Loading...
HomeMy WebLinkAboutRoof Packet CorrectionsROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 5.31 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name Infinity Roofing & Sheet Metal Inc. Job Address 6375 S US Highway 1 Saint Lucie,FL 33477 ROOF CATEGORY 21 Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF TYPE f►► New Roof 1 ( Repair 1 `T Maintenance ROOF SYSTEM INFORMATION ❑ Mortar/Adhesive Set Tile ❑ Wood Shingles/Shakes M Reroofing f°'1 Recovering Low Slope Roof Area (SF) 800 Steep Sloped Roof Area (SF) 0 Total (SF) 800 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Surfacing: Granulated Fill in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment: (If a component is not used, identify as "NA") System Manufacturer: GAF Product Approval No.: 18-0919.13 Page 9- 10 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: -40.05 Pmax2: -67.20 Pmax3:-101.147 Max. Design Pressure, from the specific Product Approval system: -3()() Deck: Type: Concrete Deck Gauge/Thickness: Slope: 118" Anchor/Base Sheet & No. of Ply(s): N/a Anchor/Base Sheet Fastener/Bonding Material: N/a Insulation Base Layer: EnergyGuard Polyiso Insulation Base Insulation Size and Thickness: 4'a4', 1.5" Base Insulation Fastener/Bonding Material: Olybond 500 foam adhesive Top Insulation Layer: Primed Densdeck roof board Top Insulation Size and Thickness: 4'x4', 1/4" Top Insulation Fastener/Bonding Material: Olybond 500 foam adhesive Base Sheet(s) & No. of Ply(s): GAF HW 25 Smooth 1 ply Base Sheet Fastener/Bonding Material: Torch Allied Ply Sheet(s) & No. of Ply(s): N/a Ply Sheet Fastener/Bonding Material: N/a Top Ply: GAF - Ruberiod HW plus granules FR Top Ply Fastener/Bonding Material: Torch Applied Field: N/a" oc @ Lap, # Rows N/a @ N/a " oc Perimeter: N/a " oc @ Lap, # Rows N/a @ N/a " oc Corner: N/a " oc @ Lap, # Rows N/a (c N/a" oc Number of Fasteners Per Insulation Board: Field N/a Perimeter N/a Corner N/a Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 15.33