Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
9 Project Summary Job: wri htsoft Entire House y By: Mar05, 2019 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For. BUSSEY RESIDENCE LOT 26 SKYMASTER STREET, PORT ST LUCIE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15798 Btuh Structure 15929 Btuh Ducts 4209 Btuh Ducts 5942 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20007 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 20777 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3838 Btuh Ducts 1573 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft� 1460 1460 Equipment latent load 5411 Btuh Volume (ft3) 14600 14600 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 26189 Btuh Equiv. AVF (cfm) 110 56 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR4031L1 AHRI ref Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.2 kW Sensible cooling 20580 Btuh Heating output 17793 Btuh Latent cooling 8820 Btuh Temperature rise 17 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft- 2019-Mar-05 07:39:11 �- """" ' Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 �'C'A E:\Documnets\wrightsoft WAC\BUSSEY RESIDENCE.rup Calc = MJ8 Front Door faces: S +�- wrightsoft° Right-JO Worksheet Job: Entire House Date: Mar 05, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)q)osed wall Room height Room dimensions Room area Entire House 113.0 ft 10.0 ft 1460.0 ftz BEDROOM 1 30.0 ft 10.0 ft heat/cool 14.0 x 16.0 ft 224.0 ft2 Ty Construction number U-value (Btuh/f:2 °F) Or HTM (Btuh/ft5 Area (ft� or perimeter (ft) Load (Btuh) Area (ft5 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 . �� 12C zing 2 g azm Gr .owe 12C-Osw _ _ 0 050 0 650 0.091 rt �n_ s 2.55 18.20 2.55 2.55 �_ 1.96 1 11.E 1.96 1.93 200 30 .170 ___0 170 60 V 433 ___546 433 546 _ 333 _ W8 383 358 140 30 110 0 ' 280 _ 346 0 0 _�`_ 215 358- 0 0 --- W _ 200 30 0 0 0 0 11 Wj �--G C F 9�az nw,_clr_low_e� g 16B-30md� ,27A-tph ___ Q650 0_032 1 358 _ _,w_ _ _18.20 0_90 38 02 _�21.96 4.80 1 60 0._Od 730 192 1460 1_460 538 17. 1460 1371 -3494 1308 1053 4761 2336 0 160 48 112 2 285 8744. 219 1190, - 358 Q 224 224 T_224 30 201 1141- _ 113 _ 4297 6 c) AED excursion 2375 565 Envelope loss/gain 12428 11906 3327 2906 12 a) Infiltration b) Room ventilation 3370 0 923 0 895 0 245 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 3100 0 0 0 Subtotal (lines 6 to 13) 15798 15929 4221 3151 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 271/6 37% 0 0 0 15798 4209 0 0 0 15929 5942 27% 37% 0 0 0 4221 1125 0 0 0 3151 1176 Total room load Air required (cfm) 20007 9801 21871 9801 1262 5346 4327 194 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -+�- wr7ghtsoTt- Right -Suite® Universal 2018 18.0.31 RSU08101 2019-Mar-05 07Page1 1 E:\Documnets\WrightsoftWAC\BUSSEYRESIDENCE.rup Calc = MJ8 Front Door faces: S +� wrightsoft° Right-JO Worksheet Job: Entire House Date: Mar 05, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area BATH 2 0 ft 10.0 ft heat/cool 6.0 x 11.0 ft 66.0 ftz WIC 2 6.0 ft 10.0 ft heattcool 6.0 x 5.0 ft 30.0 ftz TY Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft� Area (ftz or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 _ 12C-Osw 2 glazing, Gr IOw=e 12C-0sw 2-glazinq. clr lov-e 12C-Osw ` 0 091 0 650 0.091 0.650 0.091 0.650 n _n_ s s w _w_- 2:55 i18.20 2.55 18.20 2:55 —.18.20 '— 1.96 11.93 1.96 11 93 1.96 ._._._24.80 '6 0 0_ O 6_ 0 0 0_ 0 0 60 0 0 0 0 0 0 0 117 0 W W L—G..2:glazing,_clr_law_e.— 0 0 0 0 0 0 0 0 60 0 153 0 p 0 0 0 0 0 0� 0 0 0 0 0 0 "— 0 0 __ _0 __0. C _ _ ,F 16B 30md 22A:tph .' _ 0 032 1r358 - 0_90 38.02 1.60 ;0.00 _, 66 66 _ _ 66 __0 59 0 106 . 0 30 30 30 6 27 228 T 48 _ Q 6 c) AED excursion 0 0 Envelope loss/gain 59 106 408 165 12 a) Infiltration b) Room ventilation 0 0 0 0 179 0 49 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 250 0 0 250 Subtotal (lines 6 to 13) 59 3561 587 464 14 151 Less extemal load Less transfer Redistribution Subtotal Duct loads 27% 37% 0 0 0 59 16 0 0 0 356 133 27% 370/6 0 0 0 587 156 0 0 0 464 173 Total room load Air required (cfm) I I _F 75 4 42 2 743 36 6 9 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. +�- =101%tsc ftz A Right -Suite® Universal 2018 18.0.31 RSU08101 2019-Mar-05 07Page a e12 EADocumnets\Wrightsoft WAC\BUSSEY RESIDENCE.rup Calc = MJ8 Front Door faces: S g +�- wrightsoft° Right-JO Worksheet Job: Entire House Date: Mar 05, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eq)osed wall Room height Room dimensions Room area KITCHEN O ft 10.0 ft heat/cool 9.0 x 16.0 ft 144.0 ft' LAUNDRY O ft 10.0 ft heat/cool 9.0 x 8.0 ft 72.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 � 12C-Osw " 2 glazing, clr low-e� 12C-0sw 2 glazino, Gr low-e _ 12C-0sw .2.glazing,_clr.low-e— 16B30md 22A_tph—_ ` '�— � 091 ��_ 0$50 0.091 0.650 0.091 —__0.650 4032 - 1.358 n _n._ s s w _w_ —T 2.55 _ 18.20 2.55 18.20 2.55 . 18.20 090 -$8. 02 s' 1.-96 _ 11,93 1.96 11.93 __ _. ' -6 ,v _0 0 0_ 0 0 0 -----o 0 0 --0 :--r0 0 0 — 0 _ 0 0 0 0--0 0 ---Q 0 0 --0 0 0 WI � '—G W _ 0 0 0 0 1.96 _-24.80 1.60 —0.90 _ _ P 0 .____0 144 _,_,. 144 0 0 144 _0 Y 0 0 _ 129 Q 0 W 0 0 0 0 G 0 _C .F — —0 230 0 —0 72 72 72 _ 65 ___.0. , 115 Q 0 --0 _ 6 c) AED excursion 0 0 Envelope loss/gain 129 230 65 115 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1600 0 0 500 Subtotal (lines 6 to 13) 129 1830 165 615 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 27% 37% 0 0 0 129 34 0 0 0 1830 683 27% 37% 0 0 0 65 17 0 0 0 615 230 Total room load Air required (cfm) 163 8 2513 113 E82 4 845 38 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. +- wr➢gFttsofto 2019-Mar-05 07:39:11 At& " Right -Suite® Universal 2018 18.0.31 RSU08101 Page 3 F-Mocumnets\Wrightsoft WAC\BUSSEY RESIDENCE.rup Calc = MJ8 Front Door faces: S +�- wrightsoft• Right-M Worksheet Job: Entire House