Loading...
HomeMy WebLinkAboutCompaction Test Headquarters Mailing 11345 U.S. Highway 1 ENGINEERINGPO Box 78-1377 Sebastian, FL. 32958. I TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6939 KSMengineering.net DATE TESTED: May 7, 2020 KSM JOB#: 202146-1d/DJ/ct PERMIT#: 2002-0742 NUC# 404 CONTRACTOR: Adams Homes Nuc Model: MC-1 Elite JOB LOCATION: 8105 Amalfi Circle Nuc Serial#: 31404 Lot 12, Block 2,Waterstone Ft. Pierce, Florida ITEM.TESTED: Compacted Foundation Fill TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE(P.C.F) COMPACTION 1. S.W. 0"- 12" 40+ 112.2 114.9 97.7% 2. N.W. " 111.6 it97.1% 3. Center it113.5 If98.8% 4. N.E. 110.7 96.3% 5. S.E. 112.8 98.2% Soil Description: 116.0 Brown Sand W E I I I I I I with Clay I In Place Moisture: G 115.0 - I 8.3/ H T Proctor Optimum Moisture: 114.0 - 11.0% P I I I I Proctor Max.Dry Density:P.C.F. C I I I I I 114.9 113.0 F I I I I I @ Test Locations the Density& I I I Penetrometer readings indicate the 112.0 — p I_.._.I._.._r._..y.._..rt.._... Degree of Compaction Meets R Minimum Requirement Y I I I I I for Unstaked Foundation 111.0 4— — i— — —i — —i• — T••—--- Respectfully Submitted: 8 9 10 11 12 13 14 Moisture-%of Dry Weight ,GEj' Disclaimer: Contractor is responsible to maintain "' ' �' ••'�� the tested area in the condition that KSM ; ( completed the indicated passed compaction test. t KSM is not responsible if the tested area has been 'i 1E OF .. Q altered from the approved inspected condition. rya�i�ES� RF►,Rl� V.P.of Engineering PE#81439 5/8/2020 Email to: rick.johnson@adamshomes.com Proudly Serving Florida since 1990