Loading...
HomeMy WebLinkAboutbuilding permitALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 09/2/2020 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Plerce FL 94982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Address: Legal Description: Residential X Property Tax ID #: 3419-510-0327 000-9 Lot No. Site Plan Name: Block No. Project Name: DONALD HERBS Setbacks Front Back: Right Side: Left Slde: LIKE FOR LIKE �,�ANGEOUT duct work infomation attched HVAC � IGasTank Electric L.J Plumbing Total Sq. Ft of Construction: Cast of Construction: $ 8550.00 Piping LJShutters ❑Windows/Doors nklers 0 Generator � Roof Roof pitch S Pt, of First Floor:,_ Utlllties:�Sewer Septic Building Fleight: Name DONALD HERBS Name: CHRIS LANCEL Address: 216 RAMIE LANE Company: SEA COAST A(C City: PTSTLUCIE State: FL Address: 3108 INDUSTRIAL 31st STREET City: FT PIERCE State: FL `Lip Code: 34952 Fax: Phone No. 772-971-1599 Zip Code: 34946 Fax: 772-448-4416 Phone No. 772-466-2400 E-Mail: Fill in fee simple Title Holder on next page ( if different E-Mall: INFO@SEACOASTAIR,COM State or County License: GMC035421 from the Owner listed above) If value of construction Is $2500 or more, a RECORDED Notice of Commencement is required. SUPLEIy1SNT�GONSTUCTION LIEN LAUt! I:N'F01�MATION DESIGNER/ENGINEER: _ Not Applicable _ MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: _ State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit, St, Lucie County makes no representation that is granting a �ermit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Assoc ation rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, In all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for I mprovements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first)nspection. ,( yop-jntend to obtain financing, consult with lender or an attorneyyJbgfore 11 Owner STATE OF FLORIDA COUNTY 0 F sr Lucie STATE OF FLORIDA COUNTY OFsrwcle The forgoing instrument was aclmowledgey{ j�efore me The forgoing instrument was aclmowledged before me this2 dayof SEPT 20 y this 2 day of SEPT 20c2L.2by CRRIS LANGEL 1 CHRIS LANGEL (Name of person acknowledging) (Name of person acknowledging ) ignature of Notary Public- State of Florida) is t ature of Notai Public- State of Plon a ) Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Produced Type of Identification Produced Commission No. G0040561 JUSTIWdaIMOPKINSCONNELLY Commission No. ccsgo � a( ., MY COMMISSIONflGG8Wii82 ,i JUSTINA . 0 (INGCONNELLY Revised 07/15/20 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTI.E MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Project Summary Job: 0 wrightsoft° Entire House ey: QUICK CALCS, INC. For: DON HERBES 216 RAMINE LANE, PORT ST. LUCIE, FL 34952 Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside do 42 OF Outsidedb 90 OF Inside db 70 OF Inside db 75 OF DesignTD 28 OF DesignTD 15 OF Daily range M Relative humidity 50 Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24241 Btuh Structure 32704 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24241 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95 Infiltration Equipme11sensibleload 31069 Stub Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4892 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Bluth Heatingg Cooling (none) Area(ft) 2347 2347 Equipment latent load 4892 Btuh Volume (ft) 18776 18776 Airchanges/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 35960 Btuh Equiv.AVF(cfm) too 50 Req. total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond 16ACX-048-230X* AHRI ref Coil CBA38MV-048-230"++TDR AHRI ref 202363552 Efficiency 100 EFF Efficiency 12.2 EER,16 SEER Heating input 7.1 kW Sensible cooling 32900 Btuh Heating output 24241 Btuh Latent cooling 14100 Btuh Temperature rise 50 OF Total cooling 47000 Btuh Actual air flow 441 ckn Actual air flow 1567 dm Airflowfactor 0.018 cfmBtuh Alrflowfactor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -i j.c- .�.rcgnesor�^ zozo-A�g-z7 os:aa:as � •�•_ •-•^--_�-�^Ri91A-SJIe®1tiversa1201919.0.07 RBU08107 Pege1 fM1.t+p....QUICI(\Ooameiis\WriglisoftFNACWERBES,UON.np CaIc=MJO RorA Boorfaces: N + wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. For: DON HERBES 216 RAMINE LANE, PORT ST. LUCIE, FL 34952 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0,334 in/100ft 441 cfm Job: Date: aY: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.334 in/100ft 1567 cfrn SupplyvBanch Detail TableI I I a ' ' Name Design (Btuh) Htg (dim) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat] Actual Ln (ft) Ftg.E4 Ln (ft) Trunk BATH c 164 2 8 0.489 4.0 Ox0 VIFx 7.2 95.0 BEDROOM c 1576 33 75 0.479 7.0 Ox0 VIFx 9.4 95.0 BEDROOM c 3287 51 157 0.365 7.0 Ox0 VIFx 22.0 115.0 st2 BEDROOM c 3299 61 158 0,345 8.0 Ox0 MFx 30.0 115.0 st1 BEDROOM4 c 2812 56 135 0,343 8.0 Ox0 MFx 30.7 115.0 sti CLST. c 218 9 10 0.334 4.0 Ox0 MFx 34.7 115.0 st1 DINING c 2314 6 111 0.374 6.0 Ox0 VFx 18,7 115.0 st2 ENCLOSEDPORCH c 5395 59 258 0,357 8.0 Ox0 VFx 25A 115.0 st2 ENCLOSEDPORCH-A c 5395 59 258 0,343 8.0 Ox0 VFx 30.9 115.0 st1 KHCHEN c 2582 3 124 0.346 7.0 0x0 VIFx 29.4 115.0 st2 LAUNDRY c 336 11 16 0.493 4.0 Ox0 UIFX 6.3 95,0 LIVING c 1640 24 79 0.349 TO Ox0 MFx 28.4 115.0 st1 LIVING -A c 1640 24 79 0.507 7.0 Ox0 VIFx 3.6 95.0 LVING-B c 1640 24 79 0.352 10 Ox0 VFx 27.0 115.0 st1 dstI c 204 9 10 0,362 4,0 Ox0 VFx 23.1 115.0 st2 asl.2 c 204 9 10 0.363 4.0 Ox 0 VIFx 1 22.7 115.0 st2 �u I Trunk Detall Tabje Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 234 719 0.334 672 14.0 0 x 0 UmlFlx st2 PeakAVF 137 670 0.346 853 12.0 0 x 0 VinlFlx eo�m;�aue values nave dea,� ma�uany ovemeda� -Fld- wrightsoft' z9zo-Aug-2709:4a:as UHvetsa1201919.0.07 RSU08101 Pagai �� ...QUICK\Docunerds\WngFAso11 HVACWERBES, DON.np CaIc=MJe Front Door faces: N RUM W11,4610nch De a�I Table 'fl Name Grille Size (in) Htg (cfm) Cl9 (cfin) TEL (ft) Design FIR Veloc (fpm) Diam (in) Hxw (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 83 337 0 0 0 0 Ox 0 MFx rb1 Ox0 30 189 0 0 0 0 Ox 0 Wx rb6 Ox0 83 337 0 0 0 0 Ox 0 MFx rb3 Ox0 53 165 0 0 0 0 Ox 0 MFx rb4 Ox0 18 20 0 0 0 0 Ox 0 MFx rb8 Ox0 44 92 0 0 0 0 Ox 0 V1Fx rb5 Ox0 59 258 0 0 0 0 Ox 0 \AFx rb7 Ox 0 70 168 0 0 0 0 Ox 0 Wx +Id- wrightsofte zozo-Aua-2�os:aaNs ��; fK+liP....QUICK\DoumeMs\WngMsofi FNACWERB[S,DON.rty CaIc=MJII FrorA Doorfaces: N Perforrned for. CON HERBES 216 RAMINE LANE PORTST. LUCIE, FL 34952 L;,uich crA�cs, ir�c. 317 ST. LUG E LANE FT, PIERCE, F L34946 Phone: 772-466-6799 QUICKCALCS@AOL.COM Scale: 1 :143 Page 1 RighlSuitcO UnNasal 2019 19.0.07 RSU08101 2020-Aug�27 09:44:37 \Wrighlsofl WAMHERBES, a