E j11�,BY OTHERS ` e %, #12 WS: 1 3/8" MIN. EMBEDMENT CONCRETE BY OTHERS a 1 1/2" MIN. 9�;• ESTATE OF .:� (SEE NOTE 2, SHT, 1) EMBEDMENT '•............ p R jl \? EXTERIIORO FINISHTHERS {et ��,�,S+S PROPERLY SECURED 1X JAL WOOD BUCK BY OTHERS 2X WOOD (SEE NOTE 3, SHT. 1) SHEATHING BY OTHERS BY OTHERS 14 ITW" TAPCON 52 1 1/2 MIN. (SEE NOTE 2, SHT. 1) WOOD BUCK PROTECTION / EDGE DIST. #14 WS: 1" MIN. EDGE DIST. PRODUCT REVISED BY OTHERS (SEE NOTE 3, INSTALLATION ANCHOR #12 WS: 7/8" MIN. EDGE DIST. PROPERLY SECURED 1X plin with the Florida SHEET 1) WOOD BUCK BY OTHERS NOA-No.Oda 20-0526.04 #12 OR #14 WOOD SCREW 51 (SEE NOTE 2, SHT. 1) E.i.at Dae"• 712212025 VERTICAL SECTION INSTALLATION ANCHOR BY`�rA, CONCRETESUBSTRATE A VERTICALSECTION miam ads Prods t"""l WOOD SUBSTRATE a 1/4" MAX. 2X WOOD SHIM SPACE o n FRAME BY OTHERS m 1/4" MAX. SHIM SPACE 1 1/2" MIN. EMBEDMENT — CONCRETE c (SEE NOTE 2, SHT. 1) INTERIOR SHIM AS REQUIRED 1" MIN. EMBEDMENT — MASONRY m $ o� �m ro OT 14 WS: 1 1 2" MIN. EMBEDMENT @# / 52 1/4" ITW TAPCON INSTALLATION ANCHOR w'o �� w N � #12 WS: 1 3/8" MIN. EMBEDMENT a w LL 0. .o MIN. EDGE DISTANCE - CONC. w #12 OR #14 WOOD SCREW 61 0� �d o� Q� V 2" MIN. EDGE DISTANCE - MASONRY INSTALLATION ANCHOR 1 �—CONCRETE OR MASONRY Lu Y ?. #14 WS: 1" MIN. EDGE DIST. o� �� V BY OTHERS #12 WS: 7/8" MIN. EDGE DIST. q -V V (SEE NOTE 2, SHT. 1) g m Q. = a N a .Q PROPERLY SECURED 1X z a m Do WOOD BUCK BY OTHERS a PROPERLY SECURED 1X (SEE NOTE 3, SHT. 1) p o WOOD BUCK BY OTHERS (SEE NOTE 2, SHT. 1) �d d� WOOD BUCK PROTECTION BY ¢ z� :1 OTHERS (SEE NOTE 3, SHEET 1) "�`) SHEATHING EXTERIOR '� BY OTHERS z zu) EXTERIOR FINISH ai= z EXTERIOR FINISH PERIMETER CAULK PERIMETER CAUL BY OTHERS ¢a ww $ w BY OTHERS BY OTHERS BY OTHERS }0 w CJ7� vNnz ^ C VERTICAL SECTION a o > w WOOD SUBSTRATE ANCHOR-TO-SUBSTRATE D VERTICAL SECTION �zo -e„ EDGE DISTANCES ARE CONCRETE(AIASONRY g >a TYPICAL AND SUBSTRATE N o ��LLt. MEASURED TO BOTH �w m �Q 1/4" MAX. SHIM SPACE SIDES OF SUBSTRATE �Z 9�2 INTERIOR SHIM AS REQUIRED w o a^a � �QWLL #14 SHEET METAL w °o SCREW/SELF-DRILLING SCREW e 3 °a INSTALLATION ANCHOR Robert J.Amoruso,P.E. Florida P.E.No,49752 EDGE/DIST.I(TYP.) LOWER SASH SIMILAR ����Q��;cEjys;4o,P.,� -� INSTALLATION FOR o`b�•`' F •:Gs 3 THREADS MIN. UPPER FIXED LITE JAMBS. m No 49752.. o EMBEDMENT BEYOND INTERIOR WALL - �J�� •� METAL SUBSTRATE BY OTHERS STATE OF /7! p (SEE NOTE 2, SHT. 1) O e�Fsi•.