Loading...
HomeMy WebLinkAboutBuilding PlansCONSTRUCTION BY PORT ST LUCIE PROPERTIES 2401 SW MONTEREY LANE, PORT ST LUCIE, FLORIDA, 34953 MODEL: (772) 336-0050 CONSTRUCTION OFFICE: (772) 249-0089 WWW. PORTSTL UCIECUSTOMPROPERTI ES. COM DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE PROJECT NAME: PROPOSED WILSON RES. OCCUPANCY TYPE : R STREETADDRESS : 594 BEACHAVE., PORT ST. LUCIE FL 34952 CONSTRUCTION TYPE: V PERMIT NUMBER: CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL POSITION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY THE ST LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. FLORIDA BUILDING CODE: 2017 EDITION WITH: X SUPPLEMENTS AND ASCE 7 -10 2- STRUCTURE DESIGNED AS :ENCLOSED: X PARTIALLY ENCLOSED: OPEN BUILDING: 3. RISK CATEGORY : I II X III IV EXPOSURE CATEGORY: B C X D 4. DESIGN WIND VELOCITY: 160 MPH 124 ASD NIA LRFD END ZONE WIDTH : 5' 5. MEAN ROOF HEIGHT: 11.5' ROOF PITCH: 6112 PARAPET: N/A FT. 6. COMPONENTS & CLADDING WIND PRESSURES USED: (PSF, BASED ON 10 SQ. FT. @ 10'MRH) + 20.5 + 20.5 + 20.5 + 35.5 + 35.5 + 22.3 ZONE 1: ZONE 2: ZONE 3: ZONE 4: ZONE 5: GARAGE: _ 32.5 _ 54.9 - 80.7 - 38.5 _ 44.6 _ 29.0 7. DESIGN LOADS: FLOOR: 40 PSF ROOF / DEAD: 5 PSF ROOF/LIVE: 20 PSF BALCONY • NSA PSF DOCK: NIA PSF DECK : NIA PSF STAIRS : NIA PSF FENCE: N/A PSF RAILING- NIA PLF / CONCENTRATED 8. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE: YES X NO (NOT APPLICABLE EXPLAIN WHY NOT) 9. IS A CONTINUOUS LOAD PATH PROVIDED: X YES (NOT APPLICABLE EXPLAIN WHY NOT) 10. DESIGN SOIL BEARING PRESSURE: 2000 PSF SOIL TEST REPORTS SUBMITTED? YES AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CEERTIFICATION IS TRU AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME: BOWDOIN G. HUTCHINSON, RE CERT. # & CO. CERT. AUTH. 70878 DESIGN FIRM: BENCHMARK ENGINEERING DATE: ADDRESS: 2001 SWPSL BLVD UNIT 104, PORT ST LUCIE, FL 34984 PROPOSED WILSON RESIDENCE 594 BEACH AVE. PORT ST. LUCIE, FL. 34982 MIN IBM a - PLANS AND ENGINEERING BY BENCHMARK ENGINEERING "1111111111111"' G• T "'o 4 � � 7 87 c 0 . to Z= S T 10 FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS #56-7-4-4,1071 9 & Well # Date: Reviewer: ST LUCIE COUNTY, FLORIDA TPLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING &REGULATIONS DIVISION PRODUCT REWEWAFF/DAVIT BUILDING PERMIT NUMBER: OWNERSNAME: PROPPSED WILSON RES. APPLICANT: PRODUCT ONIN DESIGN PPERESSG URES PRODUCT RATED DESIGN PRESSURES MANUFACTURER MODELNUMBER PRODUCT APPROVAL NUMBER GLASS TYPE METHOD OF ATTACHMENT WINDOWS SEEELEVATIONS +/-55.0 MI WINDOWS & DOORS 185 SH FL#17499.1 IMPACT 3/18'X1-1/4'MM. EMBEDTAPCONS AT2'1WO.C. YIRNDOWS WA N/A WA WA N/A N/A N/A MULLIONS WA BLOCK GLASS N/A N/A WA WA NIA N/A N/A SKYLIGHTS N/A N/A N/A N/A N/A N/A N/A DOOR-B SEE ELEVATIONS +/- 67 THERMA-TRU SMOOTH STAR FL # 20468.1 NIA 1/4' X 1 W TIN. +MBBEC TAPCONS DOOR-G SEE ELEVATIONS +/-55.0 MI WINDOWS & DOORS 120/1301140 S.G.D. FL#22401.3 IMPACT (2-ROWS) 1/4' X 1-1/4' MIN. EMBED TAPCONSAT W/16'O.C. GARAGE DOORS SEE ELEVATIONS +33.0/-42.0 CLOPAY 33w6-22 FL#16548.4 N/A S/16"XMdWMIN.EMBED LAG SCREW ONE PER BRACE HURRICANE PROTECTION N/A N/A WA N/A N/A N/A INA ROOF VENTILATION N/A N/A TAMCO-COOL RIDGE CM - 18531 FL # 4103.1 N/A FASTEN USING MIN. CAW SHANK Del, MIN. 0.41m Dw. HEAD. MIN. 2,W' LONG OCRROE EITHERSIDEOFROORDG E SLOT ONTOHE O.C.ON ERHER SIDE OF THE RIDGE BLOT ONTO SHEATHING ROOFING MATERIALS 1w 194 OWENS CORNING ARCH. ASPHALT SHINGLE FL#10674.1 N/A FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS STEEL, AWMBIUM OR COPPER ROOFING MUS•MINIMUM 12 GAUGE (0.1 W INCH (BMM) SHANK WITHA MINIMUM SIB INCH (18NM) DIAMETER HEAD, ASTM F 1867, OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND A MINIMUM X4INCH (INAM) INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN BMINCH(1,W)THICK, THE FASTENERS SHALL PENETRATE THROUGH THE sHF� HmGFAs ENERssHAucoMmvw mAmn F1887 NOTE: (S PER S TAB) I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, AND HAVE APPROVED THEIR USE IN THIS STRUCTURE TO PROVIDE ADEQUATE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. NAME: BOWDOIN G HUTCHINSON, P.E. SIGNATURE: ON PLAN DESIGN PROFESSIONAL: BENCHMARK ENGINEERING CERTIFICATION NO. 70878 GENERAL NOTES 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFYALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4)ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 201T PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2014 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVYTERMITE INFESTATION AREA PER FRC 301. ENERGY CONSERVATION NOTES 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017 ENERGY CONSERVATION RESIDENTIAL. 2)ATTICACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENTTO THE INSULATION ON THE SURROUNDING SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. 3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMITAIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. 4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3. 5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH FBC 2017 ENERGY CONSERVATION R401.3. ELECTRICAL NOTES 1)ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2014 EDITION. 2)A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS) 3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4) SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP -ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FORALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OFANY SINK. 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS. 9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. ADDITIONAL NOTES 1) INTERIOR TO 5E W DRYWALL FINISH. 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. W THICK WITH (13 GAGE, 1 3/8" LONG,19/64" HEAD; 0.098" DIAMETER, 1 %' LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 5/64" HEAD; OR GYPSUM BOARD NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWERAREAS. (PER FRC 702A.1 & FRC 702.42). 