HomeMy WebLinkAboutproduct approval (4)2/1/2019 Florida Building Code Online _
O• 0. 05RARTM5W OF
Professional Regulativt1l
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge ( Stats & Facts I Publlcatlons I Contact Us I BCIS Site Map I Links I Search I
Florida •
} Product Approval
USER: Public User
,Product Approval Menu > Product or Application Search > > Application Detail
FL # FL5374-R5
Application type Affirmation
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
East Coast Metals, Inc.
2301 West 8 Lane
Hialeah, FL 33010
(305) 885-9991
acastellanos@eastcoast-metals.com
Tom Castellanos
acastellanos@eastcoast-metals.com
Tom Castellanos
2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
tcastallanos@eastcoast-metals.com
Howard Callender Jr.
2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
hcallender@eastcoast-metais.com
Roofing
Roofing Accessories that are an integral Part of the Roofing System
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nleminen
PE-59166
Architectural Testing, Inc., an Intertek Company
12/31/2020
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Fi 5374 R5 COI 2015 01 COI Nieminen.pdf
Standa
Year
FRSA/rRI April 2012 (04-12)
2012
RAS 118
1995
RAS 119
1995
RAS 120
1995
SBCCI SSTD 11
1997
TAS 101
1995
https://www.floridabuilding.org/pr/pr app dti.aspx?param=wGEVXCIwtDgtVSv8n7ODFXfTAZV6GMEbU0PIe6Y8w7vk%3d 1/2
2/1/2019
Equivalence of Product Standards
Certified By
Sections from the Code
Florida Building Code Online
,;'. I affirm that there are no changes in the new Florida Building
Code which affect my praduct(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes !No = N/A
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FL5374 R5 COC 2017 09 AFFIRMATION ECM FL5374 6th Edition
.(2uz)- Pff
Method 1 Option D
09/06/2017
09/06/2017
09/10/2017
FL #
Model, Number or Name
Description
5374.1
East Coast Metals Channel Metals
Preformed metal channels designed for use as a hip & ridge
base to which roof tiles are bonded.
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
F S374 RS II 2015 03 FINAL ER ECM Trim Lock FL5374-
R4.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-178
Created by Independent Third Party: Yes
Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 for
Evaluation Reports
Umits of Use in HVHZ and non-HVHZ jurisdictions, respectively.
FL5374 R5 AE 2015 03 FINAL ER ECM Trim Lock FL5374-
g4.pdf
2.) The design pressure herein pertains to use in non-HVHZ
jurisdictions in conjunction with Table 1A of FRSA/TRI April
Created by Independent Third Party: Yes
2012 (04-12). Refer to Tables 2A and 2B in the Evaluation
Report for all options and associated allowable design
pressures.
Badc waxt
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone, 850-487-1824
The state of Florida is an AA/EEO employer. 9MYAght ZOD7-2o13 State of Egdda, :: PrivapZ Statement :: Accessibiljty Statement :: Refund Statement,
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public-racords request, do not send electronic
mall to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact $50.487.1395. *Pursuant to Section 455.275(2),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address Ifthey have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, RS., please dick e e .
Product Approval Accepts;
®®®0®
Credit Card
Safe.
httpsJJwwwfloridabuilding.org/prlpi app d8.aspx?param=wGEVXQwtDgtVSv8n7ODFXfrAzV6GMEbUOplaBY8w7vk%3d 2/2
TRINITY i ERD
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certjf%ate of Authorkation #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
East Coast Metals, Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-R4
Hialeah, FL 33010 Date of Issuance: 09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the Sur Edition (2014) Florida Building Code sections. noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED CoMPuANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD.requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityjERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Thefacsimle seal appearing was authorized by Robert Nieminen,
P.E. on o3/17/2015: This does notserveas an electronically signed
document. Signed,sealed hardwpleshavebeentransmittedtothe
ProdurtApprovalAdministrator andtothe named dient
CERTIFICATION OF INDEPENDENCE:
1. TriniitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
f
F"'K D '/
`,- a TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category. Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the installation Requirements and limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118,119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD (TST6049)
Static Uplift Resistance
ECM SC6795.12.14-1
02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM SC6795.12.14.2
02/27/2015
Florida TEC (TST7393)
TAS 101
S1O.628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/1.312008
PRI (TST5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-006.02-01
06/13/2009
PRI (TST5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI (1`ST5878)
TAS 101
ECM-008-02-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/TRI April 2012 (04-12)
04/2012
Florida Building Code - HVHZ
Attachment Requirements
RAS 118,119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing (QUAILS")
Quality Control
Participation Letter
Exp.12/31/2038
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch L
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch)
heights with 1.54nch (} 1/16-inch) deck -flanges.
Exterior Research and Design,llC. Evaluation Report E10240.08.08-R4
F13
CerNJicareofAutboAsadon #9503
Revision a: 03/17/20157/2035
Page 2 of 7
t•
�-,J
TRINITY t ERD
{
4.2 Trim Lock Channel Metal: Pre formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal Is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying file adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (+
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch L 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying the adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(± 3/81 length by 3, 3.5, 4, 5 or 6-inch (+ 3/8-inch) heights
with 1.5-inch L 1/16-inch) deck -flanges.
4,4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019 + 0.002-inch, ASTM A653 (6-90), min. 33 KSI.
➢ Galvalume Steel: Min. 0.019+0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032 ± O.Ob2-inch, ASTM B209, 3003-1-114, min.21 KSI.
➢ Stainless Steel: Min. 0.019 ± 0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
CerWcne ofAuthafaahm M03 Revision 403/17/2015 PL: 7/?A15
Page 3 of 7
r �'1111 TRINITY I ERD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Pius are limited to projects having a required moment resistance (Mr) or uplift resistance (Fr),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the file adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual Ile is bonded to the Channel Metal in its own, single
foam paddy; the head laps are not bonded. This method is limited to 2-part the adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
„, Z'J111D'EPE111�E AD
:...: .. :... �. P
TAiilfsD�RA�AEi:111i�
l. RMAP2CE•LIMITAfIONS_ - , M A,,,
_
.:r
1 •-.1•Y,
f" - .A .
IIrA�3AF.E7i' LREAO �IiP. f
HI Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
MetaIType
Type
Placement
Mr(ft Ibf)
F' (ibf)
Hip & Ridge
clay or
3MTM 2-Component Foam
Independent
127
169
Channel Metal
galvanized
concrete
Roof Tile Adhesive AH-160
galvanized, Galvalume®,
clay or
3MTM 2-Component Foam
Independent
271
159
Trim Lock
aluminum or stainless steel
I concrete
Roof Tile Adhesive AH-160
galvanized, Galvalumem,
I clay or
3MTM 2-Component Foam
independent
177
165
Trim Lock Plus
aluminum or stainless Me{
I concrete
Roof Tile AdhesiveAH-160
- �°INTERUEPENDEIIIT' `DY.Pi:ACEAhEgIF.,-
,.:. •ti: • Gf"ATiQNS`.:HV�i`t'. ....:
•B. PER�.:,:�tMAN �
t'ED
4''it3 AIWRGW.
.:SA(PI:Y
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplfft Based
Design
Metal Type
Type
Placement
Mf ('ft-Ibf)
V (Ibf)
Trim Lack or Trim
galvanized, Galvalume®,
clay or
3MTM 2-Component Foam
interdependent
95
88
Lock Plus
aluminum or stainless steel
concrete
Roof Tile AdhesiveAH-160
galvanized,Gaivalume®,
clay or
31VITM Roof Tile Adhesive
interdependent
99
94
Trim Lock
stainless steel
concrete
RTA 1
clay or
3MTM Foam Roof Tile
interdependent
90
84
Trim Lock
aluminum
concrete
Adhesive RTA-1
Saivanlzed, Galvalume•,
clay or
3MTM Foam Roof Tile
interdependent
90
84
Trim Lock Pius
aluminum orstainless steel
concrete
Adhesive RTA-1
galvanized, Gaivalume• or
day or
TiLE BONDTM Roof Tile
interdependent
123
117
Trim Lock
stainless steel
concrete
Adhesive
clay or
TILE BONDTM Roof Tile
Interdependent
79
73
Trim Lode
aluminum
concrete
Adhesive
galvanized, Galvalume®,
day or
TILE BOND- Roof Tile
Interdependent
79
73
Trim Lock Plus
aluminum or stainless steel
concrete
Adhesive
galvanized, Galvalumem or
clay or
Touch 'nSeal StormBond
Interdependent
246
139
Trim lodt
stainless steel
concrete
Roof Tile Adhesive
clay or
Touch 'n seal StormBond
Interdependent
58
54
Trim Lock
Aluminum
concrete
Roof Tile Adhesive
galvanized, Gahralume°,
day or
Touch'n Seal Stormaond
Interdependent
58
54
Trim Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, LLC Evaluation Report E10240.08.08-R4
Ft1
Revision 4:
&xtWmw ajAuthonwdon #9503 03/17/2015J2035
Page 4 of 7
`�. TRINITY 4 ERD
i
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2022 (04-12), not greater than the following values. Refer to the file
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual file is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part file adhesives. This method is limited
to 2-part the adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each Individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the file head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
... .:..... , :...... . �......... em,.., i •!f• `+�s a. :. c _,
•Ppp�R ANLEJi1Nln
•a;_1a:= r".u}:. -: a'::::.: _ - •'ric
yy�� FIO ;tyN=.1I�1 �NOEPENb�i1�rPADbIFF!i%►CEIVI'
:� ^: .: .:.. :... ... ....:.. .. zt ,. !:8•. YAW-.`:
r�
•:+.r: .,�;, '^•i :. ..i.V,ti��;1:
-DYAPP.LiED� ira::5- - 'f': r Wit. J'••.
