Loading...
HomeMy WebLinkAboutGrant Residence Saeled26'-10"38'-5" 33'-4"17'-9"90'-70"133'-48"90'-97"133'-68"MDP SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC123PLOT PLAN WITH ROOF PLANHOUSE PHOTOVICINITY MAPSCALE: 1/16" = 1'-0"A-00SCALE: NTSA-00A-00SCALE: NTSPLOT PLAN & VICINITY MAPPROJECT SITEPROJECT SITESPROJECT DESCRIPTION:12x345 LG NEON2: LG345N1C-V5 (345W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESEQUIPMENT SUMMARY12 LG NEON2: LG345N1C-V5 (345W) MODULES12 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSSYSTEM SIZE:4.140 kW DC STCARRAY AREA #1:147.51 SQ FT.ARRAY AREA #2:73.76 SQ FT.(E) MAIN DISTRIBUTION PANELSHEET INDEXA-00 PLOT PLAN & VICINITY MAPA-01SYMBOLS & SYSTEM DESCRIPTIONS-01ROOF PLAN & MODULESS-02STRUCTURAL ATTACHMENT DETAILSE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGDS-01-06DATA SHEETROOF #1(08) LG NEON2: LG345N1C-V5(345W) MODULES(E) STRUCTUREGOVERNING CODES:FLORIDA RESIDENTIAL CODE, 6th EDITION 2017 (FRC)FLORIDA PLUMBING CODE, 6th EDITION 2017 (FPC)FLORIDA BUILDING CODE, 6th EDITION 2017 EDITION (FBC)FLORIDA MECHANICAL CODE, 6th EDITION 2017 (FMC)NEC 2014 CODE BOOK1-STORYHOUSEEXISTINGDRIVEWAYSALERNO ROAD(E) SHEDROOF #2(04) LG NEON2: LG345N1C-V5(345W) MODULES System Description This system is a grid-tied, PV system, with PV generation consisting of 12 LGNEON2 LG345N1C-V5 (345W) MODULES with a combined STC rated dc output powerof 4140W. The modules are connected into 12 ENPHASE IQ7PLUS-72-2-USMICROINVERTERS. The inverter has electronic maximum power point tracking tomaximize energy captured by the PV modules. The inverter also has an internal groundfault detection and interruption device that is set to disconnect the array in the eventthat a ground fault that exceeds one ampere should occur. The inverter has DC and ACdisconnect integrated system and labels are provided as required by the NationalElectric CodeWhen the sun is shining, power from the PV array is fed into the inverter, whereit is converted from DC to AC. The inverter output is then used to contribute to thepower requirements of the occupancy. If PV power meets the requirements of theloads of the occupancy, any remaining PV power is sold back to the utility. When utilitypower is available, but PV power is not available, building loads are supplied by theutility.The inverter meets the requirements of IEEE 1547 and UL 1741. This means thatif it detects a loss of utility power, it will automatically disconnect from the utility.When utility voltage is restored, the inverter automatically reconnects to the utility gridafter verifying utility voltage and frequency stability.On a day with average Florida sunshine, this system outputs 17.51 kWh per dayon site.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........DC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBDCDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberAC Alternating CurrentAPPROXApproximateAWGAmerican Wire GaugeCBCombiner BoxDCDirect CurrentDCDDirect Current DisconnectDISCDisconnect(E)ExistingEL ElevationEQEqualJBJunction BoxMCB Main Combiner BoxMFRManufacturerMINMinimumMISCMiscellaneous(N)NewOCPDOverCurrent Protection DevicePOCCPoint Of Common CouplingPVPhotovoltaicSFSquarefoot/feetSTCStandard Test ConditionsTBD To Be DeterminedTYPTypicalVIFVerify In FieldWPWeather