Loading...
HomeMy WebLinkAboutLoad CalcsHARDIN ADD-RENOV HVAC Load Calculations for HARDIN ADD-RENOV 12358 HARBOUR RIDGE BLVD, Unit 3-7 PALM CITY, FLORIDA 34990 SHGC WARNING: The window performance values consist of the u-factor for the frame, and Solar Heat Gain Coefficient (SHGC) for the glass. These values have a huge impact on the building thermal envelop and may have a significant impact on the following: ■ the size of the HVAC system(s), $$$ • the duct work layout and design, $$ • delays with permitting, $$$$ • inspector comments or failed inspections $$ It is important to us that your project stay on schedule and if there are any changes to the design base it may impact any of the bullet points above. KO Energy Design must be contacted immediately at info aftenergydesign.com or (561) 327-7272 to help support any changes to your project information. r MAR 17 2020 ST, Lucie County, permitting Prepared By: Karen Oliver KO Energy Design 1470 N Congress Ave, Suite 106A West Palm Beach, Florida 33409 561 327-7272 Wednesday, March 11, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ,Rhvac - Residential & Light;Conimercial HVAC toads Elite Software Development, Inc., KO Energy-Desiqn LLC NARDIN ADD-RENOV West Palm Beach, FL 33411 Page 2 Project Report `Genera' I' 7 '"&I-lfOfrTlatiOn .. Project Title: HARDIN ADD-RENOV Designed By: Karen Oliver Project Date: Wednesday, March 11, 2020 Client Name: HARDIN ADD-RENOV Client Address: 12358 HARBOUR RIDGE BLVD, Unit 3-7 Client City: PALM CITY, FLORIDA 34990 Company Name: KO Energy Design Company Representative: Karen Oliver Company Address: 1470 N Congress Ave, Suite 106A Company City: West Palm Beach, Florida 33409 Company Phone: 561 327-7272 Company E-Mail Address: info@koenergydesign.com Company Website: www.koenergydesign.com Permit Number(s): JURISDICTION: 531000 - SAINT LUCIE CO FACES: S Reference City: Fort Pierce, Florida Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb germ $el.Hum Dry Bub Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 55% 75 55 3:: . f t'.r •k:.r t 'rat! r ' a`,G,t.q 1`.'r i. 4a,a•i£ iyS �.PJ Total Building Supply CFM: 968 CFM Per Square ft.: 0.497 Square ft. of Room Area: 1,949 Square ft. Per Ton: 856 Volume (ft'): 15,836 Biaildin Loads k . w; t saJ;U'A zf fk,`:.. .' Total Heating Required Including Ventilation Air: 34,680 Btuh 34.680 MBH Total Sensible Gain: 22,032 Btuh 81 % Total Latent Gain: 5,297 Btuh 19 % Total Cooling Required Including Ventilation Air: 27,329 Btuh 2.28 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM Rhvae -,Residential & Light Commercial HVAC Loads Elite Software Development, Ina: KO. En4ov•Design LLC HARDIN ADD-RENOV West PaIrriB h: FL, 411 P Miscellaneous Report System 1 ainsOdoorstem`#Outdoor, Outdoor ;Indoor, ,.Grains .. .j ' ' In ut Data'Sy` D Bulb BulbDifference Wet Bu b ReHum ReuD Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 55% 75 54.51 Duct Sizing Inputs Main Trunk Calculate: Yes Runouts Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.00300 Pressure Drop: 0.1200 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 0 ft./min 0 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data - Winter Summer Infiltration Specified: 0.670 AC/hr 0.360 AC/hr 177 CFM 95 CFM Infiltration Actual: 0.670 AC/hr 0.360 AC/hr Above Grade Volume: X 15,836 Cu.ft. X 15,836 Cu.ft. 10,610 Cu.ft./hr X 0.0167 5,701 Cu.ft./hr X 0.0167 Total Building Infiltration: 177 CFM 95 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 37.04 = (0.68 X 0.999 X 54.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.670 AC/hr (177 CFM), Construction: Semi -Loose Summer Infiltration Specified: 0.360 AC/hr (95 CFM), Construction: Semi -Loose Duct Load Factor Sce arios for System 1 :.:Attic ` Duct Duct `_' Surface . From No. Type Descri tion Location ' Ceilin" Leaks a `'` Insulation Area MMDD 1 Supply Main Attic 16E 0.12 6 526 No 1 Return Main Attic 16E 0.24 6 98 No C:\ ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM •.