HomeMy WebLinkAboutBuilding PlansGENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN& CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA BUILDING ®®® CODE (6TH EDITION), LATEST EDITIONS OF ACI 318, NCMA, NATIONAL FOREST PRODUCT ASSOC., NDS, TPI, AND — ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK. 3. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. 4" SPHERE UNABLE TO PASS THRU CABLE RAILING SYSTEM; DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE 1. RISK CATEGORY: II 2. CODE REFERENCE: 2017 FLORIDA BUILDING CODE-R (6TH EDITION) & ASCE 7-10 6" SPHERE UNABLE TO PASS THRU SITE DECKING 2017 EXISTING FLORIDA BUILDING CODE (6TH EDITION) #8 X 1 1/2" S.S. a 3. BUILDING DESIGN: PARTIALLY ENCLOSED (DECK ONLY) OR GALE. EMBED SCREWS PER N 4. MEAN ROOF HEIGHT: <=15.0' NTERSECTIOft'"" 5. GCpi: 1: 0.55 Lj 6.WIDTH OF END ZONE: A=4.0' ri 7. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST 124 MPH (Vasd) 3-SECOND GUST *USED FOR ANALYSIS* W 8. WIND EXPOSURE: C CABLE RAILING SYSTEM, 9. ADJUSTMENT FACTOR: 1.21 INSTALL PER MANUF. 10. SUPERIMPOSED LOADS: I FLOOR (DEAD) 20 PSF FLOOR (LIVE) 40 PSF ROOF (TOP CHORD DEAD) 15 PSF ROOF (TOP CHORD LIVE) 20 PSF 2 X 8 PT JOISTS @ 16" O.C. ROOF (BOT. CHORD DEAD) 5 PSF A,/ WALL 18 PSF 11. SHEAR WALLS WERE CONSIDERED M _ 1 a. - (2) 2 X 8 PT #2 SYP, BOTH SIDES OF 12, A CONTINUOUS LOAD PATH WAS PROVIDED T COLUMN, IL' (ORLY EQ.) & O TOGETHER W/ "LIQUID NAIL" (OR EQ.) &ROWS OF (3) 12d 13. COMPONENT &CLADDING DETAILED NAILS @ EA. END & 12" O.C. THROUGHOUT 14. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE CARRY BEAM ATTACHED TO POST W/ (2) 5/8" S.S. OR GALV. THRU-BOLTS @ EA. W/ 2" X 1/4"WASHERS TIMBER NOTES: O N 1. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH: N 1.1. INT. & EXT..BEARING WALLS, TOP PLATES, WINDOW BUCKS, & HEADERS: LO 1.1.1. SOUTHERN YELLOW PINE #2 OR BETTER 1.2. BOTTOM PLATES AGAINST CONCRETE: 1.2.1. PRESSURE TREATED SOUTHERN YELLOW PINE #2 OR BETTER LU2. ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. QD 3. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS SHALL BE COMMON WIRE NAILS. SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD. EXISTING SAND SET PAVERS TO REMAIN `— 2 X 12 PT SYP STRINGER @ 16" O.C. MAX./STRINGERS ATTACHED W/ SIMPSON H2.5A(OR EQ.) W/ (10) 8d NAILS @ EA. STRINGER INTERSECTION (2 X 8 CARRIER BEAMS BOLTED W/ (2) 5/8" S.S. OR GALV: THRU-BOLTS @ EA. ` W/ 2" X 1/4". WASHERS — EXISTING4 X 6 PT # SYP TREX COMPOSITE DECKING COLUMNS (TYP.) TO ATTACHED W/ (2) #8 X 1 1/2" S.S. REMAIN - ATTACHED W/` OR GALV. EMBED SCREWS PER SIMPSON PB44R W/ (12) INTERSECTION 16d NAILS @ EA. (EMBED. INTO CONC. AS SHOWN) N In LU Z Lo � N a �O N 0 W Q > ® _U 10 ca n J CD E y va 0 U) W.N I- = V1 0) N LU C N a U) c LL N N L U 7 a) a /p co N r LL N N co �0, �o 0 M W in N Z# O Q O U(o N N co co U) .