HomeMy WebLinkAboutCompactio Test Ardaman Soil Nuclear Gauge client: Protect:
&ASSOCiateS; Inc. Perrn_it#2003-00� Renar Development Corp. 113-15-66-5434B
Report Date:4/16/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential Lots
Port St.Lucle Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce
Florida CA No.5950 Fort Pierce,FL
460 NWConcourse Place,Unit 1
Port St.Lucie,FL 34988
Phone:772-876-0072
t Test
Optimum Maximum In Place In Place Probe
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp.
Test# Of Date Proctor ID Method Classification % c %) (Pcf) (In) Compaction (%) Remark
274 4/10/20 20-136 A 10.5 114.0 10.1 111.2 12 98 95 Pass
(Modified)
275 4/10/20 20-136 A - 10.5 114.0 9.7 109.1 12 96 95 Pass
(Modified)
276 4/10/20 20-136 A 10.5 1 114.0 8.8 110.4 12 97 95 Pass •
(Modified)
280 4110/20 20-136 A 10.5 114.0 10.2 109.1 12 96 95 Pass
(Modified) - -
L28 4/10/20 20-136 A. -- 10.5 114.0 9.0 . 110.3 12 97 95 Pass
Modified
4/10120 20-136 A -- 10.5 114.0 10.9 109.6 12 96 95 Pass
(Modified ilnfonttatlon.
Gauge
Test Location Elevation Reference Make I Model/SN/Calibrated Field Technician
Footings:Footin s for 9541 Seaspray Drive,Lot 11.SE End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie
Footings:Footings far 9541 Seaspray Drive,Lot 11.NE End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie
Footings:Footings for 9541 Seaspray Drive,Lot 11.NW End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech,Port St.Lucie
280 Building Pad Fill:House Pad for 9541 Seaspray Drive,Lot 11.SW End of House Pad -1.0 Top of Pad CPN/MC73/M340507396/ Tech,Port St.Lucie
281 Building Pad Fill:House Pad for 9541 Seaspray Drive,Lot 11.SE End of House Pad -1.0 Top of Pad CPR/MC-3/M340507396/ Tech,Port St.Lucie
282 Building Pad Fill:House Pad for 9541 SeasprayDrive,Lot 11.NE End of House Pad -1.0 Top of Pad CPN/MC-3/M340507396/ Tech,Pori St.Lucie
Remarks:.: . : .:: ..
:. Comments:
Pass:Density Pass. Tests are"Direct Transmission"(Method A)unless probe depth is noted as
'Backscatter'.Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
mw" wArdamanSoil Nuclear Gauge client: Project:
&Associates,in- Perms#2a0-- 84 Renar Development Corp. 113-15-66-5434B
Report Date:4/16/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential.Lots
Port St.Lucia Branch Test Method:ASTM D 6938 Stuart, Ft.34996 Fort Pierce
Florida CA No.6950
460 NW Concourse Place,UNt Fort Pierce,FL
PortSL Lucie,FL34988 ,
Phone:772-878-0072
����111111.111►����
No:63g.41
9rq OF ,
This item has been digital)yy signed and sealed by Branch
Manager Dan J.Zrallack,p.E.on Apr 16,2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL,REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED