Loading...
HomeMy WebLinkAbout18686.1 GAF UnderlaymentFlorida Building Code Online Page 1 of 2 24-�- !fw li N; s Business & Professional Regulation SCIS Home Log rn User RegiStration Hot Topics Submit Surcharge Stars A Facts Publications Contact Us ©CIS Site Map Links Search prProduct Approval tISlR: Punic user Product AoorvyaI Menu a Product or Application Search > ApullCatlon list 7 Application Detail FL # FL18686-R3 Application Type Revision Code Version 2017 Application Status Approved "Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated by Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code GAF 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Michael Stieh mstieh@gaf.com Michael Stieh 1 Campus Drive Parsippany, NJ 07054 (973) 628-3000 mstieh@gaf.com Richard Weiman 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 RWeiman@gaf.com Roofing Underiayments Evaluation Report from a Product Evaluation Entity Miami -Dade BCCO - EVL Miami -Dade BCCb - QUA 02/22/2023 Miami -Dade BCCD - VAL Standard ASTM D226 Year 2009 https:llwww.floridabuilding.orglprlpr_app_dtl.aspx?param=vGEVXQwtDquIGtg5bCXRsc... 9/5/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option C Date Submitted 02/26/2018 Date Validated 03/1612018 Date Pending FBC Approval Date Approved 03/26/2018 Summary of Products FL # t+iodel, Number or Name Description 18686.1 FeltBuster High -Traction Synthetic Roofing Felt Limits of Use Installation Instructions Approved for use in HVHZ. Yes F L18686 R3.11 L$4114,I5,Rdf. Approved for use outside HVHS: Yes Verified By: Miami -Dade BCCO - EVL Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL18686 R3 AE 18-0119.15.odf Fick Nix! Contact tM :. 2601 glair Stone Road. Tallahassee FL 32399 Phone: 850.487.182A The State of Florida is an ANEC-0 employer. Copyright 2007.2013 State of Florida.:; Pr[yacy Statement :: Accessibint Statement :: Refund Statement Under Florida law, email afldresse5 are public records, if you do not want your e-mail Address released in response to a public -records request, do not send elearonle mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the department with an email address if they have one. The emsds provided may be used for official communlration with the bcensee. Flowerer email addresses are public record. if you do not wish to supply a personal address, please provide the Department with an ema 11 address which Can be made available to the publ lc. To determine if you are a licensee under Chapter 455, F.S., please ckk here . Ptadyot Approval Accepts: ® ® in @.:F.rcM Credit Card Sate littps://www.floridabui lding.org/prlpr_app_dtl.aspx?param---wGEVXQwtDquIGtg5 bCXRse... 91512019 MIAMM�rQE � MIAMI-DADE COUNTY PRODUCT.CONTROL SECTION DEPAW17MENT OF REGULATORY AND ECONOMIC RESO1JRC1 S (Itm) 11865 SW 26 Stred, Room 209 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 3.3175-2474 T (786) 3.15»2590.. F. (78t) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mianddade.g6yleconomy GAF I Campus. Drive Pairsipanny,. NJ 0.7054 SCOPE: I'M$ NOA is being issued under the applicablerules and regulations.governing the use:of construction. materials. The documentation submitted has been reviewed: and accepted. by Mianfi-Dade County RER - Product Control Section to be used. in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ.). This NOA shall not be valid after the expirationdate stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County.) reserve the right to have this product or material tested for quality assurance purposes. If this product -or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the. use. of such :product or material within their jurisdiction. RER reserves the right to. revoke this acceptance, if it is deterinined by Miami -Dade County Product Control Section that this product. or material fails to meet.the requirements of the applicable building code. This.product-is approved as described herein, and. has been designed to comply with the Florida Building Code including the High Velocity Hurricane. Zone of the: Florida Building Code. DESCRIPTION: GAF :Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's: name or logo, city, state.and following statement: ".Miami -Dade .County Product Control Approved"; unless otherwise noted herein. RENEWAL ofthis.NOA.shall be considered. aftera renewal application has been filed and'there has been no change in the applicable building code negatively affecting.the performance of this. product.. TERMINATION of this NOA will occur after theexpiration. date or if there has been .a revision or change. in the. materials, use,. and/or manufacture of the. product or. process..Mis.use of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure: to comply with any section of this NOA shall be for termination and removal .of NOA.: AwERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and :followed by the expiration date may be displayed. in advertising literature. If any portion of the NOA is displayed, then it shall be done .in its entirety. INSPECTION.: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available foi•,inspeeti.on atthe joh:site,at the request .ofthe Suilding.0 icial. This NOA renews and revises NOA 1`5-1213.04.and. consists.:of pages I throtigh t0. The submitted docurrientatioh was reviewed. by Hamley Pacheco, P. NOA No.: 18-0119.18 M#AMMAGE.COCENTY t Expiration Date:. 02/22/23. hw.. .Approval Date.:.U2/22/19 Page.1 of 10 ROOFING -COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS1PolypropylenelAsphalt PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification. Description WeatherWateho Mineral 36" x 50' rolls ASTM D 1:970 Granular surfaced modified, fiberglass. reinforced, Surfaced Leak Barrier 36." x 66.7' rolls bituminous sheet material for use as .a leak barrier ManufacMri.'ng underlayment in sloped roof assemblies.. Location:##]., 9. :Designed as an ice & rain shield. StormGuard")Film. 36'.x.66.7' rolls ASTM D 1910 Modified,fiberglass reinforced, bituminous sheet Surfaced Leak.Barrier material for.use as a high temperature: leak barrier Manufacturing: underlay.inent.in sloped roof. assemblies. Location #1, 9 Designed as an ice &.rain shield. LibertyTM SB.S Self- 39J/s" x 66' rolls ASTM D 1970 Self -adhering SBS roof membrane. Adhering Ease/Ply Sheet ASTM D460I Manufacturing. Type ll Location #1, 9 Deck -Armor" Premium 54" x 22T rolls ASTM D 226 A UV -stabilized polypmpylene.breathable Breathable Roof Deck 48" x 100' rolls Type II underlayment. To be used for roof deck Protection protection as an underlayment in sloped roof Manufacturing assemblies. Location ##2 Tiger PawTm Roof Deck 4.8" x..25.0' rolls A.STM. D:'226 A. OV-stabilized polypropylene. non -breathable Protection 48" .x 100' rolls Type.11 underlayment. To.be used for roof deck .protection Manufacturing as an underlayrrimt.in sloped roof assemblies. .Location #3, 5, 6 FeltBustetO Nigh -Traction . 48" x 250' rolls ASTM .D 226 A UV -stabilized polypropylene. non -breathable Synthetic Roofing Felt Type I unOrlayrrient. To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location. #7, 8 Shingle -Mateo Roof Deck 36" x 144' rolls ASTM D .226 l=ibergass-reinforced. asphalt felt underlayment. To Protection Type I be. used for roof deck protection as an Manufacturing underlayment in sloped roof assemblies. Location. #.4 NOA No.: 18-0119.15 �¢ Expiration Bate: 02/22/23 Approval Date: 02/22/18 Page 2.6f 10 PRODUCTS DESCRIPTION: Test .Product Product Dimensions Specification Description LibertyT,'4 SA Glass Cap 39 %1 ' x 34' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Sheet ASTM D 6163 self-adheringSBS roof membrane. Manufacturing AS.TM..D 7530 Location # 9 GAFGLAS® Ply 4 39.37' ASTM D2178 Aspahalt impregnated glass felt with aspahlt Manufacturing (.l meter) Wide Type IV coating: Location # 9, 14 GAFGLASO F+1emyT'z b 39.37" ASTM D2178 Aspahalt impregnated glass felt with aspahlt .Manufacturing {l meter}.Wide Type V1 coating. LOCRU64 # 9, 10 MANUFACTURING LoC.A:TIGN: 1.Mt, Vernon, IN 2.North gay, Qntario 3.Mission, British .Columbia 4..Pryor,.OK 5.Qingdao, China 6.Charleston, SC. 7.Spartantiurg, SC 8.Dadra, .India 9.Sayannah, GA. 14.Moliile, AL NON NO.: 18--0119.15 MIAMWADIECOLFtM ..; laxpiration Date: 02122123 Approval Date: 02/22/18 Page:3. of 10. EVIDENCE, SUBMITTED: Test Azency Test Identifier Test Name/Report Date Intertek Testing Services -NA Ltd. 3.077464-01 ASTM D 1970 08/23/06 .3090131 Wind Uplift and Self Sealabiiity 08/23/06 10025858:3.CO.Q-010A ASTM D,2.26 Type 11 .01108L11 100673818CO.Q-0.03 ASTM D.2.26 Type 11 061131.13 10 157289000Q-005 ASTM D.226 .Type::1I 041.1.7/14 F8549:02-106-18 ASTM D 226 Type I 11108/16. PRI Construction Materials RGM-021-02-01 ASTM D 4798 051161.07 Technologies; LLC.. GAF-112=02701 ASTM D 2.26 Type.I1. 