Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
HEATING & COOLING LOAD SUMMARY SHEET I1 Project Name: O�FI[.E eULLoioq "A„ Project Owner: ,4q-C-6rti—Y-lC. TOSS CoMpfr►JY Project Address: FT, Pta ae-a, F�La21 P A Sizing Method Used: ASHRAE Handbook of Fundamentals, 1997, Chapter26 Compliance Criteria: Florida Building Code, 2001 Edition Section 407.1.ABCD.1 Sizing, Exception #1 Heating/Cooling Zone (PHv tcu) Conditioned Floor Area (sq.ft.) IoSo {13% 1G13 l(S2 Outdoor Dry Bulb ( °FDB) 91,0 91,o 9 (, O q 1,,0 Outdoor Wet Bulb (°FWB) 78,0 78.b 78.0 76.o Indoor Dry Bulb (°FDB) 79 O -7S o ZS,o 7a.0 Indoor Relative Humidity 6O7o 5oc7o GbTb S 6% Difference Water Vapor (Grains/lb.) 5915 59.5 S4,S 34,S Cooling Sensible Load (BTUH) 22,2 -t- 27/43o 2b 38)276 Cooling Latent Load (BTUH) 7121?0 -7 713 ?o It, 9'6o Cooling Total Load (BTUH) with required outdoor air MIS-3o 3S7,230 33,610 481230 Heating Total Load (BTUH) with required outdoor air l31SZo 14) S'70 'I1 26 o L4�32p HVAC systems and equipment sizes thus comply with Florida Building Code, 2001 Edition, Section 407.1.ABCD.1.1: lbw 4, A- M 1 ENERGY EFFICIENCY CODE;TOR_BUILDING CONSTRUCTION " Florida Department,of Community Affairs } _ _ EnergyGauge FlaCom v121 FORM 400A 2001 � �- Whole Building Performance Method; for Commercial Buudings Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Short Desc: ATLTROFC03 Project: MFG PLANT - OFFICE Owner: ATLANTIC TRUSS COMPANY Address: Ft. Pierce x City: Ft. Pierce State: Florida PermitNo: Pending Zip: 34954 Storeys: 1 Type: Office (Business) GrossArea: 4952 Class: New Finished building Net Area: 4952 Compliance Summary Component Design Criteria Result Gross Energy Use 95.49 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 1 'COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications Review of the plans and specifications covered by this covered by this calculation are in compliance calculation indicates compliance with the Florida Energy with the Florida Energy EfBcien Code. Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. PREPARED BY: BUILDING OFFICIAL: DATE: DATE: I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Cod( SYSTEM DESIGNER ARCHITECT: MECHANICAL: ELECTRICAL: LIGHTING: REGISTRATION/STATE 1 4l (") Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevantinformation is contained on signed/sealed plans. 10/7/03 EoergyGauge FlaCom FLCCSB v1.21 Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100) (WEA File: DAYTONABEACH. Total Design Reference 95.49 100.00 IlCredits & Penalties (if any): Modified Points: = 95.49 PASSES' III ion/03 EnergyGauge FlaCom FLCCSB v1.21 3 Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100) (WEA File: DAYTONABEACH. Other Envelope Requirements Item Zone Description Design Limit Meet Req. Zo 1 Zo l Exterior Roof - Max Uo Limit 0.05 0.09 Yes Zo2 Zo2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes Zo3 Zo3 Exterior Roof - Max Uo Limit 0.05 0.09 Yes Zo4 Zo4 Exterior Roof - Max Uo Limit 0.05 0.09 Yes Meets Other Envelooe Reauirements External Lighting Compliance Allowance Area or ELPA CLP Desc Category (W/Unit) a Length (W) (W) 10/7/03 EnergyGauge FlaCom FLCCSB vl.21 Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100) (WEA File: DAYTONABEACIL Lighting Controls Compliance Area No. of Design Min Compli- Acronym ra9ehID Description (sq.ft) Tasks CP CP ance Zolofc 32 Offices (Partitions<3.5 ft below 798 1 4 2 PASSES] ceiling) Open plan offices 900 ft or larger with partitions higher ZOITIt 13 Toilet and Washroom 252 1 2 2 PASSES,] Zo2-Ofc 32 Offices (Partitions<3.5 ft below 871 1 3 3 PASSESJ ceiling) Open plan offices 900 ft or larger with partitions higher Zo2-Sto 44 Storage & Warehouse - Inactive 266 1 2 2 PAS901 Storage Zo3-Ofc 32 Offices (Partitions<3.5 ft below 780 1 3 3 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Zo3-Sto 44 Storage & Warehouse - Inactive 150 1 2 2 fiX StE Storage Zo3-Corr 2 Corridor 683 1 2 2 1?ASSES Zo4-Ofc 32 Offices (Partitions<3.5 ft below 991 1 5 3 ]?A$SES ceiling) Open plan offices 900 ft or larger with partitions higher Zo4-Tlt 13 Toilet and Washroom 161 1 2 2 PASSES? 