4) WALLAND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5) WALLAND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6)ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE ACRITICAL ^� RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM !(J PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3"BEAMS: 1 IWSUSPENDED SLABS: 1 ''A" 6) LAP ALL REINFORCING STEEL MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEE MINIMUM IN BEAMS AND COLUMNS. 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES 10) UNLESS OTHERWISE NOTED, FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 11) LINTELS SHALL HAVE A MINIMUM 4" BEARING. 12) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 13) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 318" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32" COX PLYWOOD WITH 10D NAILS TO STUDS Q 6" O.C. PERIMETERAND FIELD. 14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. J w w x w O U z z 0 � z z LU z L) IW aD j O Z LU of (jw za Z 0 W LU 1 0 lu 0 In PLAN SHEET INDEX COVER SHEET 1 SHEET 2 FLOOR PLAN SHEET 3 ELEVATIONS SHEET 4 ELECTRICAL SHEET 5 FOUNDATION SHEET 6 BLOCK PLAN SHEET 7 14VAC PLAN SHEET 8 TRUSS PLAN SHEET 9 DETAILS SHEET 10 DETAILS SHEET 11 SHEET 12 PLAN SHEET INDEX 15'-1 "TO RIDGE 11'-4"M.R.H. BRG. HT. 8'-1" 19' LINEAR FEET OF SCALE: 1/4" = V-0" 3I NOTE: 31 SAND FLOAT FINISH ON ALL STUCCO BANDS & RETURNS SUCHAS WINDOWS, DOORS, GARAGE DOORS, AND ENTRY FF.E.0'-0"_-_- ■', 12 6 OPENING LD. H_ 31 SCALE: 1/4" = V-0" ENING 1.1 A 11 OPENING I.D. OPENIFNG I.D. 31 11 Nm BEARING HT. W-1 mnnm 1111111111 nnnnn nnnnn nnnnn FINISHED FLOOR 0�-O" A-� nnnnn r......I v vrrr _BRG. HT. 8'-1'_ -- -F.F.E. F.F.E. 0'-0" 12 �6 OPENING I.D. E 3E BRG. HT. W-1" F.F.E. 0'-0" SCALE: 1/4" = T-0" BRG. HT. V-1" F.F.E. 0'-0" SCALE: 1/4" = V-0" ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS, GARAGE DOORS, AND SIMILAR ENVELOPE ELEMENTS. O OPENINGAREA A INTERIOR ZONE END ZONE (NOTE #1) IN SQUARE FEET POSITIVE NEGATIVE POSITIVE NEGATIVE iQ 10 +33.6 PSF -36.4 PSF +33.6 PSF -44.9 PSF 2 15 +33.5 PSF -36.3 PSF +33.5 PSF -44.8 PSF Q 20 +33.4 PSF -36.2 PSF +33.4 PSF -44.6 PSF aQ 25 +33.3 PSF -36.1 PSF +33.3 PSF -44.4 PSF 5 30 +33.2 PSF -36.1 PSF +33.2 PSF -44.2 PSF 0 35 +33.1 PSF -36.0 PSF +33.1 PSF -44.1 PSF Q 16 X 7 OHD +28.2 PSF -31.5 PSF 1. DESIGN PRESSURES PER ASCE 7--10 fij z EXPOSURE 160-C 11 CALCULATE ATTIC VENTILATION CEILING = 1765 SQUARE FEET 1755/300= 5.85 REQUIRED VENTILATION 184.0 LINEAR FEET OF 6" X 22- VENTS @ 72" O.C. = 28.11 SQ. FT. / 2 = 14.1 SQUARE FEET AVAILABLE FOR CROSS VENTILATION. 