Date: Mar 05, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LMNG ROOM 21.0 ft 10.0 ft heat/cool 1.0 x 384.0 ft 384.0 ftz DINING 20.0 ft 10.0 ft heat/cool 11.0 x 20.0 ft 220.0 ft' TY Construction number U-value (Btuh Wft -'F) Or HTM (Btuh/ftj Area (ftl or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 VN� 12C-Osw �2,glazing,_chlow,e „_ 12C-0sw 2 plazinq, Gr low a 12C-0sw Y .2 glazing,.clr_low-e— 16B-30md 22A3ph __ —` 0.091 0.650 0.091 0650 _ 0.091 T 0.650 0.932 1 358 n —n_ s s_ w _ _w_ = 2.55 18.20 2.55 _ 18,20 2.56 ._. 18.20 0.90 _-38.02 1.96 _ 11.R3 1.96 0 __,.__v0 0 0 0 ____----�-0 0 0 l' 162 —___2 384 ______21 0 __0 0 0 0 0 --0 0 0 0 0 0 0 0 —_,_0 0 0 _ W W , - C _ _F --0 0 0, 0 0_ _. 0 0 w11.93 1.9ti ' 24.80 1.60 —0.00 210 48 _ 384 384 413 �874 344 — T99 317 _ 1190 614 0 200 48 152 _2 387 87.4. 297 _�1190. 352 0 220 _220 220 20. 197 — 780 6 c) AED excursion 622 622 Envelope loss/gain 2429 2744 2218 2462 12 a) Infiltration b) Room ventilation 626 0 171 01 596 0 163 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 3055 2915 2815 2625 14 151 Less edemal load Less transfer Redistribution Subtotal Duct loads 27% 37% 0 0 0 3055 814 0 0 0 2915 1088 27% 37% 0 0 0 2815 750 0 0 0 2625 979 Total room load Air required (cfm) 3869 190 4003 179 3565 175 3605 162 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A- wr➢ghtsoft- 2019-Mar-05 07:39:11 Right -Suite® Universal 2018 18.0.31 RSUD8101 Page 4 E:\Documnets\Wrightsoft HVAC\BUSSEY RES]DENCE.rup Calc = MJB Front Door faces: S +�- wrightsoft° Right-JO Worksheet Job: Entire House Date: Mar 05, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@J\OL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BEDROOM 2 30.0 ft 10.0 ft heat/cool 14.0 x 16.0 ft 224.0 ftz BATH 1 0 ft 10.0 ft heat/cool 6.0 x 11.0 ft 66.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft5 Area (ft5 or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _ W __._ 12C-Osw � 2.glazing, plr_low_e a 12C-Osw 2,glazinq. clflow_ a 0.091 ___0.6.50 0.091 �' 0,650 n __n_ s s _ � 2.55 _ 18.20 2.55 18.20 ` 1:96 11.93 1.96 11:93 � 0 ______: 0 140 _ 30 ' 4' 0' 0 0 —'�- 0 0 —AO ___0 0 0 0 0 ' 0 0 0 . W `W— 110 30 __0 280 _ 546 215 358 0 0 0 0 11 ��..2.glazing,-clr_low_ev C F_ 1'2C-Osw 16B-30md '0.091 --0.650 0_032 1._$58 w _w__ = 2.56 — 18.20...-24.80 0 90 �38.02 1.86 1.60 0.00 16d 48 224 224 112 __s2 224 30 285 __87_4 201 1141. 2f 9 -1190 358 0 6 � _0 66 0 ___0 66 0 0 _0 59 Q 0 _0. _ 106 - 0, 22Q-tph _ 65 _ 6 c) AED excursion 565 0 Envelope loss/gain 3327 2906 59 106 12 a) Infiltration b) Room ventilation 895 0 245 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliancestother 0 0 0 0 0 250 Subtotal (lines 6 to 13) 4221 3151 59 356 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 127% 37% 0 0 0 4221 1125 0 0 0 3151 1176 27% 37% 0 0 0 59 16 0 0 0 356 133 Total room load Air required (cfm) 5346 2621 4327 194 75 4 488 22 