03/15/06 GAF7238.02-01 ASTM ❑ 1970. 03/03/10 GAF-323-02=01 ASTM .D 1970. 1 I13011 I. GAF=324=02-01 ASTM D 1970. I210111 I GAF-325 02-01: ASTM D 1970 12101111 GAF-326-02-01. ASTM D 1970. 1 I130/11 GAF-275-02-01 ASTM D 1970 11 /11 /10 GAF-34.4-02_0I ASTM. D 1970 04/23/12 GAF-339-02-0I ASTM -D 226 Type I 03/1.4/12 .ELK-311-02-0.1 ASTM❑ 1970. 09/11/07 GAF-518-02-01 ASTM D 226 Type-4 06/04/14 GAF-818"02-0.1 ASTM D 4533 12106113 GAF-829-02.01 ASTM D 226: Type It 0] 115118 GAF7314-02-01 ASTM D 2.178. 0712 i 111 GAF-31.5-02701 ASTM D 21.78 07/21 /11 Trinity-ERD GAF-SG.13285.03:17-1 ASTM D 1970 03/08/1.7 GAf�-SC.13285.03..17-3 ASTM. D .1970 03/01/17 GAF -SC 13285.03.1774 ASTM D 1970 43/01 /1.7 GAF-SC13285.02:17-2 ASTM D 460.1 Type 1.1 02/08/1.7 GAF-SC9700.08-15=R] ASTM D 2178 091091I5 GAF-SC.1.29]5.1117-R] ASTM D 1970 12/1.1117 GAF -SC 12915.12.17-R1 ASTM D 6.163 1211.1117 GAF-SC12915,12.17-RI ASTM .D 7530 12/1 I117 NOA No.: 18-0110J5 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 4 of 10 APPROVED ASSEMBLIES: Deck Type 1: Woad, .non -insulated. Deck Description: 19132" or greater plywood or wood plank Systern E (l): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: Two plies of ASTM. D 226 Type I or.Shit gle-Match' Roof Deck. Protection OR one or.rnore plies of ASTM D 226 Type 11, Deck-Annor' Premium Breathable Raof Deck Protection, FeltBusteI4 High=Traction Synthetic Roafng 1^elt, or Tiger Paw""4 Roof .Deck Protection w.itli a minimum 4" side lap. and a C" end lap mechanically fastened to the. deck with -approved nails and tin caps b" ox. at the laps and four. staggered rows 12" o.o. in the lieId. of the. .rolI If.roof is exposed to rainlsnow,..tape all end and. side laps with approved butyl adhesive based seam/cover tape:or an approved waterproof cloth duct tape (follow the tape's manufacturer'.s installation instructions). Always apply tape over all fasteners at the center of the rollor the end. laps to lielp prevent rain or snow from entering at. the fastnerrem. Membrane: One.ormore plies of WeatherWatchol) Mineral Surfaced Leak Barrier, StormGuardo Film. Surfaced Leak Barrier, .Liberty-Im SA .Glass Crap Sheet, or LibertyT"11 SBS Self -Adhering Base/Ply Sheet membrane with a minitnum.3" side.1ap. and 6.' end lap. Place the first.: course.. of membrane parallet to the cave, rolling the. membrane to. obtain maximum contact. Remove the releasemembrane as the. membrane. is applied. Vertical strapping of the roof with WeatherWatch' Mineral 'Surfaced Leak Barrier; or StormGuarO Film Surfaced Leak Barrier is acceptable. Surfacing: Approved Roofing Assembly. NOA No.: 18.0.11.9.15 �MMIDAD CC1UHiY Expiration Date: 61/22/23 Approval Date: 02/22/18 Page of 10 Deck Type 1.: Wood, non -insulated Deck Description: "'62" or greater plywood or wood plank System E(2): Membrane mechanically fastened to deck.. Separator Sheet: One. or more plies:.of GA.FGLASo Ply 4, GAFGLASOF1exPlytm 6, $hingle-Mate.Roof Deck Protection, Deck -Armor" Premium Breathable Roof Deck. Protection, F`eltBuster° High - Traction Synthetic. Rooting. Felt, or'Tiger Paw' Roof Deck Protection loose laid. Membrane: One: or:more plies of W.eatherWatchP Mineral Surfaced Leak .Barrier, 5tormG.uardo Film.. Surfaced Leak Barrier, LibertyTM:SA Glass Cap Sheet, or LibertyTM SBS: Self Adhering Base/Ply Sheet membrane mechanically fastened with a minifnUrn 3":side lap and a 6" end Iap to deck through the separator sheet with approved nails and tin caps 6" o c: at the laps and two staggered.ro.ws:.12" o.c. in. the field .of the roll.. Surfacing: Approved Roofing Assembly. rsuu�s [Ou�rt r NOA No.: 184119.15 Expiration. Date: 02122123 Approval ORte: 0212211 S Page 6 of 10 Deck Type 1: Wood, non -insulated Deck Description: F.9l32" or greater plywood or wood plank System E .