14.1 SQUARE FEET> 6.0 SQUARE FEET: SOFFIT VENTILATION OK PROVIDE 6'X 22" SOFFIT VENTS A 72" ON CENTER REQUIRED VENTING IN THE UPPER PORTION OF THE ATTIC 40 - 50 % OF REQUIRED VENTING AS PER FRC 806.2 EX #2 5.850 X 40%" = 2.340 SQ. FT OF RIDGE VENT 5.850 X 50% = 2.926 SQ. FT OF RIDGE VENT RIDGE VENT 19 LINEAR FEET OF COOL RIDGE VENT (18 SQ. IN. / FT.) = 2.375 S.F. OF RIDGE VENT PROVIDE 19 LF OF RIDGE VENT BRG. HT. 8'-l" F.F.E. 0'-0" - BRG. HT. F-l" F.F.E. 0'-0" REVIEWED 11. , • 1 w FILE C0I I REl!IS,ION REVISION I z m c� IL V nui IN o l : Z = * AT OF 0- 1 k, BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 i {k I uj Z Ill . 0 O Q co = Ili Lu i¢?�_ W m . O cy) cf) X LL d� a I dL M W WIT M 0 W J LL rmmm L J h W 0 LLI Z Q - W ♦ L) W ~ Z 0 cn l P CD N G SHEET ELEVATIONS PAGE OY MODEL ARUBA COST. DRAWN MARK MONTALTO JR DATE 04/1312020 SCALE AS NOTED SHEET NO. 03 OF 10 SHEETS ti M �4 41-211 I I FOOTING F•9 I 27'-4" 1Aoll 4' 41411 4'-6" REF. 5&4' 2Il_011. F� FTG 1 = 3 0'-0 TOP OF SLAB WABHER LOCAno 4"THICK (2500 PSI) CONCRETE SLAB w/ FIBERMESH OR S"/ 6" 10/10 W WM OVER VAPOR BARRIER ON CLEAN 151-V _� COMPACTED CHEMICALLY TREATED FILL FOOTING F-9 41A11 41-211 ' 19.11 �`I I III II „ II _ rt ^LL L TUB/SHOWER 3'-1011 I 4'-6- J O.m N' 8'-0' 20'-8' 4'-lw 64P 41-01, FOOTING F-9 w z cr w W cc J O w LU w / HU c f p r P ECTION P03T LL�li ' z 8� NQ m 7 c .,s folmm WE NW 3-1/2' STEP 0 C w l .< wo O W '----------------�`'—F'-- 0 N I 10 /' I a I 8 X 16" FTG BLK COLUMN 1 11.6" 16'4" 30'-4" 6'-0. 191-8.1 56'-0" SCALE: ABC CHASE � � t BVPwMBER �. \ y FPLMETER f UTILITY PAD U 1 Z FTG AICCOND LLUL IL v IL L O' 0 a U � N 3 RECESS SLAB 3-VT I,' �. ._ O BELOW FINISH FLOOR W ___ ) !• w! FIBERMEBH-BI'7�6' 10/'10 W WM I I �Q w OVERNAPORBMRIERON CLEAN I I. a COMPACTED CHEMICALLYTREATED FILL , I I CURB HEIGHT w1F0E5 AROUND PERIMETER F RAGE � F-1 FTG A I I I•• m ' L O m I I'' m LU #5 REBAR FINISH FLOOR CONCRETE SLAB O 411 CONCRETE SLAB - F. FLOOR - FINISH GRADE - - CV r /° co .r (2) # 5 REBAR 12" 16° 4" (2) # 5 MINIMUM CONTINUOUS, CONTINUOUS �( 3" COVER MIMIMUM. 1 F2 BEARING FOOTING INTERIOR NON-BRG. FTG. FSCALE: 1/2" = 1'-0" SCALE: 1/21'= 1'-0" n�#5 REBAR Z_ II 75/8" CURB � z u 0 #5 REBAR CONCRETE SLAB FINISH GRADE 4„ °. M L j CONCRETE SLAB - — - Z V411 CONCRETE SLAB R OOR M CONTINUOUS, ,)s„R MIMIMUM. (2) # 5 MINIMUM CONTINUOUS, 1 �° 4' 3" COVER MIMIMUM. F3 CURB' SECTION EXTERIOR STEP SCALE: 1/2" = 1'-0" SSCALE: 1/2" - 1'-0" # 5 REBAR WITH 30" MIN. LAP SPLICE # 5 VERT. REBAR IN (3000 PSI) CONCRETE FILLED CELL. (SEE FOUNDATION PLAN FOR LOCATIONS) # 5 CONTINUOUS 4" THICK CONC. SLAB STUCCO FINISH w/ W X W I0/10 W.W.F. V X V FHABLOCK WITH (1) # 5 BAR CONTINUOUS W a V X V X 16" CONCRETE BLOCK (MASONRY) a > ALL CELLS FILLED WITH (3000 PSI) CONCRETE FINISH GRADE fV .- (2500 PSI) CONCRETE SPREAD FOOTING (2) # 5 BARS CONTINUOUS 16" TYPICAL STEM WALL FOOTING DETAIL SCALE: 1/2" = V-0" BEND # 5 BAR INTO SLAB # 5 REBAR WITH 30" MIN. LAP SPLICE # 5 VERT REBAR IN (3000 PSI) CONCRETE FILLED CELL. (SEE FOUNDATION PLAN FOR LOCATIONS) 8" X 8" FHA BLOCK WITH (1) # 5 BAR CONTINUOUS STUCCO FINISH W X W X IV CONCRETE BLOCK (MASONRY) ALL CELLS FILLED WITH (3000 PSI) CONCRETE FINISH GRADE (-SEE ELEVATION PLAN-) (2500 PSI) CONCRETE