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. A— wrighttsof- 2019-Mar-05 07:39:11 A&k"'""'-' """" Right -Suite® Universal 2018 18.0.31 RSU08101 Page 5 E:\Documnets\Wrightsoft WAC\BUSSEY RESIDENCE.rup Calc = MJ8 Front Door faces: S +� wrightsoft Right-M Worksheet Job: Entire House Date: Mar 05, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC 1 6.0 ft 10.0 ft heat/cool 6.0 x 5.0 ft 30.0 ft2 TY Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W 12CZs7w Zglazing, cIr_low_e__ 12C-0sw -2 plazino, clr low_e 12C-0sw - 0.091 0 85.0 0.091 0_650 0.091 0.650 n _,n — s s w' —w_ 2.55 . 18.20. 2.55 18.20 2.55 —18.20 1.96 11.9.3 1.96 11:93 66 0 60 153 0 117 Q _ W --G W �..2.glazing,_clr-low:e— -C F __,. 0 0 .�_____0 0 0 0 0 _ _ 0 0 _ 1.96 —24.80 , 0 0 0 0 0 _0 0 __0 16B30md -A 22 ph .._ 0_032 1.358 _z_ 38.02, m_ 0.00 30 v6 228 0 6 c) AED excursion 0 Envelope loss/gain 408 165 12 a) Infiltration b) Room ventilation 179 0 49 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 250 Subtotal (lines 6 to 13) 587 464 14 15 Less eQemal load Less transfer Redistribution Subtotal Ductloads 27% 37% 0 0 0 587 156 0 0 0 464 173 Total room load Air required (cfm) 743 36 638 29 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. A_ wr➢01mt5oft- ,&k Right -Suite® Universal 2018 18.0.31 RSU08101 2019-Mar-05 07Page a e16 E:\Documnets\Wrightsoft H\/AC\BUSSEY RES]DENCE.rup Calc = MJ8 Front Door faces: S g + wrightsoft- Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. BUSSEY RESIDENCE LOT 26 SKYMASTER STREET, PORT ST LUCIE, FL Job: Date: Mar 05, 2019 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 980 cfm 980 cfm Total effective length (TEL) 177 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 1 c 488 4 22 1.000 4.0 Ox 0 VIFx 39.3 135.0 st3 BATH 2 c 488 4 22 1.000 4.0 Ox 0 VIFx 20.3 115.0 st1 BEDROOM 1 h 5346 262 194 1.000 8.0 Ox0 VIFx 37.7 135.0 st3 BEDROOM 2 h 5346 262 194 1.000 8.0 Ox0 VIFx 21.2 115.0 st1 DINING h 3565 175 162 1.000 6.0 Ox0 VIFx 18.6 115.0 st2 KITCHEN c 2513 8 113 1.000 5.0 Ox0 VIFx 24.8 115.0 st2 LAUNDRY c 845 4 38 1.000 4.0 Ox0 VIFx 20.8 115.0 st2 LIVING ROOM h 3869 190 179 1.000 7.0 Ox 0 VIFx 7.8 95.0 WIC 1 h 743 36 29 1.000 4.0 Ox 0 VIFx 41.8 135.0 st3 WIC 2 h 743 36 29 1.000 4.0 Ox0 VIFx 26.3 115.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 302 244 1.000 683 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 489 556 1.000 708 12.0 0 x 0 VinlFlx st1 Peak AVF 302 244 1.000 683 9.0 0 x 0 VinlFlx +k- wrigt,ttsoft, 2019-Mar-05 07:39:12 .•'~� >u Win^ �^-+ Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 �� E:\Documnets\Wrightsoft HVAC\BUSSEY RESIDENCE.rup Calc = MJB Front Door faces: S Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 980 980 0 0 0 0 Ox 0 VIFx -- wrightsoft- i.'� Right -Suite® Universal 2018 18.0.31 RSU08101 ACC*t E:\Documnets\Wrightsoft WAC\BUSSEY RESIDENCE.rup Calc = MJ8 Front Door faces: S KII IT IT, PA Page 2