HomeMy WebLinkAboutAtlantic Truss Inspection Reportd4/14/MN 12::iy 1121I Jb1/ Mushy ASSW HAVE e2/ DATE: N: IMOSBY AND ASSOCIATES, L1'C CONSULTING ENGINEERS CA 3728 2435 - I e" AVTNUE VERO BEACH, FLORIDA 32960 PI-IONE (772) 569-0035 FAX (772) 773-3617 Orville wmx INSPECTED: pRRO.IECT NUMBER: 03-37313 COPY ' FAX TO: File ATLANTIC TRUSS IN REPORT WEA' Structural inspection for footings carried out and found them satisfactory according to the construction drawings Following minor corrections were asked to do prior to concreting. • CIean all loose soil on the bottom of reinforcement • Correct chairs to keep the reinforcement in one plane and keeping the 22" clearance as specified in the drawings to A2, A3, A4, A5, A,6 and D1.1, D7 • Add a 4ft #5 bar to the short bar that is not running all rite way till end on footing DI 1 Site foreman engaged workers for the corrections while inspector is on site. s>IjoM aIIGnd WE a a adb INSPECTOR 144w B'u'Le� P cr 412-1