Loading...
HomeMy WebLinkAboutEngineeringGeneral Compressed Air Notes 1 – All work shall conform with the 6th edition of the 2017 Florida Building Code, NFPA, NEC and all other applicable federal, state and local regulations and ordinances. Furnish all labor, materials and equipment required for the completion of the compressed air systems described herein and shown on the drawings. 2 – Contractor shall secure and pay all permits, fees, taxes, inspections, tests, performance bonds, fines and all other items as required for the installation of the complete compressed air systems, and shall be responsible for obtaining his own permit. 3 – Contractor shall provide all required insurance for protection against public liability and property damage for the duration of work. 4 – Except where longer warranties are specified for specific equipment, contractor shall warrant all work to be free of defects in workmanship and materials for a period of one year after final written acceptance of the project by the owner. 5 – Provide all necessary instructions to the owner in the operation of the compressed air system before final acceptance. 6 – Provide one set of bound and labeled equipment maintenance and instruction manuals. 7 – Submit shop drawings for all materials and equipment for acceptance of owner before proceeding with the purchase or installation of any equipment and materials, as requested by owner. 8 – Ensure all equipment is labeled and identified by manufacturer, submit identification information to the owner. 9 – Products and materials specified by trade name and / or model on the drawings establish a standard of quality, appearance, performance and dimensions. Contractor shall base his bid on those items, which shall be considered to establish a standard basis of bidding. Requests for substitution shall be submitted in writing to the architect / engineer demonstrating that proposed product is comparable, and that the basic design, construction standards, quality and warranties are equal or better than the product specified. Contractor shall be responsible for any change in the work required by other trades and shall pay for any expenses incurred due to the contractor’s request for revisions or substitutions. 10 – Contractor shall maintain a set of drawings at the project site with up to date information on as-built conditions indicating with colored pens all changes and deviations from contract drawings. This sett of prints shall be turned over to the owner at the completion of the project as a pre-requisite for final payment. 11 – Provide all new materials. Provide supplemental material not specifically noted herein, but required to complete the installation in accordance with the intent of the contract drawings, at no additional cost to the owner. 12 – All work shall be field checked before installation and coordinated with all other trades. The contract drawings are diagrammatic and intended to depict approximate equipment locations and arrangements, not show any minor detail. Plans shall not be scaled: Refer to the drawings for dimensions. 13 – Offset piping as required to clear building structure, ductowrk, etc. as shown on drawings and as required by field coordination. 14 – Compressed Air Contractor shall verify all space conditions and dimensions at job site prior to fabrication and installation of materials and equipment. Verify all voltages with the owner prior to ordering any equipment. 15 – Furnish and install compressed air fixtures as specified on drawings. 16 – Provide compressed air piping as follows: A – Compressed air piping Header Piping – Header piping can be aluminum, galvanized iron, or black iron as specified by contract drawings, or as agreed to with owner. Supply Side (compressor) Piping – Supply side piping can be Aluminum, galvanized iron, black iron or stainless steel as specified by contract drawings, or as agreed to with the owner. Flexible connections can be made with stainless steel flexible hoses, or rubber hoses and applicable hose barbs. B – Condensate drains Condensate drain piping can be aluminum, galvanized iron, black iron, PVC, or poly tubing as specified by contract drawings, or as agreed to with the owner. 17 – Valves A – Smaller than 3"; Brass body, full port, blowout-proof stem, class 150 or better, or as provided by aluminum pipe manufacturer, working pressure of 200psi or greater. B - 3" and larger – flanged ends, iron body, bronze or stainless steel trim, class 150 or better, or as provided by aluminum pipe manufacturer, working pressure of 200psi or greater. 18 – Hang piping from structure utilizing galvanized hangers rods and trapeze or clevis / loop hangers. For copper piping, rods and hangers shall be copper clad. Pipe hangers provided by aluminum pipe manufacture will be used in place of clevis / loop hangers for aluminum pipe. 19 – Attach piping to walls of structure utilizing unistrut or equivalent and EMT style clamps. Pipe hangers provided by aluminum pipe manufacturer may be attached to unistrut or directly to structure. 20 – Compressed air piping test: Subject the entire system to a pneumatic test pressure of no less than 150 psi for a period of two hours without loss in pressure. 21 – Test all equipment to demonstrate proper functioning and capacity. 22 – Provide shock absorbers, dielectric fittings, hangers and inserts, trap re - sealers, vacuum breakers, gauge and thermometers, strainers, valves, etc., for complete and operable compressed air systems as required by code and as indicated on plans. Provide unions and flanges at connections to equipment for easy maintenance and dismantling. PLUMBING SYMBOL LEGEND Symbol Description Condensate Drain Vacuum Compressed Air Ball Valve Butterfly Valve Pressure Reducing Valve Safety Valve Powered Valve Flexible Hose Connect to Existing Drop “A” Drop “B” Drop “C” Drop “D” CA VA CD A B C D Compressed Air System – General Notes Pursuit Boats 3891 Saint Lucie Blvd. Fort Pierce, FL 34946 SIZE FSCM NO DWG NO REV NTS SCALE Not To Scale SHEET 3 Compressed Air System – General Notes Pursuit Boats 3891 Saint Lucie Blvd. Fort Pierce, FL 34946 SIZE FSCM NO DWG NO REV NTS SCALE Not To Scale SHEET 3 Air Compressor Works, Inc. 1956 W. 9th St. Riviera Beach, FL 33404 Compressed Air System – General Notes Pursuit Boats 3891 Saint Lucie Blvd. Fort Pierce, FL 34946 SIZE FSCM NO DWG NO REV NTS SCALE Not To Scale SHEET 3 Air Compressor Works, Inc. 1956 W. 9th St. Riviera Beach, FL 33404