S LOWER DOOR TEST FORM
Mortise Infiltration Test Certificatlon
Prescei tive and Performance Methad
Date: >" 'c 2�20 t�ereniL�. � 4 n� — o s3� S
Contractor: l,l/V/I 1xe ere f ogo'k e!±
Job Address: i 04 54- L-.. li 3 Lf 1 2
Construction; New Construction—Complete k ) E-Ais'dnig—Afleer Addition
House Infiltration Test:Results 5LC Climate Zone 2 1
CFM(50)= tf 2 -7 2 Test Dale: � r'r t --o 2°
Volume= 11563
/
ACH(50)=CFM(50)x Go f Volume= • 6 Mechanical Ventilation required less than 3 ACH
Passing results roust be&ACH(50)or less mass ( ) Fail
I
MC,Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour In Climate Zone 1,Z and 3 air changes per hour in Climate Zones 3 through 8. ►esting shall be conducted with a
blower door at a pressure of 0.2 inches w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed asset forth in Section 489.105 (3)(f), (g)or(i)or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FSC,Residensal
Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testina Comoar►v
Company Name: Pro-Duct Services Address: 1915 Rio Vista Drive, Ft.Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with cti n R4 2. .1.2 Climate Zone Z.
Signature:
Printed Name: Mardn Klein
License/Certification##: 5061633