Loading...
HomeMy WebLinkAboutHealth Department Septic Approval C12-6-10.) -oqz* STATE OF FLORIDA • APPLICATION # AP1468331 DEPARTMENT OF HEALTH PERMIT # 56-SF-2039924 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT # SE1254848 SITE EVALUATION AND SYSTEM SPECIFICATION — APPLICANT: Gregory Johnson CONTRACTOR / AGENT: George&Assoc, LLC LOT: 1.2.3 BLOCK: A SUBDIVISION: Sumner Heights ID#: 2405-704-0001-000-7 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR 'OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.53 ACRES TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER-TABLE 2 ] AUTHORIZED SEWAGE FLOW: 1325.01 GALLONS PER-DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: orange paint spot on NE corner of catch basin NE property corner ELEVATION OF PROPOSED SYSTEM SITE 6.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 100+ FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON-POTABLE: 63 FT BUILDING FOUNDATIONS: 7 FT PROPERTY LINES: 14 FT POTABLE WATER LINES: 67 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X ]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES:Tantile sand USDA SOIL SERIES:Tantile sand Munsell#/Color Texture Depth Munsell#/Color Texture Depth 10YR 4/2 Sand 0 To 16 10YR 6/1 Sand 0 To 17 10YR 5/2 Sand 16 To 22 10YR 4/1 Sand 17 To 49 10YR 5/1 Sand 22 To 30 10YR 4/1 Gravel 32 To 38 10YR 6/1 Sand 26 To 34 10YR 5/1 Sand 49 To 58 10YR 2/1 Spodic Material 34 To 41 10YR 6/1 Sand 58 To 67 7.5YR 3/3 Sand 41 To 45 10YR 3/1 Sand 67 To 72 10YR 4/3 Sand 45 To 57 10YR 3/3 Sand 57 To 72 OBSERVED WATER TABLE: INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 26 INCHES [ ABOVE /BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X ]NO MOTTLING: [X ]YES [ ]NO DEPTH: 26.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION: 41 INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. 10YR 611 stripping in 10YR 5/1 matrix>10%with diffuse boundaries starting at 26"in SB1. SB1 6"above BM. S132 6"above.BM. SITE EVALUATED BY: DATE: 02/25/2020 Collier,Hunter(Title:Environmental Specialist 1)(Florida Department of Health in St.L DH 4015, 08109 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 AP1468331 EID2039924 v 1.0.2