SPREAD FOOTING (2) # 5 BARS CONTINUOUS C'` TYPICAL STEM WALL FOOTING DETAIL SCALE: 1/2" = V-0" REVISION REVISION z i CO F Lu K O W = IL ��. .: rrxd. •i {A OF V ENGINEER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 vJ N W 0) Z Lu Ch U 0 Q � c0 QW� U W m .0 °) U) X rt � � W IL LCL Lo W co O W LI- LLJ O0 J p W LL O a U Lj J J w e V 0 r SHEET .F UNDATION PAGE MODEL ARUBA CUST. DRAWN MARK MONTALTO JR DATE 04/30/2020 SCALE AS NOTED j SHEET NO. 05 OF 10 SHEETS Job #: Performed for: 594 Beach Ave (Wilson Res) 2401 sw Monterey Lane Port St Lucie, FI 34983 Sheet 1 Air Conditioning Unlimited LLC 5565 Burgin St Port St Lucie, FI Scale: 1 : 93 Page 1 RightSuite® Universal 2019 19.0.08 RSU06570 2020-Apr-26 10:12:20 ...tsoft HVAC\594 Beach Ave-PSL. ^19 REVISION REVISION O = Y GO t~i W w Y C1 = IL 0 „pn mOnhlrrr ENO 0 '. T�8 3T :� E OF =moo T �0RID.P.•= t� FSS EN61NEEl BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 U5 C4 W rn Z W M V 0 O taco QWw� U Lij m_jO °)(f)X 0 LO�W CE 2„ M In O) WC 3 W M TUB 3" �— p O 4„ W LL LL 3" N®�/ LL H �' H 4„ W 4" U IL LLI PLUMBING RISER < NO SCALE J uJ of � vJ w Z PLUMBING NOTES: 1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2017-PLUMBING 2) DWV PIPING SHALL BE SCHEDULE 40 PVC. RM 3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BLDG. 5) HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN %n NOMINAL DIAMETER, PIPING FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, BURRIED PIPING, SUPPLYAND RETUN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. IFILE. CO 6) WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2017 ENERGY CONSERVATION. O U) C o N SHEET HVAC PAGE MODEL ARUBA CUST. DRAWN MARK MONTALTO JR DATE 04/30/2020 SCALE AS NOTED SHEET NO. 07 OF 10 SHEETS N z° xwaxer'.'Y g �:-w;l.W.,_r,.t� x.. , a.m., ..<, _ M�s'•tcw... k YREVISFVn a r Fi sy j i { 56' 0" k 27' 4" 8' 0" 20' 8" U D w U CA o CA i M aNO SRG G2 N 2' 0„ 2' 0„ 2' 0„ 2' 0„ 2' 0„ TO o j Er 3 '^ CV M N W W a D D D D D a N m a m g N M E v, o 0 0 0 ti�� c3 0 W m m W a g G1 a a a a o o 0 0 �� Lo Lo Hatch Legend cJ1 10' 10' 0" o 03 0 1211 1/4 o cJ1 Z uj 0 a iv 5' 1 / LL �O`^ ��co CJ o ¢ CJ3 V J J U LLI Ll.j Qom CJ q CJ5 Q W J fn TRUSS END DETAIL Fz EJ7EJ7 L W m /�, le 3/ V T �i)X EJ7VLNII - EJ7 PLUMB CUT OVERHANG B O Lo '. TO„ 2' 0„ 0„ " 2' 0„ 2' 0„ 2' 2' „ 0„ 2' 0„ 2' „ , 0„ 2' /0, 0„ N W N NN N N a. O OEJ7c EJ7 a.ans• ' u -1" —1 HEEL HEIGHT n V-1" CLNGx c I IS N /► N EJ7o EJ7 b N N 8'-1" CLNG N f° EJ7 t key" EJ7 1 1 2 EJ7 ER ATTI VO o zo ''• AHU EJ7 M C ♦ ^ Lo N N EJ PLAT ORM W m N3/1 A T NVO6 EJ7 Q CJ V () 3 TT EJ7 ? CJ N9 /4' Voa ATTIC 10,1011 64 ST GE NilW LL 4NI IN C,11 j j j x x x= 2 PLY EJ7 157 W BRCS O U rnj X D D02 LS U CJ3 w " J o m > > 8'-1" CLNG L,rDT BRGc CJ1 � D02 � it , 2ND BRG O D02 a Uw D03 ILLj Z � � J D04 J Lu 30' 4" 6' 0" 19, 8" Z 56' 0" k OC e o �_ C) NOTE: � O VALLEY TRUSSES MAYBEATTACHED WITH SIMPSON VTCR w/ (4) # 9SD X 2-1/2" TO SUPPORTING TRUSSAND (3) # 9 SD X 1-1/2" TO VALLEY TRUSS IN LIEU OF MTS16 AS g FOR MISSED TRUSS CONNECTORS AT STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX. BLOCK WALLS WITH 1175 #UPLIFT OR LESS, PROVIDE "SIMPSON" HTSM WITH (4) 1/4" X 1-3/4" TITEN, AND (10) 10d. SHEET TRUSS LAYOUT PAGE ' f1 FOR MISSED TRUSS CONNECTORS MODEL ARUBACUST. FOR TRUSSES WITH ENGINEER # UPLIFT USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN. EMBEDMENT FORANCHOR BOLTS (A.B.) DRAWN OR MORE, CONSULT ENGINEER FOR MARK MONTALTO JR ADDITIONAL TRUSS CONNECTOR OPTIONS DATE 04/30/2020 SCALE AS NOTED SHEET NO. 08 OF 10 SHEETS TRUSS CONNECTOR SCHEDULE TRUSS NOTES: 9)ALLROOFTRUSSESTOBEDESIGNEDBYTRUSSCOMPANY'SENGINEER. 2) CONTRACTOR TO PROVIDE ENGINEER ,AND BUILDING DEPARTMENT WITY-1 ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 4) CONTRACTOR TO VERIFYALL IXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 5) SEE TRUSS CONNECTOR SCHEDULE FOR TRUSS TO WALL CONNECTIONS CONTRACTOR: PSL PROPERTIES OWNER: WILSON RESIDENCE TRUSS BUILDERS FIRST SOURCE LAYOUT DATE: oa / 29 / 2020 CUT -SHEET DATE: 04 / 29 / 2020 TRUSS Id BEARING POINT TRUSS ACTUAL UPLIFT CONNECTOR ID CONNECTOR UPLIFT DESIGN FASTENERS NOTES 804 1ST, 2ND 962 (1) HETA20 1310 (9) 10d X 1-1/2" D01 1ST 2ND 619 (1) HETA20 1810 (S)16d Doa CONT. 257 # PLF 1810 (14) 10d X 1-1/2" SEE GABLE END DETAIL 1 STRAPAT EACH END AND 48" O. C. T„ VALLEYS CONT 100 # PLF O MTS 18 1000 (9) 10d X 1-1/2" 1 STRAPAT EACH END AND 24" O. C. �� ALL OTHERS Arces BEARING EACH <1800 # (1) HETA20 1810 (9) 10d X 1-1/2" 4� AT CBS BEARING k' f' 1 o = m 0 Y i U 0 z Z W (- O it O O 0 F, 1/16" X 3" TAPCONS @ 12" O.C. (TYPICAL) •1/2" REDHEADS w/ 2" DIA. X 1/8" WASHER AL) PT) OR 2" X 8" (PT) BUCK (TYPICAL) E FINISH FLOOR GARAGE DOOR JAMB ATTACHMENT TO CBS WALL (16-0' X 8'-0" & T-O" X 8'-0" GARAGE DOORS) 1. JAMBS: 2" X 6" OR 2" X 8" P.T. w/ 3/8" X 5-1/2" EMBED. TITEN HD w/ MIN. 2" DIA. X 1/8" WASHER. (TYPICAL) 2. HEAD: 2" X 6" OR 2" X 8" P.T. w/ 3/16" X 3" TAPCONS AT 12" O.C. 3. TORSION SPRING BLOCKING 2" X 6" P.T. w/ (4) 3/16" X 3" TAPCONS w/ 5/8" WASHERS. (STAGGER GRAIN) M AT 1"10111 AI I/ Ll TRUSS BOTTOM CHORD 1/2" DRYWALL CEILING 2" X 4" TOP PLATE OR 1-1/2" X 3-5/8" METAL RUNNER 2" X 4" WOOD FRAMING @ 24" O.C. OR 1-1/2" X 3-5/8" METAL STUDS NO SCALE 1/2" DRYWALL BOTH SIDES (TYPICAL ALL WALLS INCLUDING GARAGE) 2" X 4" BOTTOM PLAT OR 1-1/2" X 3-5/8" METAL RUNNER w/ TAPCONS OR CUT NAILS @ 2'-0" O.C. (10d NAILS FOR WOOD FLOOR) EXISTING FLOOR TYPICAL INTERIOR NON -BEARING WALL DETAIL NO SCALE a W J EAVE O u RIDGE,\ �T G tom. 9l O EAVE (TYPICAL GENERIC ROOF PLAN "PLAN VIEW) A = 5 FEET ROOF SHEATHING ATTACHMENT REQUIREMENTS ZONE 1Q NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD ZONE 0 NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD NOTE ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE. ROOF SHEATHING NAILING ZONE (3) 16d NAILS (TYPICAL) CEILING PER 2"X4" SPRUCE OR BETTER LATERAL