HomeMy WebLinkAboutMiami Dade NOA Approval - R PanelsDEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NCI Group, Inc. 14031 West Hardy Houston, TX 77060 SCOPE: MIA.MI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 vvww.miamidade0fm economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction AHJ)e I This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: `R-Panels" 22 ga. & 24 ga. Structural Galvalume Steel 14/4" x 36" Roof Panels APPROVAL DOCUMENT: Drawing # R95, titled "PBR Panel Flashing Detail", sheets 100 through 110, prepared by NCI Group, Inc., dated March 21, 2018, signed and sealed by Mark Detwiler, P.E., on March 21, 2018, bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TEl�:MINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. TheNOAnumberprecededbythewordsMiami ADVERTISEMENT:. -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. be done in its entirety. If any portion of the NOA is displayed, then it shall INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the lob site at the request of the Building Official. bmitted pages E-1, E-2, E-3, E44) & NOA No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 Page 1 NCI Group, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 96-0529.03 A. DRAWINGS 1. Title Number: Signature: Date: Revision Date: B. TESTS 1. Laboratory Number Type: Signature 2. Laboratory Number Type: Signature: 3 . Laboratory Number Type: Signature: 4. Laboratory Number Type: Signature: 5. Laboratory: Number: Type: Signature: 6. Laboratory: Number: Type: Signature: "R-Panel" Roof Panel R95, sheets 100 through 110 Terrence E. Wolfe, P.E. OS/23/96 O l/3 0/97 Farabaugh Engineering and testing, Inc. T103-96, dated 01/18/96. Uniform static air pressure loading, per ASTM 1592 (22 ga FISM Panel) Daniel G. Farabaugh, P.E. Farabaugh Engineering and testing, Inc. T102-96, dated 01/11/96 Uniform static air pressure loading, per ASTM 1592 (24 ga R- Panel) Daniel G. Farabaugh, P.E. Farabaugh Engineering and testing, Inc. T 104-96, dated O 1/OS/96 Large missile impacts, per PA 201-94 (24 ga R-Panel) Daniel G. Farabaugh, P.E. Farabaugh Engineering and testing, Inc. T 118-965 dated 04/26/96 Susceptibility to leakage for class 1 metal roof panel, per "FM 4471-G" (24 ga R-Panel) Daniel G. Farabaugh, P.E. West Penn Testing Laboratories, Inc. WP-9048 (Report # 034), dated O1/31/96 Tensile Strength (22 ga R-Panel) Todd A. Ault West Penn Testing Laboratories, Inc. WP-9048 (Report # 034), dated O1/31/96 Tensile Strength (22 ga and 24 ga R-Panels) Todd A. Ault E-1 Helmy A. Makar, Product Control Section Supervisor NOA No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 NCI Group, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 7. Laboratory: Number: Type S lgnature : CALCULATIONS 1. Title: Signature: Date: Center For Applied Engineering, Inc. MTS No. 257558, dated 03/27/96 Wind Driven Rain Test per PA 100-95 (24 ga R-Panels) R. G. Miller, P.E. 22 gage and 24 gage R-Panel Terrence E. Wolfe, P.E. OS/23/96 EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 99-0823.04 DRAWINGS TESTS CALCULATIONS MATERIAL CERTIFICATIONS STATEMENTS 1. Letter requesting renewal of NOA No. 96-0529.03 and stating that the product has not changed, dated August 12, 1999, signed by BIlan 0 EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 02-1016.04 DRAWINGS 1. None. CALCULATIONS E-2 elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 NCI Group, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. MATERIAL CERTIFICATIONS 1. None. 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 08-0212.06 A. DRAWINGS B. TESTS 1. Test report on Large Missile Impact Test, Cyclic Wind Pressure Test, and Uniform Static Air Pressure Test on R-Panel 24 ga. X 36" wide, prepared by Farabaugh Engineering and Testing Inc., Report No. T216-07, dated 0611512007, signed and sealed by Patrick J. Farabaugh, P. E. and Daniel G. Farabaugh, P. E. 2. Test report on Uniform Static Air Pressure Test on PRB-Panel 22 ga. X 36" wide, per ASTM 1592-01, prepared by Force Engineering & Testing Inc., Report No. 07- 0004T-08A, B, dated 0112812008, signed and sealed by Terrence E. Wolfe, P.E. 3. Test report on Uniform Static Air Pressure Test on PRB-Panel 22 ga. X 36" wide, per ASTM 1592-01, prepared by Force Engineering & Testing Inc., Report No. 07- 0004T-08C, dated 0112812008, signed and sealed by Terrence E. Wolfe, P. E. 4. Test report on Uniform Static Air Pressure Test on PRB-Panel 24 ga. X 36" wide, per ASTM 1592-01, prepared by Force Engineering & Testing Inc., Report No. 07- 0004T-08D, E, dated 0112812008, signed and sealed by Terrence E. Wolfe, P.E. 5. Test report on Uniform Static Air Pressure Test on PRB-Panel 24 ga. X 36" wide, per ASTM 1592-01, prepared by Force Engineering & Testing Inc., Report No. 07- 0004T-08F, dated 0112812008, signed and sealed by Terrence E. Wolfe, P. E. 6.. Test procedure for wind and wind driven rain resistance of discontinuous roof systems performance for R-Panel Steel Roof 3 6 " wide x 24 ga. Per TAS 10045, test report # T351-07, dated 12120107, signed and sealed by Daniel G. Farabaugh, P. E. C. CALCULATIONS D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. Tensile Test foe 22 ga. From test # 07-0004T-08A, B. 2. Tensile Test foe 24 ga. From test # 07-0004T-08A, B. Helmy A. Makar, P.E., M.S. Product Control Section Supervisor IN OA No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 E-3 NCI Group, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 11-0810.07 DRAWINGS 1. DI "Vving with no number, prepared by NCI Group, Detwiler, P. E., on July 2 7, TESTS 1. None. CALCULATIONS 1. None. titled "PBR Panel Flashing Detail ", sheets 1 through 11, Inc., dated July 27, 2011, signed and sealed by Mark 2011. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Permitting, Environment, and Regulatory Affairs. MATERIAL CERTIFICATIONS 1. None. OTHERS 1. Bill of Sale, assignment and Assumption Agt�eement. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 12-0730.02 DRAWINGS 1. Drawing # R95, titledPanel Flashing prepared by NCI Group, Inc., dated July 02, Detwiler, P.E., on July 02, 2012. TESTS 1. None. CALCULATIONS 1. None. Detail ", sheets 100 though 110, 2012, signed and sealed by Mask D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS elmy A. Makar, P.E., M.S. Product Control Section Supervisor IN No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 NCI Group, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 7. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 15-0505.26 A. DRAWINGS 1. Drawing # R95, tite'fled "PBR Panel Flash ing prepared by NCI Group, Inc., dated April 14, Detwiler, P.E., on April 14, 2016. B. TESTS C. CALCULATIONS Detail " sheets 100 through , 110, 2016, signed and sealed by Mark D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS S. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing # R95, titled "PBR Panel Flashing prepared by NCI Group, Inc., dated March 21, Detwiler, P.E., on March 21, 2018. B. TESTS C. CALCULATIONS Detail ", sheets 100 through 110, 2018, signed and sealed by Mark D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS F. STATEMENTS 1. FBC, 2017 Edition Compliance Letter prepared by NCI Group, Inc., dated March 21, 2018, signed and sealed by Mark Detwiler, P.E., on March 21, 2018. elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-0920.04 Expiration Date: 02/27/2023 Approval Date: 05/10/2018 E-5