• Scope Buildinci Svstem 1 Supply Duct Latent Return Duct Zone 1 1-Existing Home 2-Enclosure 2.28 856 1,949 22,032 5,297 27,329 34,680 444 968' 968 2.28 856 _1,949 221032 5,297 27,329 34,680 444I 968 1_,073 1,073 757 704' 1,461 506 1,949 21,275 3,519 24,794 444, 968 1,752 17,415 3,027 20,442 _34,174 26,593 346-M 792 197 3,860 492 4,352 7,581 99' 176 0 1 CA ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM P "• t- Y's`�.' Rh Residential & LlgFt;Commerc�al HYAC Loads s ElrtelSoftuvare Development Inc Energy HARDIN ADD RENON � KO •xy a' W.� 'ti is 4 3 a fi� m � R 4 z •.. st ..✓r.r Duct Size Preview Room or Minimu Source Maximu Rough Desig SP Duc Duc Htg Clg Act. Duct Duct Name Veloci Veloci Facto L/10 Loss Veloci LengtFlow Size Svstem 1 Supply Runouts Zone 1 1-Existing Home Built -In 0 0. 0.003 0.1, 567.5 346101 792 4-8 2-Enclosure Built -In 01 0 0.003 0.1 503.1 96M 176 1-8 Other Ducts in System 1 - - Supply Main Trunk Built -In 0 0 0.003 0.12 905.5 444 96 968' 14 Summary Svstem 1 Heatinq_Flow: 444 Coolinq Flow: 968 CA ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM Rhvac - Residential & L•ight Commercial HVAC Loads Elite Software Development; lnc: KO Ene'tgv Desiqn LLC HARDIN ADD-RENOV West Pam h F` 33411 Page FT-otarBuilding Summaty Loads Com onent r a A eSen Laf SA n..•, a e�Total F, 'Descn tion( � Gain. �` . �. _:Gam....,.. ���Gam HR771OA: Glazing-PGT HR771OA ALUM, LAM, GRAY, 58.2 1,694 0 1,472 1,472 U-value 1.04, SHGC 0.46 tmf1: Glazing -SINGLE PANE, TINT, METAL FRAME, U- 47.5 1,343 0 2,873 2,873 value 1.01, SHGC 0.48 tmf1: Glazing -SINGLE PANE, TINT, METAL FRAME, U- 40 1,131 0 1,010 1,010 value 1.01, SHGC 0.48 SGD770: Glazing-SGD770, Low E Shield Max, Clear, 120.6 3,750 0 2,695 2,695 Alum, U-value 1.11, SHGC 0.27 11 N: Door -Metal - Polystyrene Core, U-value 0.35 20 196 0 182 182 13A-3ocs: Wall -Block, board insulation only, R-3 board 843.2 3,942 0 2,154 2,154 insulation, open core, siding finish, U-value 0.167 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 135.2 345 0 265 265 cavity, no board insulation, siding finish, wood studs, U-value 0.091 13A-4ocs: Wall -Block, board insulation only, R-4 board 65.5 262 0 143 143 insulation, open core, siding finish, U-value 0.143 16E-30: Roof/Ceiling-Under Attic with Insulation on Attic 1949 1,747 0 1,560 1,560 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Light Tile, Slate or Concrete, R-30 insulation, U-value 0.032 22A-ph-c: Floor -Slab on grade, No edge insulation, no 164 6,236 0 0 0 insulation below floor, carpet covering, passive, heavy moist soil U-value 1.358 -- Subtotals for structure: 20,646 0 12,354 12,354 People: 0 0 0 0 Equipment: 0 3,800 3,800 Lighting: 0 0 0 Ductwork: 8,593 1,778 4,312 6,090 Infiltration: Winter CFM: 177, Summer CFM: 95 5,441 3,519 1,566 5,085 Ventilation: Winter CFM: 0 Summer CFM: 0 0 0 0 0 Total Building Load Totals: 34,680 5,,,297 22,032 27,329 +.•�J;. �� ,. ., y • ", �e ? ,_ w A,Y +Ya, y't .$'.N Check•Fi uresR, ..W., .`-"k�*� -J >,4 �� _. �� � � �8 ��iF f'�r5 'S�, �x'� `+ h.3 s� F �., �?�, t � a� .br,r�� . Total Building Supply CFM: 968 CFM Per Square ft.: 0.497 Square ft. of Room Area: 1,949 Square ft. Per Ton: 856 Volume (ft3): 15,836 n 97 dm Loads r`: ,; ?�� � �": �,� x` �. rP Total Heating Required Including Ventilation Air: 34,680 Btuh 34.680 MBH Total Sensible Gain: 22,032 Btuh 81 % Total Latent Gain: 5,297 Btuh 19 % Total Cooling Required Including Ventilation Air: 27,329 Btuh 2.28 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc KO Energv Design LLC HARDIN ADD-RENOV West Palm Beach FL M411Page i Building Pie Chart Floor 18% Roof 5% Wall 13% Glass 23% Infiltration 16% Door 1 % Ductwork 25% Roof 6% Wall 9% Infiltration 19% Glass 29% Door 1 % o Equipment 14% Ductwork 22% GA ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM Rhvac - Residential & Light Commercial HVAC„Loads Elite Software Development, Inc. KO Energv Design LLC HARDIN ADD-RENOV,: West Palm Beach, EL 3411- P" e System 1 System #1 Summa Loads: °Com onent '' �`` Area. Sen Lat . Sen � -Totals ®escn tion�"_ �..