Loading...
HomeMy WebLinkAboutCompaction Test Headquarters � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 XNAmPAYL D ��I QqSebastian, FL. 32978 Orlando G Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL._ 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: April 16,2020 KSM JOB#: 201735-2d/CH/ct PERMIT#: , —p 0?> — (��j �— NUC# 417 CONTRACTOR: South Florida Aluminum Products Nuc Model: 3500 JOB LOCATION: 5404 Pinetree Street Nuc"Serial M 3417 Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill for the Addition-Retest TEST LOCATION PEN DRY MAX.DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE(P.C.F) COMPACTION, 1. South 0"-12" 45 108.1 110.0 98.3% 2. Center " . 40 107.2 97.5% 3. North 40 107.5 97.7% - Soil Description: 1110 T I w I 1 I 1 Brown Sand E I 1 I I ( 1 In Place Moisture: G 110.0 r —j — t --j-•—••'� 8.8% H TD Proctor Optimum Moisture: R I I I I 12.0% P Y09.0 I--••-:1 — +..—.j—..�.. �.. Proctor Max.Dry Density:P.C.F. C I I I I I I 110.0 I I I I I F 108.0 4—.._ —..�-.—:I—..�..—..�..—. @ Test Locations the Density& Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement 107.0 �-- —� — -� — �-••� `••� —, 9 for Staked Foundation w 10 11 12 13 14 15 Respeoull*'Sub . Moisture-%of Dry Weight �•1 NSF't Disclaimer: Contractor is.responsible to maintain " 439 rL the tested area in the condition that KSM completed the indicated Lpassed compaction test. LSAT- of l` KSM is not responsible if the tested area has been •.FLORto •c►�,' altered from the approved inspected condition. W ` Bryan Ymahrkwp%l . V.P.of Engineering PE#,81439 4/17/2020 Email to: sfapbooks@soflalum.com . Proudly Serving Florida since 1990 Headquarters 1 � Mang "l/� • 11345 U.S. Highway 1 1 ENGINEERING PO Box78-1377 Sebastian, FL. 32958 �Z ,AV A N D TESTI N G Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 KSMengineering.net ASTM D 1557 and ASTM D 6938 DATE TESTED: April 16,2020 KSM JOB#: 201735-2d/CH/ct PERMIT#: Z•p 0; — D3 U+ NUC# 417 CONTRACTOR: South Florida Aluminum Products Nuc Model: 3500 JOB LOCATION: 5404 Pinetree Street Nuc Serial#: 3417 Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill for the Addition-Retest TEST LOCATION DEPTH PEN DRY MAX.DRY PERCENT OF SAMPLE READ pENSITY PROCTOR VALUE(P.C.F) COMPACTION 1. South 0"-12" 45 108.1 110.0 98.3% 2. Center " 40 107.2 97.5% 3. North- 40 107.5 97.7`Yo Soil Description: 111.0 T I l I I I Brown Sand E E I I I I In Place Moisture: G 110.0 —j — t •— ••—••�,:•— 8.8% H I 1 l I T D Proctor Optimum Moisture: R I I I I 12.0% P Y09.0 {-- —1 — -1-. —.�—..�. j_..— Proctor Max.Dry Density:P.C.F. C I I I I I I 110.0 F 108.0 a—..— —..�..—.I—..�..—..I ..— @ Test'Locations the Density.& Penetrometer readings indicate the I I I I ( I Degree of Compaction Meets 107.0 — —• -� — Minimum Requirement 9 10 11 12 13 14 15 for Staked Foundation Re`pe f&l1VSiEb �,!. Moisture-%of Dry Weight 0000 NSF'•�� f Disclaimer: Contractor is responsible to maintain 439 the tested area in the condition that KSM ul" completed the indicated passed compaction test. aIF W z KSM is not responsible if the tested area has been SSA•te p FLp¢�Q ._ �`� altered from the approved inspected condition. Bryan IiI'Dahlka0p . V.P.of Engineering PE#81439 4/17/2020 Email to: sfapbooks@soflalum.com Proudly Serving Florida since 1990 Headquarters , ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 �,% 4VL AND TESTING Sebastian, FL. 32978 Orlando Phone; 772-589-07120712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771. KSMengineering.net ASTM D 1557 and ASTM D 6938 DATE TESTED: Apr!1 16,2020 d KSM JOB#: 201735-2d/CH/ct PERMIT#: 20 0 NUC# 417 CONTRACTOR: South Florida Aluminum Products Nuc Model: 3500 JOB LOCATION: 5404 Pinetree Street Nuc Serial#: 3417 Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill for the Addition-Retest TEST LOCATION PEN DRY MAX.DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE(P.C.F) COMPACTION 1. South 0"-12" 45 108.1 110.0 98.3% 2. Center " 40 107.2 97.5% 3. North 40 107.5 97.7% Soil Description: 111.0 T I I I Brown Sand E E I I I I I I I I I I f l In Place Moisture: G 110.0 —j — -j- —j-•—• j a•si T D I ! 1 I Proctor Optimum Moisture: R I I' L� 12.0% P Y09.01I ---- Proctor Max.Dry Density:P.C.F. C — II110.0F 108.0jI--..J�II ... _.....— @ Test Locations the Density& I I I I Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement 107.0 �- —� — �- — -••�••—••� —, 9 10 11 12 13 14 15 for Staked Foundation Re`p`fet¢oll 15W . Moisture-%of Dry Weight NSF"<� Disclaimer: Contractor is responsible to maintain 4,39 the tested area in the condition 'that KSM Wcompleted the indicated passed compaction test. pF KSM is not responsible onsible if the tested area has been •F�•fit oR�pe .• altered from the approved inspected condition. lom Bryan�'�OahlkeAf�!1?. V.P.of Engineering PE#81439 . 4/17/2020 Email to: sfapbooks@soflalum.com Proudly Serving Florida since 1990