HomeMy WebLinkAboutone line - Grant, Linda 7.2.20JURISDICTION: REV: SHEET:OF DESC.: ADDRESS: kW solar panel system 6706 Salerno Rd. Fort Pierce, FL 34951 1 1 UTILITY:FPL St. Lucie 1 Layout Designer:….. One-LineDesigner: 4.14 DATE:7.2.20 K. Griffin J. Caballero P. Scanlin 1-Line Diagram Linda Grant 4.14KWDC 3.48KWAC (1) Branch circuit of 12 modules Inverter output current: 1.21A Max system output current: 14.52A Sch 80 PVC Meter located on the west side of the home PV equipment located on roof Visible, lockable, and Labeled AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF UTILITY METER Rapid Shutdown AC Disconnect 60A Lockable and Non-Fusible 30A CB Bi -Directional Utility Meter 1-Phase 240v NN NN #10 THWN 240V AC Sch 80 PVC Main Service Panel 150 amp rated 150 amp main breaker 240v Solar Array string of 12 modules Roof Mounted Junction Box (Soladeck model 0786-3R5) Enphase EnvoyQ monitoring device Enphase Engage Cable #12/2 THWN-2 1blk1red 240V #12/2 Romex in attic/ THWN in conduit on exterior 1blk1red1gr 240V AC Sch 80 PVC NN #10 THWN 240V AC Sch 80 PVC 12 Enphase IQ7+ Microinverters (located under each panel) #6 THWN green through out system 10A CB Outdoor mounted Photovoltaic Combiner Box (Model # IQ-AMI-240-3) 20A CB PV Module: (12 ) LG345N1C-V5 Inverter: (12 ) Enphase IQ7PLUS-72 -2-US (240v) (290va)