Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BUSSEY RESIDENCE Builder Name: Street: LOT 26 SKYMASTER STREET Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1860.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 1130.00 ft2 b. Frame - Wood, Adjacent R=13.0 730.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1460.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1460.00 ft2 6. Conditioned floor area above grade (ft2) 1460 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(252.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Sgl, U=0.70 192.00 ft2 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=0.65 . 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d> U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.524 ft. Area Weighted Average SHGC: 0.288 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1460.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1460.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.173 Total Proposed Modified Loads: 47.65 PASS Total Baseline Loads: 48.15 I hereby certify that the plans and specifications covered by Review of the plans and OE'SxATp :• this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance y�ij��''� "- ,•�`_ with the Florida Energy Code. ' PREP ED Ry. DATE: Before construction is completed this building will be inspected for]y�" compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. r,),, , "S with the Florida Energy Code. GOb'yyE� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE GCOPY 3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BUSSEY RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1460 Lot # Owner Name: Total Stories: 1 Block/Subdi%ision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT 26 SKYMASTER S Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Epsting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1460 14600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 1 224 2240 No 0 1 1 Yes Yes Yes 2 BATH 2 66 660 No 0 1 No Yes Yes 3 WIC 2 30 300 No 0 1 Yes Yes Yes 4 KITCHEN 144 1440 Yes 0 1 No Yes Yes 5 LAUNDRY 72 720 No 0 1 No Yes Yes 6 LIVING ROOM 384 3840 No 0 1 Yes Yes Yes 7 DINING 220 2200 No 0 1 Yes Yes Yes 8 BEDROOM 2 224 2240 No 0 1 1 Yes Yes Yes 9 BATH 1 66 660 No 0 1 No Yes Yes 10 WIC 1 30 300 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 1 30 ft 0 224 ftZ 1 0 0 2 Slab -On -Grade Edge Insulation BATH 2 1 ft 0 66 ftZ ___ 1 0 0 3 Slab -On -Grade Edge Insulation WIC 2 6 ft 0 30 ftz __e 1 0 0 4 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 144 f? ____ 1 0 0 5 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 72 ft2 1 0 0 6 Slab -On -Grade Edge Insulation LIVING ROOM 21 ft 0 384 ftZ 1 0 0 7 Slab -On -Grade Edge Insulation DINING 20 ft 0 220 ftz ____ 1 0 0 3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT 5UMMARY CHECKLI5T REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulation BEDROOM 2 30 ft 0 224 ft2 --__ 1 0 0 9 Slab -On -Grade Edge Insulation BATH 1 1 ft 0 66 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation WIC 1 6 ft 0 30 ft2 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1633 ft2 0 ft2 Light 0.2 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1460 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 1 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) BATH 2 30 Blown 66 ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 30 Blown 30 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 144 ft2 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 72 ft2 0.1 Wood 6 Under Attic (Vented) LIVING ROOM 30 Blown 384 fF 0.1 Wood 7 Under Attic (Vented) DINING 30 Blown 220 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOM 2 30 Blown 224 ft2 0.1 Wood 9 Under Attic (Vented) BATH 1 30 Blown 66 ft2 0.1 Wood 10 Under Attic (Vented) WIC 1 30 Blown 30 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space R-N/.qllle Et In Ft In Area R-\/al-,e Fraction Ahsnr rrqr1P% 1 N Exterior Frame - Wood BEDROOM 1 13 14 0 10 0 140.0 ft2 0 0.25 0.2 0 2 W Exterior Frame - Wood BEDROOM 1 13 16 0 10 0 160.0 ft2 0 0.25 0.2 0 3 E Garage Frame - Wood BATH 2 13 11 0 10 0 110.0 ft2 0 0.25 0.2 0 4 S Exterior Frame - Wood WIC 2 13 6 0 10 0 60.0 ft2 0 0.25 0.2 0 5 E Garage Frame - Wood WIC 2 13 5 0 10 0 50.0 ft2 0 0.25 0.2 0 6 E Garage Frame - Wood KITCHEN 13 16 0 10 0 160.0 ft2 0 0.25 0.2 0 7 E Garage Frame - Wood LAUNDRY 13 8 0 10 0 80.0 ft2 0 0.25 0.2 0 8 W Exterior Frame - Wood LIVING ROO 13 21 0 10 0 210.0 ft2 0 0.25 0.2 0 9 E Garage Frame - Wood LIVING ROO 13 17 0 10 0 170.0 ft2 0 0.25 0.2 0 10 W Exterior Frame- Wood DINING 13 20 0 10 0 200.0 ft2 0 0.25 0.2 0 11 S Exterior Frame - Wood BEDROOM 2 13 14 0 10 0 140.0 ft2 0 0.25 0.2 0 12 W Exterior Frame - Wood BEDROOM 2 13 16 0 10 0 160.0 ft2 0 0.25 0.2 0 3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 13 E 14 N 15 E Garage Frame - Wood Exterior Frame - Wood Garage Frame - Wood BATH 1 13 11 0 10 0 110.0 ft2 0 WIC 1 13 6 0 10 0 60.0 ft2 0 WIC 1 13 5 0 10 0 50.0 ft2 0 0.25 0.2 0.25 0.2 0.25 0.2 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 N 1 Metal Low-E Single W 2 Metal Low-E Single W 8 Metal Low-E Single W 10 Metal Low-E Single S 11 Metal Low-E Single W 12 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in Yes 0.7 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in Yes , 0.65 0.25 N 30.0 ft2 10 ft 0 in 1 ft 4 in Yes 0.7 0.3 N 48.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 3358 ft2 3358 ft2 73 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 1703.3 93.51 175.86 .3446 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None 3/5/2019 7:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- V --- Return-- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb Heating Jan Feb Mar Mar Apr Apr May May Jun X Jul Jun f Jul Au Aug Sep ri Se [ ] Oct [ ] Oct Nov Dec Dec Ventin Jan Feb X X Mar [X A r [ Ma Jun [ Jul [ Au Se XNov [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 Ibs/s .ft. ft2 ft 0.3 WIC 1 Name: Rating Compant: 3/5/2019 7:37 AM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BUSSEY RESIDENCE Builder Name: Street: LOT 26 SKYMASTER STREET Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation, shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed tight fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind niOng and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Mates and walls or ceilings. a. In addition, Inspection of log walls shall be in accordance with the provisions of [CC-400. 3/5/2019 7:37 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1460 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.688 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.288 14. Heating system: Capacity 27.0 c) Area 7c. 252.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: LOT 26 SKYMASTER STREET City/FL Zip: PORT ST LUCIE, FL 3/5/2019 7:37:48 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1