HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BUSSEY RESIDENCE
Builder Name:
Street: LOT 26 SKYMASTER STREET
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1860.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 1130.00 ft2
b. Frame - Wood, Adjacent
R=13.0 730.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1460.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1460.00 ft2
6. Conditioned floor area above grade (ft2) 1460
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(252.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 140
a. U-Factor: Sgl, U=0.70 192.00 ft2
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.65 . 60.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d> U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 7.524 ft.
Area Weighted Average SHGC: 0.288
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1460.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 1460.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.173 Total Proposed Modified Loads: 47.65
PASS
Total Baseline Loads: 48.15
I hereby certify that the plans and specifications covered by
Review of the plans and
OE'SxATp :•
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
y�ij��''� "- ,•�`_
with the Florida Energy Code.
'
PREP ED Ry.
DATE:
Before construction is completed
this building will be inspected for]y�"
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
r,),, , "S
with the Florida Energy Code.
GOb'yyE�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE GCOPY
3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: BUSSEY RESIDENCE
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1460
Lot #
Owner Name:
Total Stories: 1
Block/Subdi%ision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
LOT 26 SKYMASTER S
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type: Single-family
FL,
New/Epsting: New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp Heating
Design
Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1460 14600
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 1
224 2240 No 0
1
1 Yes
Yes
Yes
2 BATH 2
66 660 No 0
1 No
Yes
Yes
3 WIC 2
30 300 No 0
1 Yes
Yes
Yes
4 KITCHEN
144 1440 Yes 0
1 No
Yes
Yes
5 LAUNDRY
72 720 No 0
1 No
Yes
Yes
6 LIVING ROOM
384 3840 No 0
1 Yes
Yes
Yes
7 DINING
220 2200 No 0
1 Yes
Yes
Yes
8 BEDROOM 2
224 2240 No 0
1
1 Yes
Yes
Yes
9 BATH 1
66 660 No 0
1 No
Yes
Yes
10 WIC 1
30 300 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 1 30 ft 0
224 ftZ
1 0
0
2 Slab -On -Grade Edge Insulation
BATH 2 1 ft 0
66 ftZ
___
1 0
0
3 Slab -On -Grade Edge Insulation
WIC 2 6 ft 0
30 ftz
__e
1 0
0
4 Slab -On -Grade Edge Insulation
KITCHEN 1 ft 0
144 f?
____
1 0
0
5 Slab -On -Grade Edge Insulation
LAUNDRY 1 ft 0
72 ft2
1 0
0
6 Slab -On -Grade Edge Insulation
LIVING ROOM 21 ft 0
384 ftZ
1 0
0
7 Slab -On -Grade Edge Insulation
DINING 20 ft 0
220 ftz
____
1 0
0
3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT 5UMMARY CHECKLI5T REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab
-On -Grade Edge Insulation
BEDROOM 2 30 ft
0
224 ft2
--__
1
0
0
9 Slab -On -Grade Edge Insulation
BATH 1 1 ft
0
66 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
WIC 1 6 ft
0
30 ft2
1
0
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip Metal 1633 ft2
0 ft2
Light
0.2
No
0.9
No
0
26.6
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
150
1460 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
BEDROOM 1
30
Blown
224 ft2
0.1
Wood
2
Under Attic (Vented)
BATH 2
30
Blown
66 ft2
0.1
Wood
3
Under Attic (Vented)
WIC 2
30
Blown
30 ft2
0.1
Wood
4
Under Attic (Vented)
KITCHEN
30
Blown
144 ft2
0.1
Wood
5
Under Attic (Vented)
LAUNDRY
30
Blown
72 ft2
0.1
Wood
6
Under Attic (Vented)
LIVING ROOM
30
Blown
384 fF
0.1
Wood
7
Under Attic (Vented)
DINING
30
Blown
220 ft2
0.1
Wood
8
Under Attic (Vented)
BEDROOM 2
30
Blown