(3.): Anchor sleet mechanically fastened to deck, :membrane adhered. Secondary Water Install a minimum 4"w.ide WeatherWatcho Mineral Surfaced Leak Barrier, , Liberty'M SB.S Barrier: Self Adhering Sale/Ply Sheet, LibertyrM SA Glass Cap Sheet, or StormGuard' Film Surfaced (Optional) Leak.Barrier inembrane; aver the joints .of the plywood roof deck prior:to installation of the. base sheet. Do not overlap end or side joints. AIi side and end laps should be hutted firmly :side by side; flush with each other but not. overlapped: Do. riot leave the WeatherWatch'' Mineral Surfaced Leak Barrier,. or StormGuardo Film Surfaced Leak Barrier membrane exposed for more than.30 days without a roof deck protection underlayment protecting the secondary water barrier: Base Sheet: Two plies of ASTM D 226 Type or Shingle -Mate Roof Deck Protection OR one or more plies of ASTM D 226 Type 11, Deck-Annor'Fm Premium Breathable Roof -Deck Protection, FeltBuster' I-ligh-Traction. Synthetic Roofing Felt, or Tiger Paw'r,".Roof Deck Protection with a minimum 47 side lap and a 6" end lap mechanically fastened to the deck with approved nails and. tin caps.6" o.c. at the laps. and four:staggered rows 12" o.c.. in the field ofthe roll. If roof is exposed to fain/mow, tape all end -and side laps with :approved butyl adhesive based seam./cover tape or an approved waterproof cloth duct tape (follow the tape.manufactureCs installation instructions). Always apply tape over all .fasteners at the center ofthe.roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved. Roofing Assembly: NOA No.: 1&0110.15 Expiration Date: 02/22/23 Approval Date: 02/22/18 Page 7 of 10 Deck Type 1: Wood, non -insulated. Deck Description.: 19/32" or greater plywood or wood plank System E (4): Anchor sheet mechanically fastened to deck; membrane adhered. Base Sheet: Two plies ofASTM D 226 Typed or Shingle -Mate® Roof Deck Protection OR one or more plies of AST.Iv1 D 226 Type 11, Deck -Armor" Premium Breathable Roof Deck Protection, F eltBustee High -Traction Synthetic. Roofing.Felt,. or Tiger Pawl " Roof Deck Protection with a minimum 4".side .lap and a 6" end. lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof:is..expo.sed to rainlsnow, tape all.end and side laps with approved butyl adhesive based searn/cover tape or an approved waterproof cloth duct tape (follow the.tape's manufacturer's installation:instructions.): Always apply tape over all fasteners at the center or the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of 5tormGuardo Film. Surfaced Leak Barrier membrane with a ininimum 4" side.lap and. G" end::lap. Place the first course. of membrane parallel to the eave, rolling. the. membrane to -obtain maximum contact..Rerhove the release membrane as the tnernbrane is applied. Surfacing: Approved for Metal roofing; Slate; and Asphalt Shingle asseanblies. NOA .No.:: I8-6114.15 Expiration Date: 02/22/23 Approval Date: 02122118 Page 8 of 10 LIMITATIONS' I.. Fire classification is not part of this acceptance. 2. WeatherWatch' Mineral Surfaced Leak Barrier, StorniGuard' Film Surfaced Leak Barrier,. LibertyTM :SBS Self- Adhering-Base/Ply Sheet, Liberty TM SA Glass Cap Sheet, Shingle -.Mate® Roof Deck Protection, Deck-ArmoM Premiurit Breathable. Roof Deck Protection; FeitBuster' High -Traction Synthetic .Roofing Felt, and Tiger Paver"'' Roof Deck Protection shall .not be used as roof the under]ayment: 3.. This acceptance is for prepared :roofing applications. Minimum deck requirements shall. be in compliance with applicable building .code. WeatherWatch Mineral. Surfaced Leak Barrier; StorrnGuard' Film: Surfaced .Leak Barrier;. Liberty.TM SBS Self Adhering. Base/Ply Sheet, LibertyTM SA Glass Cap Sheet,. Shingle -Mate' Roof Deck Protection, Deck-Armorrl Premium Breathable Roof Deck Protection, Felt8uster* High -Traction