Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method { Project Name: 594 Beach Ave Builder Name: Port St Lucie Properties Street: 594 Beach Ave Permit Office: St Lucie County City, State, Zip: Port St Lucie , FL , 34952 Permit Number: Owner: Wilson Res Jurisdiction: 611000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1329.0 sgft) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 10B320 R2 b. Frame - Steel, Adjacent R=11.0 158.97 fie 3. Number of units, if multiple family 1 c. Frame - Steel, Exterior R=11.0 86.96 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1351.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1211.00 fF 6. Conditioned floor area above grade (ft2) 1211 b. Knee Wall (Vented) R=30,0 80.00 fe c. N/A R= 1`12 Conditioned floor area below, grade (ft2.) 0 11. Ducts R ft2 7. Windows(154.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 2542 a. U-Factor: SgI, U=0.58 114:67 ft SHGC: SHGC=0.24 b., U Factor: Sg1, U=0.68 40.00 ft2 12. Cooling systems kBhOr Efficiency SHGC: SHGC=022 a. Central Unit24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A fe a. Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.293 R Area Weighted Average SHGC: 0.235 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1271.0 sgft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1271.00 f12 b. Conservation features b. NIA R= f12 None c. WA R= ft2 15. Credits Pstat Total Proposed Modified Loads: 46.99 0.122 c SS PASS Glass/Floor Area: Total Baseline Loads: 47.68 I hereby certify that the plans and specifications covered by Review of the plans and Q�-VIIE S7,4 this calculation are in compliance with the Florida Energy specifications covered by this 4V ; t= O,r, Code. calculation indicates compliance with the. Florida Energy Code. =,.' err:,, '-°�,*='', PREPARED BY: A/40'/ DATE: A0111is Before construction is completed this building will be inspected for compliance with Section 553.908 a I hereby certify that this building, a esi d, is in Aplian Florida Statutes. �c�D With the Florida Energy Code. WE OWNER/AGE T� BUILDING OFFICIAL: DATE: ZZ Z DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an',Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an ,envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 4/2512020 2:52 PM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 cnone QAnr._)n17 IAIPI IT Q1 IMMARV rt4F(_Kl 1ST RFPf)RT PROJECT Title: Building Type: Owner Name: # of Units. Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment 594 Beach Ave User Wilson Res 1 Port St Lucie Properties St Lucie County 611000 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1271 Total Stories: 1 Worst Case: No Rotate Angie: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street:. 594 Beach Ave County: St. Lucie City, State, Zip: Port St Lucie , FL, 34952 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number. Name' Area Volume 1 13lockl 1271 11095.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1271 11095.8 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Stab -On -Grade Edge Insulatio Main 164 ft 0 1271 ft' — 0 0 1 ROOF # Roof Gable Roof Type Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1421 ft' 0 ft= Light N 0.96 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1271 ft' N N CEILING # Ceiling Type Space R-Value Ins Type, Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wag (Vented) I Main 30 Blown Main 30 Blown 1271 It' 0.11 Wood 80 ft' 0.11 Wood 412512020 2:52 PM EnergyGauge@ USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 2 of 4 i r-r%MRR oAnrz 7n47 IAIDI IT CI IMMADV r1411=11KI ICT RFPnRT i WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below �rr�t Tip WaIl Tvpe Space R ValpP Ft In Ft In Area R-Valnp Fractinn Ahgpr rra ° _ 1 N Exterior Concrete Block - Int Insul Main 4.09999 36 4 8 1 293.7 ft' 0 0.600000 0 2 N Garage Frame - Steel Main 11 19 8 8 1 159.0 ft' 0.23 0.600000 0 _ 3 W Exterior Frame - Steel Main 11 10 9 8 1 86.9 ft2 023 0.600000 0 _ 4 W Exterior Concrete Block - Int Insul Main 4.09999 15 1 8 1 121.9 fP 0 0.600000 0 _ 5 S Exterior ;Concrete Block - Int Insul Main 4.09999 48 8 1 388.0 f12 0 0.600000 0 _ 6 S Exterior ;Concrete Block - Int Insul Main 4.09999 8 8 1 64.7 f 2 0 0.600000 0 7 E Exterior Concrete Block - Int Insul Main 4.09999 26 7 8 1 214.9 ft' 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Area Ft In I Ft In n 1 N Insulated Main None .21 3 6 8 20 ft' 2 W Insulated Main None .21 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.58 0.24 Y 48.6 ft' 1 ft 0 in 1 ft 0 in None None 2 W 4 Metal Low-E Single Yes 0.58 0.24 Y 4.7 f 2 1 ft 0 in 1 ft 0 in None None 3 S 5 Metal Low-E Single Yes 0.58 0.24 Y 48.6 fi' 1 ft 0 in 1 ft 0 In None None 4 S 5 Metal Low-E Single Yes 0.58 0.24 Y 12.8 ft' 1 ft 01n 1 ft 0 in None None 5 S 6 Metal Low-E Single Yes 0.68 0.22 Y 40.0 ft' 6 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 401.94 ft' 401.94 ft' 50 ft 8.1 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000277 924.7 50.76 95.47 .0995 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Single HSPF:9 24 katuThr 1 sys#1 4/25/2020 2:52 PM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 1W nInI rr rI IannewoV t-uCf%ill ICT DCDP11?T COOLING SYSTEM # System Type, Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit . None Single SEER:16 24 kBUhr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None fF DUCTS - Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 254.2 ft Attic 63.55 ft Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y ' Ceiling Fans: Coolingt Jan [j] Feb Heatin[X] Jan [XI Feb Mar Mar [ r [ ]r May Jun n Jul May Jun Jul AugX] Au[ rl Se ]Sep [ Oct [ ]Oct W Nov Nov HX Dec Dec Ventin [[[[ IIII Jan III 111 Feb X Mar [XJ r [ Ma JJJ Jun Jul l Aug I 1 Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3_ 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 so 78 78 80 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 7.8 78 Heafing(WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating(WEH) AM PM 66 68 66 66 68 68 66 66 68 .68 68 68 68 68 68 68. 