HomeMy WebLinkAboutCarports Anywhere - S Frechette - 243416-Rev1 - Digital Sealed0
I
r----3'-1116"��2'-6
i
I NDOW
SWINGING
DOOR
WINDOW
-------------------------------
-3167
WIN
WINDOW
7„
- 316
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND
BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD
LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING
DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED
BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS
ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2.
4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15.
5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE
RESPONSIBILITY OF THE OWNER.
6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX.
7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS.
8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER.
9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH.
10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL.
Vry I tJ:
SUB —GRADE SOILS:
—TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION
R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION
CONCRETE:
—MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
—ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE
DESIGNED TO SLOPE AWAY FROM THE STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
—MINIMUM GRADE 40 STEEL
—REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
—THE REBAR IS BENT COLD
—THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED
6—BAR DIAMETERS: AND
—REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT
EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL
CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
—COVER:
—2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY
IN CONTACT WITH SOIL OR WEATHER, AND 11" ELSEWHERE. REBAR EMBEDDED IN
GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF 4" FOR FINE
GROUT, AND I" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL.
REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING
GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO
EARTH OR WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR
WEATHER.
GALVANIZATION:
—METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY
EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153,
CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
4"x54" EXPANSION ANCHOR WITHIN 6"
OF EACH POST/TRUSS ALONG SIDES
AND EVERY OTHER END —WALL POST
2" MIN. --I H-F -BASE RAIL
-2'- 6 "---t-3' -1 116
WINDOW
i
i
N
I
i
i
i
i
I
i
WINpoW CO
I N
III —III —III —I I
—� III—o 2,500 PSI 4" CONCRETE
III— a SLAB WITH 10GA. W.W.F.
I-12" OR FIBER MESH
I
CNUSIUMINIMUM SOIL BEARING ONIUOWIT MINMM
CAPACITY 500 PSF(TYP.) 12" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
2 5" PLAN VIEW DOOR FRAMING
I if J" RECESS
4 DOOR WIDT'I
ELEVATION VIEW
DOOR FRAMING
RECESS
T
.75"J 4„ DOOR WIDTH
OPTIONAL ROLL -UP DOOR
CONCRETE SPLASH -GUARD RECESS
MIN. 2,500 PSI 4" CONCRETE SLAB WITH 10GA. W.W.F. (OR
FIBER MESH) AND 12"02" REINFORCED FOOTER PERIMETER 12"" x12REINFORCED FOOTER
----------------------------- W----------------------------------------------------------------------------------------------Rfl�
tt=I-------
_______________________________________________
WINDOW FRONT DOOR
3'-9" -I- 2'-6" -I- 3'-9" -;- 20'-0" - I - 41011
34'-0"
r-100
I
O
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
CODE VERSION IFBC 2017 6th Edition,ll
MANUFACTURER
.1—
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
INONE
OCCUPANCY
JUTILITY, U
WIND SPEED
Vult-150mph
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1816 SQ. FT.
REVISIONS
REV I DESCRIPTON DATE I BY
1 IVERTICAL SIDES 8/20/20 1 MTB
-"I" o,. MTB
DATE: 8/ 14/20
LocA110N: 5607 Birch Dr., Ft. Pierce
SIZE: 24'L X 34'W X 16'H
A, \,\CENsF
e NO. 64608 : 2
STATE OF 44/
i�OiC� F L O R 10 N 4(j`�
/ ///01111111��� `
N
Digitally signed
by Matthew
Baldwin
Date:2020.08.20
16:45:17-04'00'
z MattheW T. BaldWin P.E.
Q Florida License #64608
Li _ J
Sheet: CA-1 OF 4
'o 2
WINDOW
1
N
ROLL -UP
DOOR
m
FRONT END WALL
2'-6"
WINDOW
WINDOW
WINDOW
REAR END WALL
O.C.
CAMMSANYMME
CODE INFORMATION
CODE VERSION
FBC 2017 6th Edition,
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
z —s"
WINDOW
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-150mph
o
EXPOSURE
B
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 300Ib P.L.
FLOOR DEAD LOAD
10PSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
3'-11
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1816 SQ. FT.
REVISIONS
REV
DESCRIPTON
DATE
I BY
1
IVERTICAL SIDES
1 8/20/201
MTB
Uw WN CT: MTB
DATE: 8/ 14/20
LOCAnON: 5607 Birch Dr., Ft. Pierce
SIZE: 24'L X 34'W X 16'H
O.C. MAX.