Synthetic Roofing Felt, and Tiger Pawl"'' Roof Deck Protection shall be installed in .strict compliance with applicable Building Code. 4. WeatherWatch Mineral Surfaced Leak Barrier,. StormGuare Film Surfaced Leak -Barrier, LibertyTM SBS Self - Adhering Base/Ply Sheet, Liberty? SA Glass Cap Sheet, Shingle -Nate' Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, .FeltSustef* High_Traction Synthetic Roofing. Felt, and Tiger. Paw"M Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free .of irregularities_ 5. WeatherWatch* Mineral. Surfaced Leak Barrier., StormGuard®.Film Surfaced Leak. Barrier, LibertyT'" SBS: Self - Adhering .BaselPly. Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate Roof: Deck Protection, Deck-Armoirm Prentiurn Breathable Roof -Deck Protection, FeltBuster'o High -Traction Synthetic Rooting Felt, and Tiger PawtM Roof Deck Protection membranes shall not.be applied. over an existing. roof membrane. G. WeatherWatch* Mineral Surfaced Leak Barrier, StormGuard' .Film Surfaced Leak Barrier; LibertyTM .SBS. Self - Adhering Base/Ply .Sheet, LibertyTM SA Glass Cap. Sheet, Shingle -Mated Roof Deck. Protection, Deck -Armor '4 Premium Breathable Roof Deck .Protection, FeltBuster"' High -Traction Synthetic Roofing Felt, and Tiger Paw'" Roof Deck.Protection shall .not lie .left exposed. as a.temporary.roof for longer .than.30 days of application. 7. WeatherWataho Mineral Surfaced .Leak Barrier, Storn!Guard"' Filth Surfaced Leak Barrier, LibertyTM SBS. Self - Adhering. Base/Ply Sheet, LibertyT� SA Glass Cap Sheet,Shingle-Mateo Roof Deck Protection, Deck-ArnrorT"' Premium Breathable Roof Deck Protection, FeltBuster' Hi gh-Tractipn Synthetic Roofing Felt, and Tiger Pawl i1 Roof Deck Protection may beused with any approved roofcovering Notice of Acceptance.listing WeatherWatch' Mineral Surfaced Leak Barrier; StormGuardo Film Surfaced Leak .Barrier, Liberty'rm SBS Self -Adhering. Base/Ply Sheet, Lib&rtyTM SA Glass Cap Sheet, Shingle-MaO Roof Deck Protection; Deck -Armor"" Premium Breathable Roof .Deck. Protection, FeltBustee High -Traction :Synthetic Roofing Felt, and Tiger .Pawl`'' .Roof Deck Protection as: a component part. of an assembly :in the .Notice. of Acceptance. If WeatherWatcht Mineral Surfaced Leak Barrier, StormGuard O Film Surfaced Leak .Barrier, Liberty7C.M SBS Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet,. Shingle -Mate' Roof Deck. Protection,..Deck-Armor rm Premium 1reathable .Roof deck Protection, l;eltBusterA High -Traction Synthetic .Rootng.Feit and Tiger .PawTh" Roof Deck Protection are. not listed; a.request may be made to the Authority:. Having Jurisdiction(AH3) or the Miami -Dade County Product Control Department for approval provided that .appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 8. All. nails: in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the .deck thoroughiy .to. remove any: dust and debris prior to application. Install when temperatures are 45' .F and rising. 9. When. applying the membrane.in the valley.,..startat the low point and work to the high point,. rolling the membrane from .the: center outward: in both directions. NoA N0.: 18-0.119:15 Expiration Date: 01/22/23 Approval Date: 02122/18 Page 9 of 10 LImrrATIONS: 10. Roll :ox broom the ent.'ire: membrane surface. so as to have I OWA contact with the surface, giving:special attention. to overlap areas. 11. Flash vent pipes., stacks; chimneys and penetrations in compliance: with Roof Assembly current.Product Control Notice of Acceptance and applii;able.BuiWing Code. 12. Allproducts listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 6.1 G20-3 of the Florida Administrative Code. 13. All membranes or packaging shall hear the. imprint or identifiable. marking of the manufacturer's name or logo, city and state of .manufacturing facility, and the, following: statement: "Miami -Dade County. Product Control Approved" .or the Miami -Dade County. Product Control Seal asshown below. END OF THIS ACCEPTANCE NOA No.: .18-6119. 15 MIAMMADE COII[ iiY ... F � Expiration ©ate: 02122123 Approval Date: 02/211.1.8 Page 10 of 10