HomeMy WebLinkAboutCompaction Test o?002 - 0'3 7/
Soil Nuclear Gauge Client: Project:
Report Date: 5/4/2020 Cole Construction 17-6100.00
i'�RNATON" Test Method:ASTM D 6938 497 S Brocksmith Road Cole Construction Master Agreement
Port St.Lucie Fort Pierce, FL 34954 Various Locations
FSPE CA#4930 FL
607 NW Commodity Cove
Port St.Lucie,FL 34986
Phone:772-924-3575 1 Fax:772-924-3580 _
Test Results
Optimum Maximum In Place In Place Probe Min/Max
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp.
Test# Of Date Proctor ID Method Classification N (pcf) N (pcf) (in) Compaction N Remark
16 4/28/20 P-1 N/A 12.8 103.5 11.4 102.5 12 99 95/105 Pass
• Test Information
Gauge
Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician
1
16 Below Slab Grade:3101 Matthews Rd,Ft Pierce,Back patio,Center 1 0-1 Troxler/3430/24566/ Hayes,Sean
Remarks I Comments
Pass:Tests results comply With specifications Tests are"Direct Transmission"(Method A)unless probe depth is noted as
"Backscatter".Gauge calibration data on file with the testing agency.
!.d 1 i.ate'.
(1j1 75
�� �
MAC{ zbN1
v it'd
1'�
� St" 4.f;t�'�`� �'-�►�1��yr, �'L
JINN
\ V\GENS,c'
No 63 8
65/0412020
i� Kent,16.E.
PtA siona ibi er.9
Stfdri�tl�RID
!ONA�E\\��
Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.