I
I
WINDOW I
N
N WINDOWCn
SWINGING
—2
—2
>
DOOR
3'-0"
0
z
11 �"
11 3'-11
Q
24-0"
LEFT SIDE WALL
RIGHT SIDE WALL
z
w
Matthew T. Baldwin P.E.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND
w
Florida License #64608
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
Sheet: CA-2 OF 4
WINDOW
DOOR
FRONT END WALL
WINDOW
LEFT SIDE WALL
SWINGING
DOOR
I ►i 1 ►1��11,
WINDOW
WINDOW
WINDOW
o
o
CODE VERSION
FBC 2017 6th Edition,
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-150mph
EXPOSURE
B
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
10PSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
816 SQ. FT.
REVISIONS
REV
DESCRIPTON
DATE
BY
1
VERTICAL SIDES
8/20/20
MTB
34'-o"
REAR END WALL
WINDOW
24,-0"
RIGHT SIDE WALL
PRINTED COPIES OF THIS DOCUMENT ARE
THE SHA AUTHENTICATION CODE MUST BE
0
i
WINDOW
NOT CONSIDERED SIGNED AND SEALED AND
VERIFIED ON ANY ELECTRONIC COPIES
DRAWN BY: MTB
DATE: 8/ 14/20
LOCAnON: 5607 Birch Dr., Ft. Pierce
SIZE: 241 X 34'W X 16'H
LLB
i
z
W
W
Matthew T. Baldwin P.E.
Florida License #64608
Sheet: CA-3 OF 4
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14x4" SELF —DRILLING
SCREWS
41/ NIPPLE TO
�\ BASE RAIL NIPPLE
BASE I
POST TO BASE RAIL
CONNECTION
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14x�"
SELF —DRILLING SCREWS
NON-STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
INTERIOR
#12-14xj" SELF —DRILLING
SCREWS ® 10" O.C. MAX.,
3" MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX.
FROM CORNERS VERTICALL`
EXTERIOR
DOOR FRAME TO POST
CONNECTION
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xi" SELF —DRILLING
SCREWS
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF —DRILLING SCREWS
It
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF —DRILLING SCREWS
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF —DRILLING SCREWS
SINGLE OR DOUBLETS
HEADER
INTERMEDIATE POST TO
END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION
CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1
2"x2"x2" 16 GA. ANGLE CLIP SECURED
WITH (4) #12-14xi" SELF —DRILLING
SCREWS 26 GAUGE ROOF SHEATHING SECURED WITH
VARIES (1)#12-14x4" SELF —DRILLING SCREWS ® NIPPLE\
IITD. MAX.-1-2-1' (6" O.C. (9" O.C. MAX.)) TO TRUSS/
IIS�3SPM NNG
�48" MAX•
1$"
STD. MAX. SP*CING
R I ES
SIDE WALL ROLL —UP
DOOR/FRAME OUT
HEADER DETAIL
INSTALL PER MANUFACTURERS INSTRUCTIONS
#140" SELF —DRILLING
SCREWS ® 6" O.C. MAX. TYP.,
& 6" MAX. FROM CORNERS
ROLL -UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
- 150 Mph
ROOF
+19.3/-41
.4
WALLS
+20.0/-22.2
DOORS
+20.0/-22.2
WINDOWS
+20.0/-22.2
1
2
3
4
5
ZONE
+9.3
-21.9
+12.3
-35.1
+19.3
-41.4
+18.8
-21.9
+20.0
-22.2
1" 16 GAUGE FURRING CHANNEL
48" O.C. MAX. SECURED WITH
(2)#12-14x1" SELF —DRILLING
SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
15" TRUSS CONE SECURED TO
WALL POST WITH (4)#12-14xi"
SELF —DRILLING SCREWS
40' BOX SAVE RAFTER TO
POST CONNECTION DETAIL
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
LE T
: RAI
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH dgm
(4)#12-14x" SELF —DRILLING SCREWS cmIM
SINGLE OR DOUBLETS
HEADER CONNECTION DETAIL
OPTION 2
MINIMUM 6" TS NIPPLE.
NIPPLE SECURED TO WALL
POST WITH (4)#12-14xj"
SELF —DRILLING SCREWS
POST TO TRUSS
CONNECTION
RAFTER CONNECTION
DETAIL
4" WELD @
2' O.C. MAX.
DOUBLE POST/
DOUBLE BASE RAIL
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1 — R 1
Hampton Rib Roof Panel
WALL SHEATHING
Carports Anywhere
FL27403.1
Hampton Rib Wall Panel
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
407 STEEL DOOR
ROLL —UP DOOR
JANUS INTERNATIONAL CORPORATION
FL21450.3
SERIES 3100
WINDOW
POCOHONTAS ALUMINUM COMPANY, INC.
FL12940—R5
MODEL 10OVS
CODE VERSION
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
VUIt-15Gmph
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
816 SQ. FT.
REVISIONS
REV DESCRIPTON DATE I BY
1 IVERTICAL SIDES 8/20/20 1 MTB
.-W., o'' MTB
DATE: 8/14/20
LOCATION: 5607 Birch Dr., Ft. Pierce
SIZE: 241 X 34'W X 16'H
J
Q Matthew T. Baldwin P.E.
Florida License #64608
Li; LJ
c) Sheet:
CA-4 OF 4