Loading...
HomeMy WebLinkAboutCompaction Test MILD Mailing Xi Box 78 Headquarters E 11345 U.S. Highway 1 PO B -1377 Sebastian, FL. 32978 Sebastian, FL. 32958 r Ti I -s) Lor I, t' iN,, 'l if i�,r�1 S Orlando Phone: 772-589-0712 723 Progress Way SOR.COMPA;".1101\1 111:130*RT C.A.#5693 Sanford, FL. 32771 As','wl D 1557;:�mi;1ASTIV! 1)6938 KSMengineering.net DATE TESTED: April-14, 2020 KSM JOB#: 201748-1d/CH/ct PERMIT#: 2002-0315 NUC# 417 CONTRACTOR: Wynne Developry%jent Corp. Nuc Model: 3500 JOB LOCATION: 5 Peru Nuc Serial#: 3417 Spanish Lakes Country Club Vill,-11--E� Fort Pierce, Florida ITEM TESTED: compacted Foundation Fill TEST LOCATION PEN U Ir i V MAX. DRY PERCENT OF SAMPLE DEPTH READ PROCTOR VALUE(P.C.F) COMPACTION 1. N.E. Off- 1211 50+ 1103, .112.7 97.9% 2. S.E. 97.5% 3. Center 97.0% 4. N.W. 1.U').l 97.7% 5 S.W. 11A).5 98.0% Soil Description: Dark Brown Sand WE with Some Clay . . In Place Moisture: G ... .......... 10.8% H.. T Proctor Optimum Moisture: A 11.0% P Proctor Max. Dry Density: P.C.F. C 112.7 F @ Test Locations the Density& Penetrometer readings indicate the Degree of Compaction Meets D R Minimum Required y for Staked Foundation 109.0 Respectfully Submitted: 8 9 10 11 12 13 14 Moisture-% of Dry Weight 11isclairner: Contractor is responsible to maintain I 0�! te�,ted area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been 21t,�red from the approved inspected condition. S TA TEL 0 F ;7 Ad. PE#656 4/15/2020 mail to: clotty@wynnebc.com; St. LuCIE! County,Building Departmen't Proudly Serving, larida since 1990