HomeMy WebLinkAboutWind Load Calculation Planning&Development Services Department
® Building&Code Regulations,Division
2300 Virginia Avenue,Fort Pierce,FL 34982—(772)462-1553
Kom
Certification for Design Load Compliance
Project Name: Vista St Lucie
Project Address: 28 Lake Vista Trail, Port St. Lucie. Florida 34952
Permit#: 4004-001-1 Occupancy Type.Residential Construction Type:Re-Roof
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o , Residential Addition
o Any accessory structure requiring a building permit
o 'Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: .(complete all that apply)
1. DESIGN CODE: Florida Existing Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as(check one): X " Enclosed _Partially Enclosed Open
3. Risk Category: IX II _III IV Exposure Category:X B C D
4. Design Wind Velocity.160 mph ASD x LRFD End Zone Width: ft
5. Mean Roof Height 25 ft Roof Pitch:4 :12 Parapet:N/A ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
Zone 1:18.71-38.2 Zone 2:21.1/-59.7 Zone 3:26.5/-108.5 Zone 4:N/A Zone 5:N/A Garage: N/A
7. Design,Loads: Floor:N/A PSF Roof/Dead:15 PSF Roof/Live:20 Balcony:Nl/A PSF
Dock:N/A PSF Deck:N/A PSF Stairs:N/A PSF Fence:N/A PSF Railings:N/A PSF
8. Were Shear Walls Considered For Structure?)( Yes Not Applicable Explain Why Not: .
9. Is A Continuous Load Path Provided?X. Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:N/A-Existing PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans &specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. ['also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Javier Cisneros, P.E.
Print Name Cert#&Co.Cert Auth.
70844
Sign ture,Da ,and Seal 4C Engineering, 5903 Spruce Drive, FTP,34982
Company Name'&Address
Revised(12107/2201B