HomeMy WebLinkAboutDesign Certification for Wind Load Compliance.•R.n�—an�l.�u.n 561 465 1448 A;e. 9 P.ei2 St. Lucie County Building and Zoning Department 2300 VirginhrAvenue Fort Pierce, FL 34982 561462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring building permit; and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns orother similar component is being effected) and certain other minor building Permits. For further assistance. please contact the Building Inspection Office at 462-1553 or 462-21 T) Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted'on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. v -` Desittn Parameters and Assumptions Used: (p. ease check or complete the appropriate box.) 1. Plorida Building Code 2001 Edition i/ ASCE 7-98 2. Building Design is (check one) Enclosed ✓ Partially Enclosed _ Open Building 3. Building Height: 4, Wind Speed Used in Building Design: -49 3 second gust S. Wind Exposure Classification (refer to exposure tables In Building Code identified in Line #1): /S 6. Average Wind Velocity Pressure on Exterior Faces or Structure ZS. PSF 7. Peak Wind. Velocity Pressure on Exterior Faces of Structure 09,o pup & Importance/Use Factor (obtain from Building Code): 1.O 9. Loads: Floor /Zs� PSF Roof/dead 2 s� PSF Roofflive Z(J PSF 10. Were Shear Walls Considered for Structure (check one): Yes X No ----fif No, attach explanatlow 11. Is a Continuous Load Path Provided (check one): Yes -XL No (if No, attach explanation) IL. Are Component and Cladding Detail Provided (check one): Yes -YC, No _(ff No, attach explangdon) 13. Minimum Soil Bearing Pressure: 2020 PSF As witnessed by my 1,1 ereby certify that the information included with this certification is tStte and correct, to the b o nowt nd'belief. " ` " Name: Certification #:`.Sseal Herat .' Design Firm: Date: (0.4 . SLiCDV Form 9 M QQ