� Quan Loss. Gain Gaim . Gain HR7710A: Glazing-PGT HR771OAALUM, LAM, GRAY, 58.2 1,694 0 1,472 1,472 U-value 1.04, SHGC 0.46 tmf1: Glazing -SINGLE PANE, TINT, METAL FRAME, U- 47.5 1,343 0 2,873 2,873 value 1.01, SHGC 0.48 tmf1: Glazing -SINGLE PANE, TINT, METAL FRAME, U- 40 1,131 0 1,010 1,010 value 1.01, SHGC 0.48 SGD770: Glazing-SGD770, Low E Shield Max, Clear, 120.6 3,750 0 2,695 2,695 Alum, U-value 1.11, SHGC 0.27 11 N: Door -Metal - Polystyrene Core, U-value 0.35 20 196 0 182 182 13A-3ocs: Wall -Block, board insulation only, R-3 board 843.2 3,942 0 2,154 2,154 insulation, open core, siding finish, U-value 0.167 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 135.2 345 0 265 265 cavity, no board insulation, siding finish, wood studs, U-value 0.091 13A-4ocs: Wall -Block, board insulation only, R-4 board 65.5 262 0 143 143 insulation, open core, siding finish, U-value 0.143 16E-30: Roof/Ceiling-Under Attic with Insulation on Attic 1949 1,747 0 1,560 1,560 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Light Tile, Slate or Concrete, R-30 insulation, U-value 0.032 22A-ph-c: Floor -Slab on grade, No edge insulation, no 164 6,236 0 0 0 insulation below floor, carpet covering, passive, heavy moist soil U-value 1.358 Subtotals for structure: 20,646 0 12,354 12,354 People: 0 0 0 0 Equipment: 0 3,800 3,800 Lighting: 0 0 0 Ductwork: 8,593 1,778 4,312 6,090 Infiltration: Winter CFM: 177, Summer CFM: 95 5,441 3,519 1,566 5,085 Ventilation: Winter CFM: 0 Summer CFM: 0 0 0 0 0 System 1 System #1 Load Totals: 34,680 5,297 22,032 27,329 `check Supply CFM: 968 CFM Per Square ft.: 0.497 Square ft. of Room Area: 1,949 Square ft. Per Ton: 856 Volume (ft3): 15,836 M�- Total Heating Required Including Ventilation Air: 34,680 Btuh 34.680 MBH Total Sensible Gain: 22,032 Btuh 81 % Total Latent Gain: 5,297 Btuh 19 % Total Cooling Required Including Ventilation Air: 27,329 Btuh 2.28 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance data at your design conditions. C:\ ... \12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM Rhvac = Residential & Light Commercial HVAC Loads Elite Software Development, Inc. KO Energv Desiqn LLC HARDIN ADD-RENOV•. West Palm Beach FL 33411 Page T S stem 1 System #1 Pie Chart Floor 18% Roof 5% Wall 13% Glass 23% Infiltration 16% Door 1 % Ductwork 25% Roof 6% Wall 9% Infiltration 19% Glass 29% Door 1 % o Equipment 14% Ductwork 22% CA ...\12358 Harbour Ridge Blvd-MJ.rh9 Wednesday, March 11, 2020, 2:32 PM KO Energy Design, LLC J!b-,ENERGY DESfGti Field Verification Requirement Project Information Project title: HARDIN ADD-RENOV Designed by: Karen Oliver Project date: Wednesday, March 11, 2020 Client name: HARDIN ADD-RENOV Client address: 12358 HARBOUR RIDGE BLVD, Unit 3-7 Client city: PALM CITY, FLORIDA 34990 Company name: KO Energy Design Company phone: 561 327-7272 561 327-7272 Field Verification Requirement All inputs/defaults/building characteristics used for the ACCA Manual J Version 8 calculations must be verified by the HVAC contractor in the field and/or must be verified by the builder/owner verifying that what is being built is consistent with the builder's/owners project components in this report. Test and balance reports if performed are to reflect Manual J system actual CFM for each individual unit. K.O. Energy Design must be notified in writing of any said changes. Equipment Selection Equipment selected below was carefully chosen to meet or exceed the FL Energy Efficiency Code. Alternate equivalent equipment selection shall also meet the attached Energy Code Requirements. Any change in SEER or size of equipment will require approval and plan revision. K.O. Energy Design must be notified in writing of any said changes. Manual D Duct Sizing Duct sizing has been carefully engineered at the stated s.p. Any deviance in duct sizing could impact the performance and efficiency of selected equipment. Any change or alteration in duct sizing will require approval and possible plan revision. K.O. Energy Design must be notified in writing of any said changes. Duct sealing Air Distribution System Test to be performed and made available for Rough Duct Inspection, if required.