ProofSYMBOLS & DESCRIPTIONSHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSymbols:Abbreviations:SYSTEM ACDPVMCB MDPUM 32'-7"28'-4"SDSHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1ROOF PLAN & MODULESS-01SCALE: 1/8" = 1'-0"LEGEND- SOLADECKSDPMMDPACD- AC DISCONNECT- PRODUCTION METER- MAIN DISTRIBUTION PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- TRUSSES- CONDUITROOF PLAN &MODULES- COMBINER BOXCB- UTILITY METERUMMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 12 MODULESMODULE TYPE = LG NEON2: LG345N1C-V5 (345W) MODULESMODULE WEIGHT = 37.70 LBS / 17.1 KG.MODULE DIMENSIONS = 66.38"x 40.0" = 18.44 SFUNIT WEIGHT OF ARRAY = 2.04 PSFLG NEON2:LG345N1C-V5(345W) MODULES66.38"40.0"GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:WIND ZONE 1: 4'-0" O.C. - MAX CANTILEVER 1'-4"WIND ZONE 2: 2'-0" O.C. - MAX CANTILEVER 1'-4"WIND ZONE 3: 2'-0" O.C. - MAX CANTILEVER 1'-4"SEE SHEET S-02 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOFWITH MEAN ROOF HEIGHT IS 15 FT AND SYP 2X4 ROOF TRUSSESSPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEMRETROFIT IS 18.4 DEGREES. CONTRACTOR TO FIELD VERIFY ANDSHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS.* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS AND EQUIPMENT DEAD LOADS. *ARRAY AREA = 73.76 SQ. FT.ROOF FACE AREA = 440.98 SQ. FT.73.76 / 440.98 = 16.73 % OF ROOFFACE AREA COVERED BY ARRAYARRAY & ROOF AREACALC'S (ROOF #2)ROOF TYPE - ASPHALT SHINGLE ROOFROOF TILT - 18.4°ROOF AZIMUTH - 271°RAFTERS SIZE - 2"X4" @ 24" O.C.DESCRIPTION (ROOF #2)ARRAY AREA = 147.51 SQ. FT.ROOF FACE AREA = 353.72 SQ. FT.147.51 / 353.72 = 41.70 % OF ROOFFACE AREA COVERED BY ARRAYARRAY & ROOF AREACALC'S (ROOF #1)ROOF TYPE - ASPHALT SHINGLE ROOFROOF TILT - 18.4°ROOF AZIMUTH - 181°TRUSSES SIZE - 2"X4" @ 24" O.C.DESCRIPTION (ROOF #1)(N) PV METER (IFREQUIRED)(N) ENPHASE IQCOMBINER BOX(N) (12) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERS(E) UTILITY METER(N) AC DISCONNECT(IF REQUIRED)(36) PV ROOF ATTACHMENT@ 48" & 24" O.C.(N) SOLADECK(E) MAIN DISTRIBUTION PANEL(N) UNIRAC RAIL (TYP.)WIND ZONE 3 (TYP.)WIND ZONE 1 (TYP.)WIND ZONE 2 (TYP.)ROOF #1(08) LG NEON2: LG345N1C-V5(345W) MODULES1" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUNROOF #1TILT - 18.4°AZIM. - 181°ROOF #2TILT - 18.4°AZIM. - 271°(E) FRONT YARDSALERNO ROAD(E) BACK YARDROOF #2(04) LG NEON2: LG345N1C-V5(345W) MODULES SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSTRUCTURALATTACHMENTDETAILS2ATTACHMENT DETAIL (ENLARGED VIEW)S-02MODULE MID/END CLAMPSOLAR MODULEUNIRAC RAIL5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING(E) ROOF SHEATHINGASPHALT SHINGLE ROOFATTACHMENT DETAILS-02SCALE - 1'' = 1'-0''12" X 4" TRUSSES @ 24" O.C.FLASHLOC COMPUNIRAC RAILGROUNDING MID/END CLAMP5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING2" X 4" TRUSSES @ 24" O.C.2"X4" TRUSS SPANNER FORMISSED TRUSS SPANNER(IF REQUIRED)SCALE: 1" = 3" SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCELECTRICALLINE DIAGRAMSCALE: NTS1ELECTRICAL LINE DIAGRAMSOLAR ARRAY (4.140 kW-DC STC)(12) LG NEON2: LG345N1C-V5 (345W) MODULES(1) BRANCH OF 12 MODULESNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.Q CABLEL2L1NL2L1GN20A/2PG10AGGGG (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY](N) PV METER (IF REQUIRED)L2L1NGL2L1NG(E) MAIN