.. •.:r. ...:z
.Sa, .r, y Y
.3�'• GlN: FSA�7•f!`.AiREIi' t;K".
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(psf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
clay or
3MTM 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
galvanized, Galvalumem, aluminum or
clay or
3MTM 2-Component Foam Roof
Independent
173
Trim Lock
stainlesssteel
concrete
Tile AdhesiveAH-160
galvanized, Galvalumem, aluminum or
clayor
3MTM 2-Component Foam Roof
Independent
p
178
Trim Lock Plus
stainlesssteel
concrete
Tile AdhesiveAH-160
.. .. -: .... .�:... .. .:...:..:d.t v•' u'u ^. •yt >s'.•N.I' "'L '
y13b, Fj>; V..Sn ..1.^ .,..2 .: b1'7a?d
a .
-2 r•P RM a6 !
4g Q.t
'.::YY
•,c'5.�:}., r.{ .:F3='3,:•:�y,':?�;`: may.' ,•.` :. i::.:::j:::;:
4END¢Iyrrp4D Y'P ., :
T oriS boi l J /li ;`li!> eiiiEn ,4nq hi .
4r. as1_st• :;ass:-:''••
.IREO..
4:f.'u:^G i`
� g,y.,�
�:•,:.+ :'}�Si'': _ ,5. :: 3i..Jl „,i4;•h::-1�:;�d"..,A..: !r;. F:y._.:.t!.ix�ii:
:: sGTit:d,ya' rch�e: �L:. .S.s. 5.'j,i•y:.::j!:;+ia�: ..g...;-!%. _F;',•'.s.,:...
i3� D1L:OF,:'SAFEi:Y.�A'f3fEAD1",fiPPfJED).:,. !t.: <Cx:r..;•r'd.�'�it;:.:,:
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(isi
Design
Metal Type
Type
Placement
Trim Lode or Trim
galvanized, Galvalumeo, aluminum or
day or
3MTM 2-Component Foam Roof
interdependent
98
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
galvanized, Galvalumem or stainless
clay or
3M'1' Foam Roof Tile Adhesive
Interdependent
110
Trim Lode
steel
concrete
RTA-1
clay or
3MTM Foam Roof Tile Adhesive
Interdependent
93
Trim Lock
aluminum
concrete
RTA-1
galvanized, Galvalumem, aluminum or
clay or
3MTM Foam Roof Tile Adhesive
Interdependent
93
Trim Lock Pius
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume® or stainless
clay or
TILE BOND- Roof Ile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
day or
TILE BOND- Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clayor
TiLE BOND- Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
galvanized, Galvalumeo or stainless
clayor
Touch'n Seal StormBond Roof
Interdependent
1-48
Trim Lock
steel
concrete
Tile Adhesive
day or
Touch In Seal StormBond Roof
interdependent
61
Trim Lock
Aluminum
concrete
Tile Adhesive
galvanized, Galvalumel, aluminum or
clayor
Touch Seal StormBond Roof
Interdependent
61
Trim Lock Plus
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08A8-124
CertUlcote of Aothorizatlon #9503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
r'•yh r"�'hy
� d
0
a�
'-,,,J TRINfTY ERD
6. INSTALLATION:
6.1 -The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min.11 ga. x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 64nch o.c. along both deck flanges. Fasteners shall be
positioned wainch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to setup prior to installation of roof tiles.
View of'Polyset AH160 Placement for Trim Lock Plus Channel Metal installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the the adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified `30/9W system or other FBC Approved roof underlayments listing approved
use of the subject file adhesive.
Exterior Research and Design, LLC. Evaluation Report E10240.06.0844
FL5374-R4
Crst{%kate ofAuthorhaffon #9503 Revision 4: 03/17/2015
Page 6 of 7
�,-,J TRINITY' ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturers Approved, published
installation instructions, subject to the limitations outlined In Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI'April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 OA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844, (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC Evaluation Report E10240.08.08-R4
FL5374-1114
Certificate ojAuthadzation N9503
Revision 4: 03/17/20157/203.5
Page 7 of 7