10/7/03 EnergyGauge FlaCom FLCCSB vl.21 Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100) (WEA File: DAYTONABEACH. System Report Compliance Zol AHU/CU-1 Unitary Systems Caps- Design Eff Design IPLV Comp - Component Category city Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 30200 12.40 10.00 12.40 PASSES Cooling Capacity Heating System Electric Furnace 16380 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 10 0.80 0.80 PASSES System -Supply Constant Volume Zo2 AHU/CU-2 Unitary Systems Capa- Design Eft Design IPLV Comp - Component Category city Eft Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 35600 12.40 10.00 12.40 PASSES Cooling Capacity Heating System Electric Furnace 16380 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 10 0.80 0.80 PASSES System -Supply Constant Volume Zo3 AHU/CU-3 Unitary Systems Caps- Design Eff Design IPLV Comp - Component Category city Elf Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 35600 12.40 10.00 12.40 PASSES Cooling Capacity Heating System Electric Furnace 16380 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 10 0.80 0.80 PASSES System -Supply Constant Volume Zo4 AHU/CU-4 Unitary Systems Capa- Design Eff Design IPLV Comp - Component Category city Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 47000 12.30 10.00 12.30 PASSES Cooling Capacity Heating System Electric Furnace 16380 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 10 0.80 0.80 PASSES System -Supply Constant Volume 10/7/03 EnergyGauge FlaCom FLCCSB vl.21 Plant Compliance Installed Design Min Design Min Comp Description No Size Eff Eff IPLV IPLV Category liance Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100) (WEA File: DAYTONABEACH. Water Heater Compliance Design Min Design Max Comp Desc Type Category Eff Eff Loss Loss liance Water Heater 1 Storage Water Heater - <=120 [gal] & <= 12 1.00 0.88 0.12 PASSES ' Electric [kW] PASSES ' �" Project: ATLTROFC03 Title: MFG PLANT - OFFICE Type: Office (Business) Location: FORT PIERCE, ST L Piping System Compliance Pipe Dia Is Operat Ins Cond Ins Req Ins Comp Category [inches] Runout Temp ]F] Btu-in/h Thick [in] Thick [in] liance r.SF.F Domestic and Service Hot Water Systems 0.75 False 120.00 0.28 1.35 1.33 PASSES 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 :t: ATLTROFC03 MFG PLANT - OFFICE Office (Business) ion: FORT PIERCE, ST L Other Required Compliance 11Category Section Requirement (write N/A in box if not applicable) Check II filtration 406.1 Infiltration Criteria have been met rstem 407.1 HVAC Load sizing has been performed entilation 409.1 Ventilation criteria have been met DS 410.1 Duct sizing and Design have been performed & B 410.1 Testing and Balancing will be performed lectrical 413.1 Metering criteria have been met otors 414.1 Motor efficiency criteria have been met ighting 415.1 Lighting criteria have been met & M 102.1 Operation/maintenance manual will be provided to owner oof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 8 L ENERGY -EFFICIENCY CODE'EOR BUILDING CONSTRUCTION{ f <n; Florida Department Of COu11RUnity Affairs EuergyGaage