DISTRIBUTIONPANEL, 150A RATED,240V.EXISTING GROUNDINGELECTRODE SYSTEMBI-DIRECTIONALUTILITY METER1-PHASE, 240VTO UTILITY GRIDL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2NL1L2N(E) MAIN BREAKER150A/2P, 240VNGGGGL2L1L2L1NNGG(N) AC DISCONNECT:240V, 60AMPNEMA 3R, UL LISTEDLOCKABLE AND NON-FUSIBLE(IF REQUIRED BY UTILITY)30A/2PGGG(3) #10 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUNENPHASE: IQ7PLUS-72-2-USMICROINVERTERSPV MODULES(N) SOLADECK600 V, NEMA 3RUL LISTED(N) JUNCTION BOX600 V, NEMA 3RUL LISTED(1) #12 AWG THWN-2 – RED(1) #12 AWG THWN-2 – BLACKECG#6 AWG THWN-2 GNDIN 1” IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT, OR EMTCONDUIT RUN"(1) 12/2 ROMEX RUN IN ATTICOR(1) #12 AWG THWN-2 – RED(1) #12 AWG THWN-2 – BLACKECG#6 AWG THWN-2 GNDIN 1” IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT, OR EMTCONDUIT RUN"GL2L1L2L1GGGINTERCONNECTION120% RULE - NEC 705.12(D)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED150A + 30A = 180ABUSS RATING x 120%150A x 120% = 180AE-01 SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCWIRINGCALCULATIONSAC CONDUCTOR AMPACITY CALCULATIONS:FROM ROOF TOP SOLADECK TO LOAD CENTERAC CONDUCTOR AMPACITY CALCULATIONS:FROM AC COMBINER BOX TO MSPELECTRICAL NOTESENPHASE IQ7PLUS-72-2-US MICROINVERTERInput Data (DC)Recommended Input Power (STC)Maximum Input DC VoltagePeak Power Tracking VoltageOperating RangeMin. / Max. Start VoltageMax DC Short Circuit CurrentOutput Data (AC)Maximum Output PowerNominal Output CurrentNominal Voltage / RangeNominal Frequency / RangeExtended Frequency / RangePower Factor at rated powerMaximum unit per 20A Branch Circuit235-440W +60V27V-45V16V-60V22V / 60V15A290W1.21A240V/211-264V60 Hz47-68 Hz1.013 (240 VAC)1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR75 DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICALCOMPONENTS ARE DESIGNED AND APPROVED USINGTHE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. FBC 107. SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)LABEL LOCATION:CONDUIT, COMBINER BOX(PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4)WARNING: PHOTOVOLTAICPOWER SOURCEWARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 690.17(E), CBDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(4))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 14.5 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(7))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(4))SOLARBREAKERLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(D)(4))SOLAR CONNECTIONLINE SIDE TAPLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C))PHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDSHUTDOWNLABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)AC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)AC DISCONNECTLABEL LOCATION:INVERTER(PER CODE: NEC 690.53)PHOTOVOLTAICSYSTEMMICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)4.140 KW SOLARDISCONNECT LOCATEDTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUTDOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGRANT RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLC2925 W. STATE ROAD 434,SUITE 111LONGWOOD, FL 32779COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS6706 SALERNO ROAD, FORT PIERCE, FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET