Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Loads
ASCE 7-10 Design Wind Loads Winds 'speed V= 160 mph Ex osure 'D t � Easy Sea IS 9 P P P - For Wall Components & Cladding ASD Load Combination Coefficient: 0.6 easyseals.corin i " Wind Pressures[psf]For use with Allowable Stress Design KZt= 1.0 Kd= 0.85 Enclosed Bldg GCpi= 0.18 Triburary area at least... Triburary area at least... Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Mean 10sgft 15sgft 20sgft 25sglit 30sgft 35sgft 40sgft 50sgft Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 'I Height Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner 60'to: + - + - + - + - + - + - + - + - + - + - + - + - + - + I - + I - + I - 61 ft +47.5-47.5 +47.5-87.0 +47.5-47.5 +47.5-87.0 +47.5-47.5 +47.5-87.0 +46.5-46.9 +46.5-84.6 +45.8-46.4 +45.8-82.6 +45.2-45.9 +45.2-80.9 +44.6-45.6 +44.6-79.4 +43.7-45.0 +43.7-77.0 65 ft +48.0-48.0 +48.0-88.0 +48.0-48.0 +48.0-88.0 +48.0-48.0 +48.0-88.0 +47.1-47.4 +47.1-85.5 +46.3-46.9 +46.3-83.5 +45.7-46.4 +45.7-81.8 +45.1-46.1 +45.1-80.3 +44.2-45.5 +44.2-77.9 i 70 ft +48.6-48.6 +48.6-89.1 +48.6-48.6 +48.6-89.1 +48.6-48.6 1 +48.6-89.1 +47.7-48.0 +47.7-86.6 +46.9-47.5 +46.9-84.6 +46.3-47.0 +46.3-82.9 +45.7-46.7 +45.7-81.4 +44.8-46.0 +44.8-78.9 I I 75 ft -+49.2-49.2 .+49.2-90.2 +49.2-49.2 +49.2-90.2 +49.2-49.2 +49.2-90.2 +48.3-48.6 +48.3-87.7 +47.5-48.0 +47.5-85.6 +46.8-47.6 +46.8-83.9 +46.3-47.2 +46.3-82.3 +45.3-46.6 +45.3-79.8 80 ft +49.8-49.8 +49.8-91.2 +49.8-49.8 +49.8-91.2 1 +49.8-49.8 +49.8-91.2 +48.8-49.1 +48.8-88.7 +48.0-48.6 +48.0-86.6 +47.4-48.1 +47.4-84.8 +46.8-47.8 +46.8-83.3 +45.8-47.1 +45.8-80.7 - 85 ft +50.3-50.3 +50.3-92.2 +50.3-50.3 +50.3-92.2 +50.3-50.3 +50.3-92.2 +49.3-49.6 +49.3-89.6 +48.5-49.1 +48.5-87.5 +47.9-48.7 +47.9-85.7 1 +47.3-48.3 +47.3-84.2 1 +46.3-47.6 +46.3-81.6 90 ft +50.8-50.8 +50.8-93.1 +50.8-50.8 +50.8-93.1 +50.8-50.8 +50.8-93.1 +49.8-50.1 +49.8-90.5 +49.0-49.6 +49.0-88.4 +48.3-49.1 +48.3-86.6 +47.7 48.8 +47.7-85.0 +46.8-48.1 1 +46.8-82.4 95 ft +51.3-51.3 +51.3-94.0 +51.3-51.3 +51.3-94.0 +51.3-51.3 1 +51.3-94.0 +50.3-50.6 +50.3-91.3 +49.5-50.1 +49.5-89.2 +48.8-49.6 +48.8-87.4 +48.2-49.2 +48.2-85.8 +47.2-48.6 +47.2-83.2 100 ft +51.7-51.7 +51.7-94.8 +51.7-51.7 +51.7-94.8 +51.7-51.7 +51.7-94.8 +50.7-51.1 +50.7-92.2 +49.9-50.5 +49.9-90.0 +49.2-50.1 +49.2-88.2 +48.6-49.7 +48.6-86.6 +47.6-49.0 +47.6-83.9 105 ft 1 +52.2-52.2 +52.2-95.6 +52.2-52.2 +52.2-95.6 1 +52.2-52.2 +52.2-95.6 1 +51.2-51.5 +51.2-93.0 1 +50.3-50.9 +50.3-90.8 +49.6-50.5 +49.6-88.9 +49.0-50.1 +49.0-87.3 +48.0-49.4 +48.0-84.6 � 110 ft +52.6-52.6 +52.6-96.4 +52.6-52.6 +52.6-96.4 +52.6-52.6 +52.6-96.4 +51.6-51.9 1 +51.6-93.7 +50.7-51.4 +50.7-91.5 +50.0-50.9 +50.0-89.6 +49.4-50.5 +49.4-88.0 +48.4-49.8 +48.4-85.3 115 ft +53.0-53.0 +53.0-97.2 +53.0-53.0 +53.0-97.2 +53.0-53.0 +53.0-97.2 +52.0-52.3 +52.0-94.4 +51.1-51.8 +51.1-92.2 +50.4-51.3 +50.4-90.3 +49.8-50.9 1 +49.8-88.7 +48.8-50.2 1 +48.8-86.0 120 ft +53.4-53.4 +53.4-97.9 +53.4-53.4 +53.4-97.9 +53.4-53.4 1 +53.4-97.9 +52.4-52.7 +52.4-95.1 +51.5-52.1 +51.5-92.9 +50.8-51.7 +50.8-91.0 +50.2-51.3 +50.2-89.4 +49.2-50.6 +49.2-86.6 125 ft +53.8-53.8 +53.8-98.6 +53.8-53.8 +53.8-98.6 +53.8-53.8 +53.8-98.6 +52.7-53.1 +52.7-95.8 +51.9-52.5 +51.9-93.6 1 +51.2-52.0 +51.2-91.7 +50.6-51.6 +50.6-90.0 +49.5-50.9 +49.5-87.2 130 ft 1 +54.1-54.1 +54.1-99.3 1 +54.1-54.1 1 +54.1-99.3 1 +54.1-54.1 +54.1-99.3 1 +53.1-53.4 +53.1-96.5 1 +52.2-52.9 +52.2-94.2 +51.5-52.4 +51.5-92.3 +50.9-52.0 +50.9-90.6 +49.9-51.3 +49.9-87.8 135 ft +54.5-54.5 +54.5-99.9 +54.5-54.5 +54.5-99.9 +54.5-54.5 +54.5-99.9 +53.4-53.8 +53.4-97.1 +52.6-53.2 +52.6-94.8 +51.9-52.7 +51.9-92.9 +51.2-52.3 +51.2-91.2 +50.2-51.6 +50.2-88.4 140 ft +54.8-54.8 +54.8-100.5 +54.8-54.8 +54.8-100.5 +54.8-54.8 +54.8-100.5 +53.8-54.1 +53.8-97.7 +52.9-53.6 +52.9-95.4 +52.2-53.1 +52.2-93.5 1 +51.6-52.7 +51.6-91.8 +50.5-51.9 +50.5-89.0 1 +55.2-55.2 +55.2-101.2 +55.2-55.2 +55.2-101.2 +55.2-55.2 1 +55.2-101.2 +54.1-54.5 +54.1-98.3 +53.2-53.9 1 +53.2-96.0 +52.5-53.4 +52.5-94.0 +51.9-53.0 +51.9-92.4 +50.8-52.3 + 50 ft +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +54.4-54.8 +54.4-98.9 +53.6-54.2 +53.6-96.6 +52.8-53.7 +52.8-94.6 +52.2-53.3 +52.2-92.9 +51.1-52.6 +51.1-90.0 .8 9+55.8-102.3 +55.8-55.8 +55.8-102.3 5.8-102.3 +54.7-55.1 +54.7-99.5 -53.6 +52.5- 3.4 +5 1 +55 -55.8 - 160 ft +56.1-56.1 +56.1-102.9 +56.1-56.1 +56.1-102.9 +56.1-56.1 +56.1-102.9 +55.0-55.4 1 +55.0-100.0 +54.2-54.8 +54.2-97.7 +53.4-54.3 +53.4-95.7 +52.8-53.9 +52.8-93.9 +51.7-53.2 +51.7-91.1 165 ft 1 +56.4-56.4 +56.4-103.5 +56.4-56.4 +56.4-103.5 +56.4-56.4 1 +56.4-103.5 +55.3-55.7 +55.3-100.6 +54.5-55.1 +54.5-98.2 +53.7-54.6 +53.7-96.2 1 +53.1-54.2 +53.1-94.5 +52.0-53.5 +52.0-91.6 j 170 ft +56.7-56.7 +56.7-104.0 +56.7-56.7 +56.7-104.0 +56.7-56.7 +56.7-104.0 +55.6-56.0 +55.6-101.1 +54.7-55.4 +54.7-98.7 +54.0-54.9 +54.0-96.7 +53.3-54.5 +53.3-94.9 +52.2-53.7 +52.2-92.0 f175 ft +57.0-57.0 +57.0-104.5 +57.0-57.0 +57.0-104.5 +57.0-57.0 +57.0-104.5 +55.9-56.3 +55.9-101.6 +55.0-55.7 +55.0-99.2 +54.3-55.2 +54.3-97.2 +53.6-54.7 +53.6-95.4 +52.5-54.0 1 +52.5-92.5 180 ft +57.3-57.3 +57.3-105.0 +57.3-57.3 +57.3-105.0 +57.3-57.3 +57.3-105.0 +56.2-56.6 +56.2-102.1 +55.3-56.0 +55.3-99.7 +54.5-55.4 +54.5-97.7 +53.9-55.0 +53.9-95.9 +52.8-54.3 1 +52.8-92.9 185 ft +57.6-57.6 +57.6-105.5 +57.6-57.6 +57.6-105.5 +57.6-57.6 +57.6-105.5 +56.5-56.8 1 +56.5-102.6 +55.6-56.2 +55.6-100.2 +54.8-55.7 +54.8-98.1 +54.1-55.3 +54.1-96.3 +53.0-54.5 +53.0-93.4 190 ft 1 +57.8-57.8 +57.8-106.0 +57.8-57.8 +57.8-106.0 +57.8-57.8 1 +57.8-106.0 +56.7-57.1 +56.7-103.1 +55.8-56.5 +55.8-100.6 +55.0-56.0 +55.0-98.6 +54.4-55.5 +54.4 96.8 +53.3-54.8 +53.3-93.8 