FlaCom v1.21 Input Data report Proiect Data Proiect Name:' ATLTROFC03 Address: g Ft. Pierce State• Florida Zip: 34954 Owner: ATLANTIC TRUSS COMPANY Building Type: Office (Business) Bmlam Classification: New Finished building No.of Storevs: 1 Azimuth: 0.00 GrossArea: 4952 Zone Report Acronym Description Type Load Profile 1 Zol Zone I CONDITIONED Uses Building Load Profile ❑ 2 Zo2 Zone 2 CONDITIONED Uses Building Load Profile ❑ 3 Zo3 Zone 3 CONDITIONED Uses Building Load Profile ❑ 4 Zo4 Zone 4 CONDITIONED Uses Building Load Profile ❑ 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 I Space Report Description Acronym Depth Width Height Multi Area Volume ft It It plier SF CF aces in Zone: Zol 1 Ofc ZolOfc 57.0 14.0 10.0 1.00 798 7980 Offices (Partitions<3.5 ft below ceiling) Open plan offices 900 ft or larger with partitions higher - 2 Toilets Zo1T1t 10.0 25.2- 10.0 1.00 252 2520 Toilet and Washroom Spaces in Zone: Z02 1 Office Zo2-Ofc 10.0 87.1 10.0 1.00 871 8710 Offices (Partitions<3.5 ft below ceiling) Open plan offices 900 ft or larger with partitions higher 2 Storage Zo2-Sto 10.0 26.6 10.0 1.00 266 2660 Storage & Warehouse - Inactive Storage aces in Zone: Zo3 1 Offices Zo3-Ofc 15.0 52.0 10.0 1.00 780 7800 Offices (Partitions<3.5 ft below ceiling) Open plan offices 900 ft or larger with partitions higher 2 Storage Zo3-Sto 15.0 10.0 10.0 1.00 150 1500 Storage & Warehouse - Inactive Storage 3 Corridors Zo3-Corr 68.3 10.0 10.0 1.00 683 6830 Corridor Spaces in Zone: Zo4 1 Offices Zo4-Ofc 10.0 99.1 10.0 1.00 991 9910 Offices (Partitions<3.5 ft below ceiling) Open plan offices 900 ft or larger with partitions higher 2 Toilets Zo4-Tlt 23.0 7.0 10.0 1.00 161 1610 Toilet and Washroom 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 2 Lighting Report No Type Power Control Type No.of W Ctrl pts Lights in Zone: Zol Lights in Space ZolOfc 1 4 1260 ManualOn/Off 4 Lights in Space ZO1TIt 1 9 140 ManualOn/Off 2 Lights in Zone: Zo2 Lights in Space Zo2-Ofc 1 4 1680 ManualOn/Off 3 Lights in Space Zo2-Sto 1 4 210 ManualOn/Off 2 Lights in Zone: Zo3 Lights in Space Zo3-Ofc 1 4 1560 ManualOn/Off 3 Lights in Space Zo3-Sto 1 4 140 ManualOn/Off 2 Lights in Space Zo3-Corr 1 4 1100 ManualOn/Off 2 Lights in Zone: Zo4 Lights in Space Zoo-Ofe 1 4 1610 ManualOn/Off 5 Lights in Space Zoo-Tlt 1 9 210 ManualOn/Off 2 Wall Report Wall Description Width H (Effec) Multi Area Azimut ft ft plier sf It Walls in Zone: Zol 1 CBS+R3 14.00 11.17 1.00 156.38 0 cont... 2 CBS+R3 75.00 11.17 1.00 837.75 90 cont... Walls in Zone: Zo2 1 CBS+R3 25.00 11.17 1.00 279.25 90 cont.. 2 CBS+R3 50.00 11.17 1.00 558.50 180 cant.. 3 CBS+R3 21.00 11.17 1.00 234.57 270 cant.. Walls in Zone: Zo3 1 CBS+R3 13.00 11.17 1.00 145.21 0 cont.. Walls in Zone: Zo4 1 CBS+R3 87.00 11.17 1.00 971.79 270 cont.. 2 CBS+R3 23.00 11.17 1.00 256.91 0 cont.. 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 Wall Report Cont......... Wall Description Type Cond. Dens. Sp Heat R Btu/lu. Sf. F Ib/cr Btu/Ib. F h.sLFBtu Walls in Zone: I CBS+R3 Zol Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 2 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 ❑ Walls in Zone: Zo2 1 - CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5" 0.20 4.9 ❑ 2 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 3 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 ❑ Walls in. Zone: Zo3 1 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 Walls in Zone: Zo4 1 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 0.20 4.9 ❑ 2 CBS+R3 Stucco/8"CMU/R3insul/GypBd 0.20 60.5 ,, 0.20 4.9 Window Report Zone Wall Window Description Type Men (Btu/hr