Loading...
HomeMy WebLinkAboutCompactio Test Ardaman Soil Nuclear Gauge client: Protect: &ASSOCiateS; Inc. Perrn_it#2003-00� Renar Development Corp. 113-15-66-5434B Report Date:4/16/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential Lots Port St.Lucle Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce,FL 460 NWConcourse Place,Unit 1 Port St.Lucie,FL 34988 Phone:772-876-0072 t Test Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp. Test# Of Date Proctor ID Method Classification % c %) (Pcf) (In) Compaction (%) Remark 274 4/10/20 20-136 A 10.5 114.0 10.1 111.2 12 98 95 Pass (Modified) 275 4/10/20 20-136 A - 10.5 114.0 9.7 109.1 12 96 95 Pass (Modified) 276 4/10/20 20-136 A 10.5 1 114.0 8.8 110.4 12 97 95 Pass • (Modified) 280 4110/20 20-136 A 10.5 114.0 10.2 109.1 12 96 95 Pass (Modified) - - L28 4/10/20 20-136 A. -- 10.5 114.0 9.0 . 110.3 12 97 95 Pass Modified 4/10120 20-136 A -- 10.5 114.0 10.9 109.6 12 96 95 Pass (Modified ilnfonttatlon. Gauge Test Location Elevation Reference Make I Model/SN/Calibrated Field Technician Footings:Footin s for 9541 Seaspray Drive,Lot 11.SE End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie Footings:Footings far 9541 Seaspray Drive,Lot 11.NE End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie Footings:Footings for 9541 Seaspray Drive,Lot 11.NW End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie 280 Building Pad Fill:House Pad for 9541 Seaspray Drive,Lot 11.SW End of House Pad -1.0 Top of Pad CPN/MC73/M340507396/ Tech,Port St.Lucie 281 Building Pad Fill:House Pad for 9541 Seaspray Drive,Lot 11.SE End of House Pad -1.0 Top of Pad CPR/MC-3/M340507396/ Tech,Port St.Lucie 282 Building Pad Fill:House Pad for 9541 SeasprayDrive,Lot 11.NE End of House Pad -1.0 Top of Pad CPN/MC-3/M340507396/ Tech,Pori St.Lucie Remarks:.: . : .:: .. :. Comments: Pass:Density Pass. Tests are"Direct Transmission"(Method A)unless probe depth is noted as 'Backscatter'.Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. mw" wArdamanSoil Nuclear Gauge client: Project: &Associates,in- Perms#2a0-- 84 Renar Development Corp. 113-15-66-5434B Report Date:4/16/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential.Lots Port St.Lucia Branch Test Method:ASTM D 6938 Stuart, Ft.34996 Fort Pierce Florida CA No.6950 460 NW Concourse Place,UNt Fort Pierce,FL PortSL Lucie,FL34988 , Phone:772-878-0072 ����111111.111►���� No:63g.41 9rq OF , This item has been digital)yy signed and sealed by Branch Manager Dan J.Zrallack,p.E.on Apr 16,2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL,REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.