Con,5tiructaon: AddFOGY1� New Construction--Complete xist nAftert k� t � --E '�After
House Infiltration Vest Results SLC Climate Zone 2 /
CFM (50)=_ 3 8 1 i Test Date: ! 3 ( 2 0
Volume= 6 j 1 o D �—
ACH(50)=CFM (50)ji:Gfl I Volume Mechanical Ventilation required less than 3 ACH
Passing results Music be&ACH (50)or less l'ass ( ) Fall
Enery
the building or dwelling unit shall be tested and verified as having an air leakage rate of not exceedingz air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g. (50 Pascals). T esring shall be conducted by either individuals as defined in
Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or(i)or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F BCC Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3,
Testine Cornpany
Company Name: Pro-Duch Services Address: 1915 Rio Vista Drive, Ft.Plerce, FL 34949
I hereby certify thatthe above House Infiltration results demonstrate compliance%lith FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone?.
Signature:
Printed Name: Marirl Klein
Llcense/Certificirdon#: 5061633 RECEIVED