Sf F) 1 1 1 North -A Window 1.00 cont... 1 2 1 East -A Window2 1.00 coat... 1 2 2 East-B Window 1.00 cant... 1 2 3 East-Al/GI Door Window 2 1.00 cont... 2 1 1 AL/GI Door Window 2 1.00 cant... 2 2 1 South-B Window 2 1.00 cant... 2 3 1 West -A Window 2 1.00 cont... 4 1 1 West -A Window 2 1.00 cont... 4 1 2 West-AI/GI Doors Window 2 1.00 cons... 4 2 1 North -A Window 1.00 cont... 10/7/03 EnergyGauge FlaCom FLCCSB vl.21 Window Report Cont.... Zone Wall Wind Shaded SC Vis.Tr W H (Effec Multi Area Total Area (Y/N) (ftl (ft) plier (Sf) (St) CHI I 1 1 True 1.0 1.0 4.0 6.0 1.00 20.19 20.19 1 2 1 True 1.0 1.0 4.0 6.0 1.00 20.19 20.19 1 2 2 True 1.0 1.0 4.0 2.0 1.00 8.59 8.59 1 2 3 True 1.0 1.0 2.0 6.0 1.00 15.00 15.00 2 1 I True 1.0 1.0 2.0 6.0 1,00 15.00 15.00 2 2 1 True 1.0 1.0 4.0 2.0 6.00 8.59 51.53 2 3 I True 1.0 1.0 4.0 6.0 1.00 20.19 20.19 ❑ 4 1 1 True 1.0 1.0 4.0 6.0 5.00 20.19 100.93 ❑ 4 1 2 True 1.0 1.0 5.0 6.0 1.00 30.00 30.00 ❑ 4 2 1 True 1.0 1.0 4.0 6.0 1.00 20.19 20.19 ❑ Door Report Door Description Shaded Width H (Effec) Multi Area ? it ft plier sf Doors in Zone: Zol Doors in Wall: Zol-Ea 1.00 Al -GI Door False 3.00 2.00 1.00 6.00 Doors in Zone: Zo2 Doors in Wall: Zo2-Ea 1.00 Fast-Al/GI Door False 3.00 2.00 1.00 6.00 Doors in Zone: Zo4 Doors in Wall: Zo4-We 1.00 AUGI Doors False 6.00 2.00 1.00 12.00 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 Door Report Cont.... Wall Type Cond. Dens. Sp Heat R Btu/hr. SE F lb/cf Btu/Ib. F h.sf.F/Btu Doors in Zone: Zol Doors in Wall: Zol-Ea 1.00 Aluminum door, 1.25 in. polystyrene 0.19 43.67 0.11 5.21 [ Doors in Zone: Zo2 Doors in Wall: Zo2-Ea 1.00 Aluminum door, 1.25 in. polystyrene 0.19 43.67 0.11 5.21 [ Doors in Zone: Zo4 Doors in Wall: Zo4-We 1.00 Aluminum door, 1.25 in. polystyrene 0.19 43.67 0.11 5.21 [ Roof Report Roof Description Width H (Effec) Multi Area Tilt ft ft plier sf deg Roofs in Zone: Zol 1 MtVAttic/R19/Acous 14.00 75.00 1.00 1,050.00 0.00 Cont Roofs in Zone: Zo2 1 Mtl/Attic/R19/Acous 50.00 22.74 1.00 1,137.00 0.00 cont Roofs in Zone: Zo3 1 M1VAttic/RI9/Acous 161.30 10.00 1.00 1,613.00 0.00 cont. Roofs in Zone: Zo4 1 Mtl/Attic/R19/Acous 115.20 10.00 1.00 1,152.00 0.00 cont. Roof Report Cont........ Roof Description Type Cond. Dens. Sp Heat R Btu/hr. SE F Ib/cf Btu/1b. F h.sf.FBtu Roofs in Zone: Zol 1.00 Mtl/AUic/RI9/ ShngVI/2"WD Deck/WD Truss/6'Batt/ 0.05 10.89 0.22 21.24 Roofs in Zone: Zo2 1.00 MtVAttic/RI9/ ShngVl/2"WD Deck/WD Truss/6'Batt/ 0.05 10.89 0.22 21.24 Roofs in Zone: Z03 1.00 MtVAttic/RI9/ ShngVl/2"WD Deck/WD Truss/6'Batt/ 0.05 10.89 0.22 21.24 Roofs in Zone: Zo4 1.00 MtVAttic/R19/ Shngl/1/2"WD Deck/WD Truss/6'Batt( 0.05 10.89 0.22 21.24 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 Skylight Report_ Zone Roof Sky Description Type UCen Shading (BhDbr Sf Coeff cont.. Skylight Report Cant..... Zone Roof Skyli Vis.Tra W H (Effec Multiplier Area Total Area CHK ght (ftl (ftl (SO (SO El FloorReport Floor Description Width H (Effec) Multi Area ft ft plier sf Floors in Zone: Zol 1.00 Slab on Grade 14.00 75.00 1.00 1,050.00 Floors in Zone: Zo2 1.00 Slab on Grade 50.00 22.74 1.00 1,137.00 Floors in Zone: Zo3 1.00 Slab on Grade 161.30 10.00 1.00 1,613.00 Floors in Zone: Zo4 1.00 Slab on Grade 115.20 10.00 1.00 1,152.00 Plant Report Equipment Category Incl. Size Inst.N Eft IPLV CHK Water Heater Report W-Heater Description Cap Cap.Uni UP Rt. I/P Rt.Uni' EM EffUni Loss LossUnt CHK 1 Storage WaterHeater- Electric 40.00 1 4.50 1 1.00 1 0.12 1 ❑ 10/7/03 EnergyGauge FlaCom FLCCSB v1.21 Ext-Lighting Report Description Categories. Area Wattag CHK (Si) (kW) 10MO3 EnergyGauge FlaCom FLCCSB v1.21 8