� 0 aU N M N C O N o� • v "' � o re: pp ;lu , ; eo _. ........ �,- I II II II 2. X 12 STRINGERS 2 X 4 PT SYP ATTACHED II TO CONCRETE W/y" X SIMPSON 1 12.5A @ IrMENNE/A//�.��0 II I I /// 3" TAPCONS @ 16" O.C. 12 X 8 PT SYP BEAMS EACH STRINGER I II II II / SECTION THRU STAIRS .ill SCALE: 3/4' - V-0" IJ II II II �I J ,' EXISTING WOOD STUD - WALLS, II II II T -C L J MAINTAIN TWEEN POSTS. TO PAN BEG _ MINIMIZE CABLE DEFLECTION II _ _-_J I ---- 5_O,1MAX ,III u w ul � nl 1 1 X BOARDS ATTACHED TO JOISTS W/ 3 16d NAILS EA. JOISTS I CABLE RAILING SYSTEM, INSTALL PER MANUF. ' ==1 3" MAX SPACING -III 11 li EXISTING COVERED' o r OOm CAG� E �$F�v wman y$ o moo p�+cm.o�v A�'ppo R'yU 0 N W N Q d) ❑ N LL7 O LU h co fn LU - a < REMAIN: EXISTING FLOOR HANDRAILS, GUARDS & PICKETS II III I I III TRUSSES, V.I.F. •' E io MUST RESIST 200 LBS (OR 50 (q LB/FT.)(WHICHEVER. IS GREATER) _ : _ . — _ ;I I _ . _ • _ . o : �- OF LATERAL FORCE - 4 X 6 COLUMNS I LU W IIIWjJIII IIIj _= III IIIII <.UW2 X8 PT SYP JOISTS UJy @ 16" O.C. 1— U - iLIJ n) I EXISTING •— Z / ( I . _ _. _, RESIDENCE L.. \. � . . � ' TO REMAIN ; M a 2 X B PT SYP BEAMS I- III I 7 TREX COMPOSITE DECKING MI '—'—'—'IIfT ——'—'Iff—IT / 0 O Y ATTACHED W/ (2) #8 X 1 1/2" S.S. I 0 = as OR GALV. EMBED SCREWS PER 2 X 8 PT JOISTS @ 16" O.C. (2) 2 X 8 PT #2 SYP, BOTH SIDES OF — — - — • : — < a INTERSECTION ATTACHED TO BEAMS W/ SIMPSON COLUMN, FULLY LAMINATED H2.5A W/ (10) 8d NAILS (SEA. TOGETHER W/ "LIQUID NAIL" (OR EQ.) I Ill— , _ _ , — .ILLJ I OJ cn L SIDE)(TYP.) & ROWS OF (3) 12d NAILS @ EA. END . — — . I U_ U & 12" O.C. THROUGHOUT CARRY II I — . — . — . — . BEAM ATTACHED TO POST W/ (2) 5/8" I II f�I _ _ _ _ QD UJ S.S. OR GALV. THRU-BOLTS @ EA. W/ I �z.,� III .. w N 2" X 1/4" WASHERS — — — W W — EXISTING WOOD STUD Q) a: m - WALLS, V.I.F. I � o a) Ell_._.-- I =_Z� =� _.: U_ o -� II — I I -III= = ROOF NG� J Z EXISTING 4 X 6 PT # EXISTING 4 X 6 PT # EXISTING 4 X 6 PT # I) v (7 II III III I BELOW TO oW �.% U U) SYP COLUMNS (TYP.) SYP COLUMNS (TYP.) SYP COLUMNS (TYP.) I (� J N of W m TO REMAIN TO REMAIN TO REMAIN III= : _ : REMAIN ® fu o ,I..� — t II -- �O,��m OW 06 W VJ Z W CNI__ _ JI �n..t LI co wOz o II I� I Z ATTACHE A21 ANGLE II— ; _ . _ . —, . _ .IMJ .— . J IF -2 X 12 STRINGERS i1 ATTACHED W/ (2) 8d X 1 I f� I I a) W Q1/2" NAILS (EA. LEG) I �. -- ll ` I I W = � m C) m Z . Z O U L J I BOARDS ATTACHED TO V y ; U) EXISTING CONCRETE I JOISTS W/ (3) 16d NAILS EA. c A uV,) SLAB & FOOTINGS, V.I.F. EXISTING FOUNDATIONS I JOISTS V J .. TO REMAIN PROJ. NO. 20-1240 STRUCTURAL FRAMING FLAN LIATE o5/zs/zo2o SCALE:1/4":1:,_Da.NOTE: ALL DIMENSIONS TO BE �aO E O. =. VERIFIED IN FIELD ,, ..... I ®EXISTING WALL TO REMAIN S-1 SECTION THRU DECK SCALE: 3/4„=1,_0" SHEET. 1 OF 1