Loading...
HomeMy WebLinkAboutCompaction test Headquarters 1 Ar ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958ANw OVA AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: May 13, 2020. KSM JOB#: 202248-1d/CH/jo PERMIT#: 1908-0262 NUC# 417 CONTRACTOR: Adams Homes Nuc Model: 3500 JOB LOCATION: 8529 Waterstone Blvd Nuc Serial#: 3417 Lot 40-2,Waterstone Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION DEPTH PEN DRY MAX.DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE(P.C.F) COMPACTION 1. N.E. 0"-12" 45 110.3 111.9 98.6% 2. S.E. . 44 109.4 97.8% 3. Center 40 109.0 97.4% 4. N.W. 44 109.9 98.2% 5. S.W. 45 110.1 98.4% Soil Description: 113.0 Brown Sand with some W Clay and Shell I I I I I I I I I I I In Place Moisture: G 112.o '— �—"—'�'—"_ 8.0% H I I I I I I T I . Proctor Optimum Moisture: 111.0 t— — !— — I — —� — —••J-••— 11.0% F, I I I Proctor Max. Dry Density:P.C.F. C I I I I I 111.9 110.0 F I I I I @ Test Locations the Density& I I I Penetrometer readings indicate the 109.0 ...... Degree of Compaction Meets D I Minimum Requirement y I I I I I for Staked Foundation 108.0 Respectfully Sub 8 9 10 11 12 13 14 fit, Moisture-%of Dry Weight e��� ��• ;� Disclaimer: Contractor is responsible to maintain �' e0 '• ` the tested area in the condition that KSM completed the indicated passed compaction test. 4 KSM is not responsible if the tested area has been altered from the approved inspected condition. P E`� V.P.o NA1696%ring PE#81439 5/15/2020 Email to: St Lucie Building Department; rick.johnson@adamshomes.com Proudly Serving Florida since 1990