ATLANTIC TRUSS
IN REPORT
WEA'
Structural inspection for footings carried out and found them satisfactory according to the construction drawings
Following minor corrections were asked to do prior to concreting.
• CIean all loose soil on the bottom of reinforcement
• Correct chairs to keep the reinforcement in one plane and keeping the 22" clearance as specified in the
drawings to A2, A3, A4, A5, A,6 and D1.1, D7
• Add a 4ft #5 bar to the short bar that is not running all rite way till end on footing DI 1
Site foreman engaged workers for the corrections while inspector is on site.