HomeMy WebLinkAboutNuclear Density Test ResultsKSM a KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 MARTIN (772) 337-7755 SEBASTIAN (772) 589-0712 E.B.: 5693 PALM BEACH (561) 845-7445 MELBOURNE (321) 768-8488 FAX (772) 589-6469 ST. LUCIE (772) 229-9093 April 1, 2004 Shelton Construction 2130 N. U.S. 1 Ft. Pierce, Florida 32947 Re: Large Building Column Pads Large Building, & Small Building Atlantic Truss Feeder Road St. Lucie County, Florida Permit #: 24011465 KSM No. 42856-1d Dear Sir: I APR 0 i 2004 No mg -- St. Lucie County Publ— I Wo rk POSTED Enclosed, please find the nuclear density test results performed on the compacted foundation fill at the above referenced project. you have any questions, please feel free to call. 41 e r, P.E. Copy to St. Lucie +Cunty Building DepaJrent KSM KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 MARTIN (772) 337-7755 SEBASTIAN (772) 589-0712 E.B.: 5693 PALM BEACH (561) B45-7445 MELBOURNE (321) 768-8488 FAX (772) 589-6469 ST. LUCIE (772) 229-9093 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED: April 1, 2004 JOB #: 42856-1d/BJ/ley PERMIT #: 24011465 CONTRACTOR: Shelton Construction JOB LOCATION: Atlantic Truss Feeder Road St. Lucie County, Florida ITEM TESTED: Compacted Foundation Fill on the Large Building (250' x 255"), Column Pads of Large Building, and Small Building (50' x 100') MATERIAL: A) Grayish Brown Sand B) Brown Sand TEST LOCATION DEPTH MOIS- PEN DRY MAX. DRY PERCENT OF SAMPLE TURE DENSITY PROCTOR COMPACTION VALUE Column Pads of Large Buildin 1. Pad F10 48" — 60" 13.8 51 108.2 A) 110.4 98.0 2. Pad F7 53 108.6 98.4 3. Pad F4 55 109.4 99.1 4. Pad D2 51 108.8 98.6 5. Pad D5 55 109.4 99.1 6. Pad D8 52 108.4 98.2 KSM KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 MARTIN (772) 337-7755 SEBASTIAN (772) 589-0712 E.B.: 5693 PALM BEACH (561) 845-7445 MELBOURNE (321) 768-8488 FAX (772) 589-6469 ST. LUCIE (772) 229-9093 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED: April 1, 2004 JOB #: 42856-1d/BJ/ley PERMIT #: 24011465 CONTRACTOR: Shelton Construction JOB LOCATION: Atlantic Truss Feeder Road St. Lucie County, Florida ITEM TESTED: Compacted Foundation Fill on the Large Building (250' x 255"), Column Pads of Large Building, and Small Building (50' x 100') MATERIAL: A) Grayish Brown Sand B) Brown Sand TEST LOCATION DEPTH MOIS- PEN DRY MAX. DRY PERCENT OF SAMPLE TURE DENSITY PROCTOR COMPACTION VALUE Large Buildinq 7. N.E. 0" — 12" 9.8 62 115.4 B) 117.0 98.6 8. N.W. 66 116.8 99.8 9. S.W. 63 115.9 99.1 10. S.E. 65 116.5 99.6 Small Buildinq 11. North 0" — 12" 9.6 61 115.2 B) 117.0 98.5 12. South 11 11 63 115.8 " 99.0 KSM KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 MARTIN (772) 337-7755 SEBASTIAN (772) 589-0712 E.B.: 5693 PALM BEACH (561) 845-7445 MELBOURNE (321) 768-8488 FAX (772) 589-6469 ST. LUCIE.(772) 229-9093 MOISTURE -DENSITY RELATIONSHIP MODIFIED PROCTOR (ASTM D 1557) DATE TESTED: April 1, 2004 JOB #: 42856-1p PERMIT M 24011465 CONTRACTOR: Shelton Construction JOB LOCATION: Atlantic Truss Feeder Road St. Lucie County, Florida 112 T---1---T---17—1---T---r ---I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 110 r--y---t---I— — 1------r--� LC I I I I I I I U I I I I I I I I a 109t---I---t---F--1---t——t----1 H I I I I I I I = I I I• I I I I C7 108-- +---F----I---i---- --A w I I I I I I I 1074------+---E -- I---+---1­----4 I I I I I I I I I I I I I I I I 1064----4---4----1­---a----I----1­----4 i I I I I I I I 1 I 1 I I I I I 1054----4---+------I----i----�--� 8 9 10 11 12 13 14 15 Moisture - Percent of Dry Weight Soil Description: Grayish Brown Sand Max. Dry Density: 110.4 P.C.F. Optimum Moisture: 12.0 Percent Ronald G. Keller, P.E. President KSM KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 MARTIN (772) 337-7755 SEBAS11AN (772) 589-0712 E.B.: 5693 PALM BEACH (561) 845-7445 MELBOURNE (321) 768-8488 FAX (772) 589-6469 ST. LUCIE (772) 229-9093 MOISTURE -DENSITY RELATIONSHIP MODIFIED PROCTOR (ASTM D 1557) DATE TESTED: April 1, 2004 JOB #: 42856-2p PERMIT M 24011465 CONTRACTOR: Shelton Construction JOB LOCATION: Atlantic Truss Feeder Road St. Lucie County, Florida 1187-- 1---7---r--7---7---r--, I I I I I I I I I I I I I I I I 1171 — — — —— L---L--J-- --L--J I I I I I I I I I I I I I I I ❑ I I I I I I I I 116 1----1---t---r--1---t--- -- 1 U I I I I I I I a I I I I I I I I H I I--- --� ----- ---I--- = 115 w I I I I I I I I Lu I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1124----I---4—-4----E---I----I 6 7 8 9 10 11 12 13 Moisture - Percent of Dry Weight Soil Description: Brown Sand Max. Dry Density: 117.0 P.C.F. Optimum Moisture: 10.8 Percent Ronald G. Keller, P.E. President