HomeMy WebLinkAboutHealth Department Septic Approval r.
APPLICATION #:AP1447414
STATE OF FLORIDA PERMIT #:56-SF-2006946
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:FI
' 10/09120 5
/09/2019
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
•t"�WE FEE PAID:545.00
RECEIPT #:56-PID-4194711
APPLICANT: Jason Merritt
AGENT: TNT Builders
PROPERTY ADDRESS: 6310 Arapahoe St Fort Pierce, FL 34982
LOT: 11.12,&13 BLOCK: 87
SUBDIVISION: Riverdale Yacht Club ID#: 3409-703-0081-000-3
CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION SETBACKS
[ ] [01] TANK SIZE [1] 1050.00 [2] 300.00 [ ] (271 SURFACE WATER FT
( ] [021 TANK MATERIAL Concrete [ ] [281 DITCHES FT
[ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT
[ ] [041 MULTI-CHAMBERED I=N ] [ ] [301 PUBLIC WELLS FT
[ ] [051 OUTLET FILTER Polylok PL-122 [ ] [311 IRRIGATION WELLS FT
[ ] [061 LEGEND 1. 01-011-09DC3 2. 01-011-96SC4 [ ] [321 POTABLE WATER 27 FT
[ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT
[ ] [081 LEVEL [ ] [341 PROPERTY LINES 12 FT
[ ] [09) DEPTH TO LID [ ] [351 OTHER FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ ] [101 AREA [1] 672 [21 SQFT [ ] [361 DRAINFIELD COVER
( ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS
[ ] [121 NUMBER OF DRAINLINES 1. 8.00 2. [ ] (381 SLOPES
[ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 05/04/2020
[ ] [141 DRAINLINE SLOPE
[ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION
[ ] [161 ELEVATION [ AHOVE / BELOW ]BM 3.00 [ ] [401 UNOBSTRUCTED AREA
[ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF
[ ] [181 DOSING PUMPS [ ] [421 ALARMS
[ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT
[ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA
[ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING
[ ] [221 FILL AMOUNT [ ] 1471 CONTRACTOR DAVID WHITESIDE(ACCUR
[ ] [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 EQ36(single c
[ ] [241 EXCAVATION DEPTH ABANDONMENT
[ ] [251 AREA REPLACED [ ] [491 TANK PUMPED
[ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED 6 FILLED
Comments: Comments are on page 2.
CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 03/23/2020
DISAPPROVED ]° EnvironrFoAlal Specialist ria gram(ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APpROVED / DISAPPROVED ]: St. Lucie CHD DATE: 05/04/2020
Environmental Speciallst II ian J Ingram(ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used) '
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1447414 EID2006946
APPLICATION #:AP1447414
STATE OF FLORIDA PERMIT #:56-SF-2006946
DEPARTMENT OF HEALTH DOCUMENT #:FI 1403095
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 10/09/2019
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
wo FEE PAID:545.00
RECEIPT #:56-PID-4194711
Violation Number Comment
Comments
The system is sized for 4 bedrooms with a maximum occupancy-of 8 persons(2 per bedroom),for a total estimated flow of 400
gpd•
New ST,filter,DT,liberty 1/3 hp pump,and 8x7 long DF installed. No violation,system ok to cover. Contractor notified by phone.
Needs final inspection for mound system,gutters,alarm check,and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Dalabase v 1.0.1 AP1447414 EID2006946