224 ft2
0.1
Wood
9
Under Attic (Vented)
BATH 1
30
Blown
66 ft2
0.1
Wood
10
Under Attic (Vented)
WIC 1
30
Blown
30 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space R-N/.qllle
Et In
Ft
In
Area
R-\/al-,e Fraction
Ahsnr
rrqr1P%
1
N
Exterior Frame - Wood
BEDROOM 1
13 14
0 10
0
140.0 ft2
0
0.25
0.2
0
2
W
Exterior Frame - Wood
BEDROOM 1
13 16
0 10
0
160.0 ft2
0
0.25
0.2
0
3
E
Garage Frame - Wood
BATH 2
13 11
0 10
0
110.0 ft2
0
0.25
0.2
0
4
S
Exterior Frame - Wood
WIC 2
13 6
0 10
0
60.0 ft2
0
0.25
0.2
0
5
E
Garage Frame - Wood
WIC 2
13 5
0 10
0
50.0 ft2
0
0.25
0.2
0
6
E
Garage Frame - Wood
KITCHEN
13 16
0 10
0
160.0 ft2
0
0.25
0.2
0
7
E
Garage Frame - Wood
LAUNDRY
13 8
0 10
0
80.0 ft2
0
0.25
0.2
0
8
W
Exterior Frame - Wood
LIVING ROO
13 21
0 10
0
210.0 ft2
0
0.25
0.2
0
9
E
Garage Frame - Wood
LIVING ROO
13 17
0 10
0
170.0 ft2
0
0.25
0.2
0
10
W
Exterior Frame- Wood
DINING
13 20
0 10
0
200.0 ft2
0
0.25
0.2
0
11
S
Exterior Frame - Wood
BEDROOM 2
13 14
0 10
0
140.0 ft2
0
0.25
0.2
0
12
W
Exterior Frame - Wood
BEDROOM 2
13 16
0 10
0
160.0 ft2
0
0.25
0.2
0
3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar
Belo w
13 E
14 N
15 E
Garage Frame - Wood
Exterior Frame - Wood
Garage Frame - Wood
BATH 1 13 11 0 10 0 110.0 ft2 0
WIC 1 13 6 0 10 0 60.0 ft2 0
WIC 1 13 5 0 10 0 50.0 ft2 0
0.25 0.2
0.25 0.2
0.25 0.2
0
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
N 1 Metal Low-E Single
W 2 Metal Low-E Single
W 8 Metal Low-E Single
W 10 Metal Low-E Single
S 11 Metal Low-E Single
W 12 Metal Low-E Single
Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in
Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in
Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in
Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in
Yes , 0.65 0.25 N 30.0 ft2 10 ft 0 in 1 ft 4 in
Yes 0.7 0.3 N 48.0 ft2 2 ft 0 in 1 ft 4 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
3358 ft2 3358 ft2 73 ft loft
13
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgI-A ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000445 1703.3 93.51 175.86 .3446
7
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split SEER: 16 29.4 kBtu/hr 882 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt
Conservation
1
Electric None
Garage 0.98 50 gal 62.3 gal 120 deg
None
3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
-- Supply --
V
--- Return--
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 140 ft2
Attic
14 ft2
Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coolin Jan Feb
Heating Jan Feb
Mar
Mar
Apr
Apr
May
May
Jun X Jul
Jun f Jul
Au
Aug
Sep
ri Se
[ ] Oct
[ ] Oct
Nov
Dec
Dec
Ventin Jan Feb
X
X Mar
[X
A r
[
Ma
Jun [ Jul
[ Au
Se
XNov
[X] Oct X
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Heating (WD) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 1
Default(8 Ibs/s .ft.
ft2
ft
0.3
WIC 1
Name:
Rating Compant:
3/5/2019 7:37 AM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BUSSEY RESIDENCE Builder Name:
Street: LOT 26 SKYMASTER STREET Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation, shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed tight fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind niOng and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Mates and walls or ceilings.
a. In addition, Inspection of log walls shall be in accordance with the provisions of [CC-400.
3/5/2019 7:37 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
29.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1460
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.688
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.288
14. Heating system: Capacity
27.0
c) Area
7c.
252.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: LOT 26 SKYMASTER STREET City/FL Zip: PORT ST LUCIE, FL
3/5/2019 7:37:48 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1