HomeMy WebLinkAboutBlower Door Test J
Planning Development Services
-" Building gs Code Regulation Division
23300 Virginia
9Ave,
�i�201
� Pierce,F1.3'S�702Fort
Phone:772-46221"G5 Fa=772-462-6R43
SLOWER DOOR TEST FORM
House 9nfiltiration Test Certification
Prscillptive and Peelormance Method
Date: `f � r� L��o Permit#: I 1 o LF— o-83
Contractor: K/ g- bl o
Job Address: g �� -� Lu � � 31f g s z.
Construction: ( amew Construction—Complete Brisdng—After Addition
House Infiltration test Results 5LC Climate Zone 2
CFM(50)= 1 1 T cs'�i7a're• '� 2 Z o
Volume 01 4 f.
ACH(50)=CFM(50)x GO/Volume= 2- Me anical Ventilcauon required less than 3-ACH
Passing results must be&ACH(50)or less (Mass ( )Fail
t-BC,Energy
the building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1,2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f),(g)or(1)or an
approved third party. A writ-Len report of the results of the test shall be signed by the party conducting the test and
provided to the code ofcial. Testing shall be pefformed at any time after creation of ail penetrations of the building
thermal envelope.
C-6C.,Residential
Where the air infiltration rate of a dwelling unit is less than Bair changes per hour when tested with a blower door at a
pressure of 0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testing Corrtnany
Company Name: Pro-Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
i hereby certify that the above House infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance "th Sec' R402 a.1.2 Climate Zone 2.
Signature: r'
Printed Name: Martin Kiein
License/Certification#: 5061633