HomeMy WebLinkAboutone line - Grant, Linda 7.2.20JURISDICTION:
REV: SHEET:OF
DESC.:
ADDRESS:
kW solar panel system
6706 Salerno Rd. Fort Pierce, FL 34951
1 1
UTILITY:FPL
St. Lucie
1
Layout Designer:…..
One-LineDesigner:
4.14
DATE:7.2.20
K. Griffin
J. Caballero P. Scanlin
1-Line Diagram
Linda Grant
4.14KWDC 3.48KWAC
(1) Branch circuit of 12 modules
Inverter output current: 1.21A
Max system output current: 14.52A
Sch 80 PVC
Meter located on
the west side of
the home
PV equipment
located on roof
Visible, lockable, and
Labeled AC DISCONNECT
LOCATED ON
ACCESSIBLE EXTERIOR
WALL WITHIN 10 FEET
OF UTILITY METER
Rapid Shutdown
AC Disconnect 60A
Lockable and Non-Fusible
30A
CB
Bi -Directional
Utility Meter
1-Phase
240v
NN
NN
#10 THWN
240V AC
Sch 80 PVC
Main Service Panel
150 amp rated
150 amp main breaker
240v
Solar Array
string of 12
modules
Roof Mounted Junction Box
(Soladeck model 0786-3R5)
Enphase EnvoyQ
monitoring device
Enphase Engage Cable
#12/2 THWN-2
1blk1red
240V
#12/2 Romex in attic/
THWN in conduit on exterior
1blk1red1gr
240V AC
Sch 80 PVC
NN
#10 THWN
240V AC
Sch 80 PVC
12 Enphase IQ7+
Microinverters
(located under each panel)
#6 THWN green through
out system
10A
CB
Outdoor mounted
Photovoltaic Combiner Box
(Model # IQ-AMI-240-3)
20A
CB
PV Module: (12 ) LG345N1C-V5
Inverter: (12 ) Enphase IQ7PLUS-72 -2-US
(240v) (290va)