Loading...
HomeMy WebLinkAboutEngineeringMETRO DADE COUNTY T „s-01KALM ���� FLORIDA CERTIFICATE of NOA#� 20-0408.01 AUTHORrzaTION # 29.976 SLTRP.4S.V1? G FZPECTATIUNS R00F WIND PRESSURE & .ATTAC;HMENT DESIGN CLIENT: INFINITY ROOFING, INC. PROJECT NAME: FPL-PRIMAVISTA-SUB-STA-nON PROJECT ADDRE55: 6375 S. US HIGHWAY 1 PORT ST. LUCIE, FLORIDA34952 PROJECT DATA: SLOPE: 0 < 7 deg FLAT MEAN HEIGHT z := 15 ft WIDTH: W := 25 ft. ENCLOSURE CLASS: ENCLOSED RISK CATEGORY: III PARAPET CONTINUOUS: > 3 ft_ (NO) REGION: WIND BORNE DEBRIS REGION DESIGN WIND SPEED: V := 175 MPH EXPOSURE: C TOPO. FACTOR: H f Lh < 0.05 USE Kzt := 1.0 DIRECTIONAL FACTOR: Kd := 0.85 DESIGN CRITERIA: Wind Design perASCE 7-10 Analytical Procedure FBC-2017 DESIGN SCOPE: ROOF CLADDING ATTACHMENT Basic Combinations Sec 2.4 (Sec.2.4.1), is Wind Uplift, 0.6W Load Combination #7: 0.6W+0.6D Negleect Deadload - Use 0.6W EDGE ZONE MULTIPLIER: Trial Calculations: z•0.40 = 6 JW=2.5 Use Multiplier a := 3 ft PROJECT DATA based on information provided byTRCI. ADHERED SYSTEM VELOCITY PRESSURE qz:= 0.00256Kz-Kzt•Kd-V2 qz = 56.57 PSF DESIGN VELOCITY PRESSURE Dqz :- O.&q7 Dqz = 33.942 PSF COMPONENTS & CLADDING: EXTERNAL COE FRO ENT GCp From Figure 30.4-2A INTERNAL COEFFICIENT: GCpi From Figure 26.11 -1 Page 1 of 2 DATE: 08128/2020 TRCI#:20-144 EXPOSURE C zmin =15ft, PRESSURE COEFFICIENT 2 9.5 Kz:= 2.01� Z goo) Kz = 0.849 CALCULATE UPLIFT PRESSURES: (perASCE 7-10) (SF =2) P := Dqz-[(—(;( .) -+- (GC"pi)] FIELD P1 := Dqz.[(-1.0) + (-0.18)] _-40.051 EDGE P2 := Dqz.[(-1.8) + (-0.18)] _-67.205 CORNER P3 := Dqz.[(-2.8) + (-0.18)] =-101.147 3260 NW 23" Avenue —Suite 300E —Pompano Beach, FL 33069 —Office 954-978-9330 — Fax 954-978-9339 1ohn0turnkeyroof ccnsuiting.com METRO DADS COUNTY t�����QO� FLORIDA NOA# 20-0408.0'1 AUTHORIZATION # 9975 SURPASSIA'G EXPECTATIONS ROOF WIND PRESSURE & ATTACHMENT DESIGN Page 2 of 2 ADHERED SYSTEM DATE: 48/2812424 SYSTEM TYPE: INSULATION ADHERED TO CONCRETE, MEMBRANE TORCH APPLIED TRCi#:20-144 ROOF SYSTEM ENGINEERING DATA: Mtrrype: GAF RUBEROID MODIFIED BITUMEN ROOF SYSTEM Miami Dade County NOA: 1M919.13; SYSTEM TYPE: A(1); Pg. 9 & 10 of 14 DECK TYPE: CONCRETE, INSULATED BASE INSULATION LAYER; MIN 1,5" ENERGYGUARD POLYISO ADHERED w OLYBOND 500 ADHESIVE * TOP INSULATION LAYER: MIN 114" DENSDECK PRIME ROOF BOARD —ADHERED w OLY13OND 500ADHESIVE BASE SHEET: ONE PLY of RUBEROI D HW 25 SMOOTH TORCH APPLIED MEMBRANE: ONE PLY of RUBEROID HW PLUS GRANULE FR TORCHAPPLIED ADHESIVE: OLYBOND 500 PER BELOW SPACINGS DESIGN PRESSURE: DP := -300 PSF CONSTRUCTION TYPE RE -ROOF 'AjVy Base and Tots Layers of hsufation to Concrete Substrate Usina Oivbond 500 Adhesive applied in 3I4" to I " Wide Ribbons Spaced at 121" o c per GAF NOA Requirements DESIGN CRITERIA; DP = -300 > P 1 -40,1 psf 112 = -67.2 psf P3 = -101.1 psf ADHERE SYSTEM ONTO CONCRETE DECKAS FOLLOWS: ALL ROOFZONES: 1) ADHERE BASE INSULATION LAYER TO CONCRETE USING OLYBOND 500 AT ABOVE-11STED SPACINGS. 2) ADHERE TOP INSULATION LAYER TO CONCRETE USING OLYBOND 500 AT ABOVE -LISTED SPACINGS. 3) TORCH APPLY BASE AND MEMBRANE PLIES PER NOA REQUIREMENTS. DIMENSION OF EDGE ZONES: DP > P-3 ADHEREALL ZONES PER NOA REQUIREMENTS. 41`y�as�eett►I The Roof Code Provisions in FBC Chapter 15ApplyTo This Work. • 81 �# No 44847 8If -113 f 4s2o t • w � •� STATE OF -�441 L 01-4 3Z60 NW Z3,d Avenue ^ Suite 300E ^ Pompano - ••• �� 4� o pano Beach, FL 33069 Office 954978-9330 Fax 954 978-9� �' � �i jahn tuy*eyroofconsulti0 on) ��j N A t � t ' �r • ��1r1:i01a•