BRACE @ 6' O.C. FASTENED TO TOP OF BOTTOM CHORD OF TRUSSES WITH (2) 16d NAILS EACH, AT GABLE END TRUSS AND 4 TRUSS BACK P.T. 2" X 8" CONTINUOUS WITH 1/2" " J " BOLT OR 1/2" X 5-1/2" WEDGE ANCHOR AT 24" O.C. WITH 2" X 2" X 1/8" WASHERS GABLE END DETAIL NO SCALE 19/32" ROOF SHEATHING ROOFING UNDERLAYMENT PER PLAN 2"X4" "X" BRACING @ RIDGE AND 6' O.C. EACH SIDE OF RIDGE 2"X WOOD FASCIA w/ALUM. DRIP EDGE SOFFIT (SEE DETAIL) 2" X 4" LADDER FRAMING @ 12" O.C. 1/2" STUCCO EXPANSION JOINT STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" DIAMETER HEAD @ 6" O.C. OVER (2) LAYERS OF (15 # FELT OR TYVAK BUILDING WRAP) OVER 15/32" CDX PLYWOOD WITH 10d NAILS TO STUDS @ 6" O.C. PERIMETERAND FIELD. GABLE END TRUSS 16d COMMON NAILS @ 12" O.C. STRAP GABLE END TRUSS WITH "SIMPSON" HETA 20 AT 48" O.C. WITH (9) 10d X 1-1/2" NAILS EMBED STRAP IN BEAM 4" NOTE: PROVIDE RAKE BEAM @ VAULTED GABLE ENDS TRUSS VERTICAL WEB REINFORCE EACH VERTICAL MEMBER OF GABLE END TRUSS WITH 2" X 4" T-BRACE WITH 16d NAILS AT 8 INCHES O.C. 12 6 PRE-ENGINEERED WOOD TRUSSES 2XPT BLOCKING @ COLUMN SIMPSON STRAP PER SCH. 9'-4" FROM FINISHED FLOOR , SOFFIT PER DETAIL EXTERIOR CEILING TO BE 8" BEAM BLOCK STUCCO OVER WIRELATH W/ (1) # 5 BAR IN 3000 PSI w/ 11GA. 2" NAILS w/ 3/8" DIA. CONCRETE FILLED CELL. HEAD @ 6" O.C. OVER 8" PRECAST LINTELS 3/8" METAL RIB LATH @ 6" W/ (1) # 5 BAR FOR O.C. w/ (2 LAYERS OF 15 # OPENINGS & FILLED FELT OVER EACH W/ 3000 PSI CONCRETE FRAMING MEMBER) 8" X 16" CMU COLUMN W/ (2) # 5 BARS VERT. w/ STUCCO FINISH (3000 PSI) CONC. FILLED CELLS. STUCCO FINISH (2) # 5 DOWEL w/ 3011 or MIN. LAP SPLICE VERTICAL DOWELS FROM FOOTER R_�IE CODE COMOLL, T, LUCIE COS,' FOOTING PER PLAN ENTRY & PORCH COLUMN DETAIL NO SCALE NOTE: SEE TYPICAL WALL SECTION FOR MORE INFORMATION FILE C . REVISION REVISION z z s m t~t w a" d = .7 (E� ST OF '-"S 0.616MER BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70878 i U5 LN W (3) z Luc U O O dLLW W�w Q U m J U) ® Ln X a � W M Ln W 14, Ch `W 1 0 0 W J LL W ® U J H W 0 LU � � Q J J W r� VJ W Z O U) ^ o N SHEET DETAILS PAGE MODEL ARUBA CUST. DRAWN MARK MONTALTO JR DATE 04/30/2020 SCALE AS NOTED SHEET NO. 09 OF 10 SHEETS CMU Wi (SEE WF CORROE PER V APPLY PE BETWEE (SEE V1 FILLED CELLAT JAMB BLOCK (TYPICAL) 1" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS. SEE WATER PROOFING NOTE # 6 ANCHOR 1"X 4" P.T. (MIN.) BUCK WITH SEALANT PER WATERPROOFING NOTE # 4, AND ANCHORED TO MASONRY WITH 1-112" CASE HARDENED COIL NAILS AT 12" O.C. MAX. ANCHOR WINDOW FRAME TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCTAPPROVAL INSTALLATION REQUIREMENTS. D JAMBS TYPICAL BUCK DI NOTE: TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/ MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. NOTE: WINDOW AND DOOR FENESTRATIONS IN ACCORDANCE WITH FBC R703.4 (1.2) AS PER DETAILS PROVIDED 3/4" NOTE: PRECAST CONCRETE WIND RESISTANT FLUSH /$" SILL AS MANUFACTURED BY CAST-CRETE (OR EQUAL) 