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Defau 8 Ibs/s .ft. 0 fN 0 ft 0.3 Main 4/25/2020 2:52 PM EnergyGauge® USA 6.0.02 (Rev. 1) 7 FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The, lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor,area (sq. ft.) 6. 1271 7. Windows, type and area a) U-factor(weighted average) 7a.. 0.606 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.235 c) Area 7c. 154.7 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on - .grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 90. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 10A1. 11.0 2. Masonry (Insulation R-value) 10A2. .4.1 B. Adjacent: 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 11. Ceiling type and insulation level a) Under attic ' 11 a. 30.0 b) Single assembly 11b. c) Knee walls/skylight walls' 11c. 30.0 d) Radiant barrier installed 11d. No 13. Cooling system: Capacity24.0 a) Split system SEER b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 16.0 14. Heating system: Capacity 24.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 9.00 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EFL_ d) Solar system with tank EF e) Dedicated heat pump with tank EF. f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will becompleted bas ins Iled code mpliant features. Builder Signature: Date:? 7 Zo Zd i Address of New Home: 594 Beach Ave City/FL Zip: Port St Lucie, FL 34952 4R5R020 2:52,47 PM I EnergyGaugeO USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edt ion (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation; 6th Edition Jurisdiction: :61.1000 Permit 0 Builder. Port St Lucie Properties Community: Lot: NA Address: 594 Bead? Ave City- Port St Lucie State: FL Zip: 34952 Air Leakage TeResults -passing, results must meet either the Performance,manPerformance,Pms orERIVethod pt, 0 PRESCRIPWE Ii qHOD-The buldifig ordwelfipg'uriltoall be tested and verified as having an air leakage rate of not exceeding 7 air changesper hdur of 0.2 inch w.9. (50 Pascals) In Climate Zones 1 an&�' at a pressure PERFORMANCE or ERI IY!EtHOD�Jhe building or dwqlrmb unit shelbetest6d and verified as having an air leakage rateof not exceeding the selected ACH(56)i valde,as sfioWn on Form R405-2017'(Oerf6rmance) or-R4W?017 (EFO), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Cale (Perfurrience) or R40&201 7 (ERI): 5.000 Method for calculating building x 60 11096 _q volume: CFM(50) Building Volume, ACH(50) 0 Retrieved from architectural plans F-1 PASS 0 Code software calculated ElWhen ACH(5b) is less than 3, mechanical Ventilation installation (D Field measured and 'calculated must be verified by building department. - L _j R402.4.12 Testing. Tesfihg shall be conducted In accordance with ANSURESNET111310, 380 andreportedat a pressure of 02 Inch w.g. (50 PaSWIS). Testing shall be conducted by either Individuals as defined In Section 553.993(5) or (7), Florida Statues.or Individuals licensed asset forth in Section 489.105(3)(0, (g), or (Q or;an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode offici& Testing shall be performed at any time after creation of all perii6trations of the building thehnal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the intended weatherstripping or other Infiltration control measures' 2. Dampers Including exhaust, Intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond Intended Infilttatioriicontrol measures. 3. Interior doors, 9 Installed at the time of the test shall be open. 4. Exterior doors for continuous ventilation systems and, heat recovery ventilators shall be closed and sealed. ' 5. Heating and cooling syitems, if Installed at the time of the test, shall be turned off. 6. Supply and retuim registers, if installed tit the time of the test, shall, be fully open. Testing Company Company Name: Phone: I hereby verify that thb above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation, requirements according to the compliance method selected above. Signature of Testet. Date of Test: -Printed Name of TeSter. Licehse/CertificAtion Issuing Authority: 4r2512020 2:52:59 PM EnergyGaug6O USA 6.0.04 _(Rev. 1) FlaRes2017 FBG 6th Edition (2017) Compliant Software, Page 1 of 1 Job #: Performed for: 594 Beach Ave (Wilson Res) 2401 sw Monterey Lane Port St Lucie, FI 34983 Sheet 1 Air Conditioning Unlimited LLC Scale: 1 : 93 Page 1 5565 Burgin St Right-Suite®Universal 2019 Port St Lucie, FI 19.0.08 RSU06570 2020-Apr-26 10:12:20 ...tsoft HVAC\594 Beach Ave-PSL.r.