HomeMy WebLinkAboutProject Information a • • E „ DEL=AIR b HEATING o AIR CONDITIONING January, 27 2020 ATTN: St. Lucie County,FL Dept. of Building& Code Regulation Division RE: Phoenix Homes Realty Inc. -Lot 3 Tarpon Flats The mechanical ventilation calculations as required by 2017 FBC Mechanical, 6"'Edition Chapter 401.2 for Lot 31 Tarpon Flats are designed per code and shall follow these parameters as described as proposed in the 2017 FBC-Energy Conservation, 6th Edition Chapter 4,not to exceed .01 x CFA+7.5 x(Number of Bedrooms+1): Living Square Footage: 1976 Number of Bedrooms: 3 +1 =4 .01 x 1976= 19.76 4x7.5 =30 19.76+30=49.76 CFM This method is also within compliance with the simplified 2017 FBC M1507.3.3(1) Chart as listed below: DWELLING UNIT NUMBER OF BEDROOMS FLOORAREA 0-12-34-56-7 > 7 (square feet) airflow in CFM < 1,.5C10 30 46 50 .75 90 1.501 -3,000 45 60 75 90 105 3,001 -4,t-500 60 75 90 1 G6 120 4,K1 -6,000 75 90 ID5 120 135 6,001 -7,500 90 105 120 136 150 7.5 00 106 120 135 150 165 Del-Air designed and installed a 6" diameter fresh air ventilation intake including mechanical damper, control, and shut off to handle code mechanical ventilation requirement, when a residential building's envelope tests below 3ACH50. Sincerely, Corporate Headquarters 531 Codisco Way Sanford,Florida 32771 Statewide(888)831-COOL(2665). Fax(407)333-3853 w,,vw.Delair.com State Lic.CAC032448