195 ft +58.1-58.1 +58.1-106.5 +58.1-58.1 +58.1-106.5 +58.1-58.1 +58.1-106.5 +57.0-57.3 +57.0-103.5 +561 567 +56.1-101.1 +553-56.2 +55.3-99.0 +546-55.8 +54.6-97.2 +53.5-55.0 +53.5-94.3 -107.0 +57.2-57.6 +57.2-104.0 +56.3-1015 -56.5 +55.5-99.5 9-56.0 +54.9-97.7 +53.7-55.3 +53.7-94.7200 ft +58.4- 8.4 +58.4-107.0 +58.4-58.4 +58.4-107.0 +58.4 58.3 +58.4 +55.5 7 ; In •Design conforms to the Florida Building Code 6th Ed(2017). •Wind Speed noted above Is ultimate design wind speed(3-second gust). •Zones 4&5("Interior"and"corner"zones,respectively)areas shown to a a Valid only wi ngineer's Fw-� •Tabulated design wind loads are based on ASCE 7-10 specifications for •Plus(+)&minus(-)signs signify pressures acting toward and away from the right,where the dimension"a"Is the minimum of 10%of the building's signature&ra ed seal iO components and cladding based on design criteria as noted herein. the exterior component or cladding surface,respectively. least horizontal dimension or 40%of the mean roof height,but never less �j_ _Z •Where this document Is used for permit,applicability of design criteria •Where"Mean(average)Roof Height"cannot be determined,peak roof than 3'-0"or4%of the least horizontal dimension. f J noted herein(Basic Wind Speed,Exposure Categdry,-Risk-Category,-etc.) height shall be used,except that eave height shall be used for roof angle •This specification Is valid only for use With structures NOT located In the i Zone_ 15 -- -- - ' ,.� `f shall be verified by the contractor&building official prior to construction. less than or equal to 10'. Round up to values shown upper one-half of an isolated hill,ridge or escarpment. NOV = •This specification may be used in conjunction with engineering under •Wind pressures are applicable to all building floors. •This specification Is valid for use with buildings of any Risk Category, LJ.I separate certification(by this engineer or by others)using Allowable Stress •Tabulated wind pressures are valid for all roof slopes;no reduction for Including essential facilities and buildings or other structures that WDesign(ASD). roof slope 510"has been considered. represent a substantial hazard to human life in the event of failure. Christian Langl PE U •Refer to the above-noted ASCE 7 standard for descriptions and •Tributary Area noted In table(effective wind area)Is equal to the •Design Is based on structure classification as Enclosed Bldg FL PE#67382 WA#31124 definitions of all design criteria. minimum of[height x width]or[ht x ht/3].Round down to values shown. wa i c�evennrr i 1200 N Federal Hwy,6200,Boca Raton,FL 33432 Copyright©2019 Easy Seals rev 1119 Doc No.A10MS.160D i' I ' i I Customer: MAHER WorkOrder Number: 06042020002NO301 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -90 636.25 98.25 636.25 98.25 95 3"o.c. - 3"o.c. I i