�O RFlags lls d EXTERIOR FINISH PRODUCT REVISED PERIMETER CAULK BY OTHERS as vt�li with tho Floritla saricO°ins o BY OTHERS NDA- o. 20.0526.04 E.Ii.11ntlon DaWL0712212025 VERTICAL SECTION METAL SUBSTRATE mlam aao vroea Sao trot a a Series 5000 Single Hung/Bill of Material of 0: them No. Description I Part Numbers ISupplier Material or Note op Fmme Com onents "� 1 MasterFrame NWhlta 7780 Energi/Royal White PVC(2) 'n 2 Impost Mullion Fixed Center Section(Fixed Meeting Rail) N White 106317735 Energi/Royal White PVC(2) 1/2"GLASS BITE 3 Sash Frame(Operating Sash) N White 128217750 Energi/Royal White PVC(2) w = 4 Sash Slop Frame Cover Head IV White 107017736 Energl/Royal White PVC(2) 7 7/8"O.A.LAMINATED GLASS LL m 5 Sloped Sill IV White1161l7738 EnergilRoyal White PVC(2) 19 INTERIOR CONSISTING OF:EXTERIOR UJ ww wS 6 GlazingLiRrall Handle(Operating Sashes) TV White 106817747 Energi/Royal White PVC(2) / — LAMINATED GLASS-(2)NOMINAL a z ¢N w 7 Glazing Bead Stop(Operating Sashes) N White 106717745 Energl/Royal White PVC(2) 1 4 \ 1/8"ANNEALED GLASS W/0.090" w LL a w° 8 Interlock Cover(Operating Sashes IV White118o/7727 Ene iiRo al White PVC z \ KURARAYAMERICA INC.TROSIFOL h 9 Pock et Insert IFlxed Center Section NWhife1079,7737 Eno ilRo al White PVC(2) INTERLAYER,7/16"AIRSPACE W/ ' 10 Glazin Bead Fixed Center Section /Fixed Meetin Rail NWhite 1080/7753 Ene I/Ro al White PVC 2 I y 11 Glazin Bead Fixed Center Section NWhite1103/7726 EnergllRoyal White 2 ` STAINLESS STEEL SPACER(TYPE Reinforcement SS-D),INTERIOR 118"TEMPERED Opbar GLASS erating Sash I Lock Sash/Impact Lock Top&Bottom 1 Heavy \ o 12 ST-226-144-0.052 Hygrede Metals .06"Galy.(1) Re o 0 0 13 Ira oat Mullion(Fixed Meeting Raiq ST-888-168-0.062 Hygmda Metals .05"Galy.1) 14 #6x518"TeklSashReinforcementFastener 117595 GLF Corporation �� / EXTERIOR a o WeatherstrippingGLAZING DETAIL 1 'N ^g �� 15 .210 x.300 Fin Seal Pocket Cover W23303NW0000 Ultra-Fab OQ 5 r 16 .200 x.340 H-Bulb Seal Sash Frame E20718WN2020 Ultra-Fab 3 OPERATING SASH JAMB SHOWN. } Cluj c 8 17 .187x.300FinSealInterlockCover W23301NW0000 uera-Fah SAME AT HEAD AND SILL. i g, 18 .27G x.220 Fin Seal Sash Frame 1 Single Leg Screen Frame WI1225TW0000 Ultra-Fab U 2 m(7 Z Glazing 1-Z— m N 19 Wet Glaze O eratin Sash 552 Sikeflex Black Sika US Oj S 4=g -ae Z Y 20 O emtin Lock Sash E366 2.7mm I0.9.0 PVB Inteda IG Hunieane Laminate Ira act Cardinal j<D-W od 20 Fixed Kee erSash E3662.7mml0.9.0 PVB Interia erlG Hurricane Laminate Impact Cardinal a(,W 05 S 21 Glass SettingBlocks Sash 2NB-8K-0.125-032-064 Frank Lowe U N M Z o a: 22 ENDUR IG with XL Edge SS S acer(SS-0TYPE) — Cardinal Stainless Steel / \ 9 W� to< 1 F Screen Components(not all components ID'ed in section views) � 0 UU U}w O N 8 m 23 Single Leg Frame New White 08516NEW192 Sha es Unlimited 1 INTERIOR W o r=Z Q gg 24 Double Le Fmme New White 06515NEW192 Sha es Unlimited / 1 1 0 o 2 25 TensionSprings 2584 Ade t N LL (7 d 3002606 19 I 26 Fiberglass Screen Cloth Charcoal!60"x 96' Phifer w �Q 27 Screen Spline H/ EX-FLX-0165-BK Imperial Plastic USA I W t oo g s 28 Aluminum Comer Keys CK252X260 I Hy mde Metals !Y m m m Misc.Components,Hardware and Hardware Fasteners(not all components ID'ed in section views / 1/2" GLASS BITE w 8 " to a o w 29 Weep Hole Cover White H-808WHZ Produet Design O w m 30 Push Guides White/Screen Frame H-H707WHZ ProductDesl It EXTERIOR \ m 31 Interlock Cover O emtin Sash)/Look Sash HH-66 Vinyl Cement RH Products \ a 2 32 29 lb.3 Cog 1984 Series I onstant Force Balance 803829 Amesbury/Truth \ - 33 LiRrall End Caps White 00156-000I S.I.L.Plastic / Robert J.Amoroso,P.E. 34 Stainless Steel Staples 318 x 12 Sash BEA 80MO Smith Staple — 7/8"O.A.LAMINATED GLASS Florida RE No.49752 35 30PP12411950.9/16 X1 318 X 3 Foam Block W0511022 Lindenme r 36 .75 While Salanee Plu 21300-00077 Lamat SPN ek 22 CONSISTING OF:EXTERIOR "111111111j" 37 Hurricane GradeS rin CS025 James s rin Wire LAMINATED GLASS-(2)NOMINAL ..........�� DAMES 38 Accessory Parts installation Translucent 02-MX015001GC2 Novagard Silicones 1/8"ANNEALED GLASS W/0.090" ��`�P•�,��ENs�c•�9G Used to secure O: •rP 39 Hurricane Tilt Latch IOSTA-003-EW Vision Industries operating sash to KURARAY AMERICA INC. 7No 49752 •• masterrmme. TROSIFOL INTERLAYER,7/16" 40 Safe Seal Lock 3220SS-003£N Vision Industries AIRSPACE W/STAINLESS STEEL 41 safe seal Kee er 8292A-003-EW Vision Industries SPACER(TYPE SS-D),INTERIOR STATE OF :'� 4z CAM Type Sweea o Head 3220 Vision Industries 1/8"TEMPERED GLASS . �'�•••'�lP--- OR 43 CAM T e Sweep Lock 3220SS-003-EW Truth Hardware (�••.• 1'D• 44 05132"Trl-Rlvet.0401276 Grip/Sash Pivot Bars 1120D3 GLF Corporation ��ItS'�O ..... �% 45 1118.18 x 0.850 Flat Wafer Shoulder[Sash/Hurricane Latch 137341 GLF Corporation GLAZING DETAIL 2 ''��EEEEIE�►��`` 46 #8 x 1 1/4"Tek White If Locks 120376 GLF Corporation 47 #6 x 1"Tek White[Keepers 116821 GLF Corporation FIXED LITE HEAD SHOWN.SAME .. 48 #8 x 3!4'Tek/Pan Head Balance Shoes 120766 GLF Corporation AT SILL AND JAMBS.SILL 49 111 x3"Flat/Installation Screws 401168 GLF Co omtion PRODUCT REVISED 50 Face Mounted Keeper steel Truth Hardware GLAZING BEAD IS ITEM NO.10. pi Ing with the Florida Installation Fasteners NOA N9 bode NOA-No. 20.0526.04 51 012 OR 014 WOOD SCREW n/a n/a Steel Ex Iration Date: 7/2212025 52 1/4"ADVANCED THREAOFORM TAPCON nla ITW Seel Is 53 #14 SHEET METAL OR SELF-DRILLING SCREW n/a We Steel NllamfjDode Prod,aGe trot 11)Nygrade Metals Spedfration:AISI 1005 to 1010,CS Type A and B,30 ksl to 50 ksl Yield Strength,G40 Galvanized 12)ENERGI FENESTRATION SOLUTIONS USA,INC.,PER CURRENT WAMI-DADE NOTICE OF ACCEPTANCE(NOA).