HomeMy WebLinkAboutRoof Packet CorrectionsROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF
THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE
REQUIRED DOCUMENTS AS NOTED BELOW:
Roof System
Required Sections of the
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A,B,C
4,5,6,7
Asphaltic Shingles
A,B,D
1,2,4,5,6,7
Concrete or Clay Tile
A,B,D,E
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS
128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 5.31
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Master Permit No. Process No.
Contractor's Name Infinity Roofing & Sheet Metal Inc.
Job Address 6375 S US Highway 1 Saint Lucie,FL 33477
ROOF CATEGORY
21 Low Slope ❑ Mechanically Fastened Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
ROOF TYPE
f►► New Roof 1 ( Repair 1 `T Maintenance
ROOF SYSTEM
INFORMATION
❑ Mortar/Adhesive Set Tile
❑ Wood Shingles/Shakes
M Reroofing f°'1 Recovering
Low Slope Roof Area (SF) 800 Steep Sloped Roof Area (SF) 0 Total (SF) 800
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets.
15.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section C (Low Slope Application) Surfacing: Granulated
Fill in specific roof assembly components
and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment:
(If a component is not used, identify as "NA")
System Manufacturer: GAF
Product Approval No.: 18-0919.13 Page 9- 10
Design Wind Pressures, From RAS 128 or Calculations:
Pmax1: -40.05 Pmax2: -67.20 Pmax3:-101.147
Max. Design Pressure, from the specific Product
Approval system: -3()()
Deck:
Type: Concrete Deck
Gauge/Thickness:
Slope: 118"
Anchor/Base Sheet & No. of Ply(s): N/a
Anchor/Base Sheet Fastener/Bonding Material:
N/a
Insulation Base Layer: EnergyGuard Polyiso Insulation
Base Insulation Size and Thickness: 4'a4', 1.5"
Base Insulation Fastener/Bonding Material:
Olybond 500 foam adhesive
Top Insulation Layer: Primed Densdeck roof board
Top Insulation Size and Thickness: 4'x4', 1/4"
Top Insulation Fastener/Bonding Material:
Olybond 500 foam adhesive
Base Sheet(s) & No. of Ply(s): GAF HW 25 Smooth 1 ply
Base Sheet Fastener/Bonding Material:
Torch Allied
Ply Sheet(s) & No. of Ply(s): N/a
Ply Sheet Fastener/Bonding Material:
N/a
Top Ply: GAF - Ruberiod HW plus granules FR
Top Ply Fastener/Bonding Material:
Torch Applied
Field: N/a" oc @ Lap, # Rows N/a @ N/a " oc
Perimeter: N/a " oc @ Lap, # Rows N/a @ N/a " oc
Corner: N/a " oc @ Lap, # Rows N/a (c N/a" oc
Number of Fasteners Per Insulation Board:
Field N/a Perimeter N/a Corner N/a
Illustrate Components Noted and Details as
Applicable:
Woodblocking, Gutter, Edge Termination, Stripping, Flashing,
Continuous Cleat, Cant Strip, Base Flashing, Counter -
Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit
FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 15.33