1-3/8" PRECAST CONCRETE WINDOW SILL DETAIL NO SCALE STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 2 FILLED CELLAT JAMB BLOCK (TYPICAL) 1" X 3" P.T. WOOD FURRING ALL (3) SIDES CONTINUOUS WOOD TRIM 1" X R T WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE # 4 AND ANCHORED TO MASONRY WITH 1-1/2" CASE HARDENED COIL NAILS (d 12" O.C. MAX SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB AND HEADER TO 1 x BUCKS IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE # 4 APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE # 5) EXTERIOR D BUCK D NOTE: TAPCONS TO BE INSTALLED THRU BUCK INTO MASONRY w/ MIN. 1-1/4" EMBEDMENT PER PRODUCTAPPROVAL PER FBC 1715.5.4.3. BUCKS MUST COVER ENTIRE DEPTH OF JAMBS. CONTINUOUS FOAM INTERIOR AIR AND WATER SEALANT PER WATERPROOFING NOTE # 6 MARBLE SILL MORTAR OR GROUT 1/2" DRYWALL FILLED CELL AT JAMB BLOCK (TYPICAL) 1" X 3" P.T. WOOD FURRINGALL (3) SIDES CONTINUOUS c WOOD TRIM P: 2" X P. T WOOD BUCK WITH SEALANT PER WATERPROOFING NOTE # 4 AND ANCHORED TO MASONRY WITH 1/4" TAPCONS w/ MIN. 1-1/4" EMBED. 3" FROM EDGES & 12" O.C. MAX. SEE WATER PROOFING NOTE # 6 ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCTAPPROVAL INSTALLATION REQUIREMENTS. NOTE: BUCK 2"X 6" P.T. RIPPED DOWN TO 2 X 4-1/8" P. T. w/ 3/16" TAPCONS 1-1/4"MIN. EMB. 4112" O.C. w/# 10 SCREWS, PER PRODUCTAPPROVAL. FASTENERS AS REQUIRED BY WINDOW MANUFACTURER CORROSION RESISTANT FLASHING PER WATERPROOFING (NOTE # 2) CAULK SEAM AT WINDOW INSTALLTION (SEE WATERPROOFING NOTE # 5) CMU WATER RESISTANT COATING (SEE WATER PROOFING NOTE # 1 ) SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C.M.U. 3/4" FURRING TO MASONRY WALL WATERPROOFING NOTES: l . PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURE'S RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESISTANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECTION. ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. FBC R703.4AAAMA-714 2. INSTALL BUCKS SO THAT THEREARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCKAND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. 4. PROVIDE PAN FLASHING AT THE SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILLAS WELL. PAN FLASHING SHALL BE CORROSION RESISTANT. (OPTIONAL, NOT REQUIRED) 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES ATALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR INSTALLATION. 6. AFTER WINDOW / DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIORAIR SEALAROUND THE ENTIRE PERIMETER. REVIF-IFI) CODE C AV" ST. LUCIE C SOC( FILE CUB REVISION REVISION O = Y fa w W Y U LL = Cf '. S ATE OF ,,y .,fi gyp•.•• r. unuun� BENCHMARK ENGINEERING BOWDOIN G. HUTCHINSON, P.E. REG. # 70B78 (n N W Ln z WM� O U Q LL Qww� U W °� J O m�a. 0� a- tl I, ^W CL O rW V D M LE) m M Q 0 O J LL LL U D J IL LJJ Q J Lu of Z O U) O N SHEET DETAILS PAGE MODEL ARUBA CUST. DRAWN MARK MONTALTO JR DATE 04/30/2020 SCALE AS NOTED SHEET NO. 10 OF 10 SHEETS