Loading...
HomeMy WebLinkAboutREVISION, 2020-08-25-Underground Utilities, 9.2.20, NEED FORM6'3'5' DeepFPL Main Feed →→ 3' Deep1. Meter Model# Electric Service Item: 1. 41105-02FL - 320a – Talon Meter Can 2. DG225NRK - 400a - Eaton General duty cartridge fuse safety switch 3. DT225URK-NPS - 400a – Double Throw Transfer Switch 4. ECCVH200R - Eaton Type CCV Enclosed Circuit Breaker 5. ECCVH200R - Eaton Type CCV Enclosed Circuit Breaker 2. Fused Safety Switch 3. Double Throw Transfer Switch ON OFF Service OFF Generator 4. 200a Breaker 5. 200a Breaker Feed to House ~130' Distance Feed to Garage → ~215' Distance→→→ → Travis Haag 6789 S. Indian River Drive Fort Pierce, FL 34982 Electric Permit Revision SLC-1910 -0100 Date: 09/02/2020 Note: All runs to the Office and Main house will use the following Aluminum wire: 4/0-4/0-2/0 #4 copper ground