TILLIT-TESTING'&-'ENGINEERING COMPANY
WALUR A.TILLIT:,1R.,'P E. IilteciDC00l.com
FL PG License-No.441G7
FL C.A.License Ntl.'OQ067.19
September 1:8, 2019
:1 9-070
Mr.Tim Robinson' .
Managing.Partner
Global Protection Products,:LLC..
4800 SW 51-Street
Davie,:Florida 33314
Re.: State-of Florida Approval Drawing #17-142. Additional limitations for-use of
Component "9A" (sleeve=spacer)for 24 gage Galvanized Steel Storm panel
installation into wood frame structures.
Dear Mr. Robinson.
As per your.request, following are additional limitations for the.use of spacer component
#"W'for panel installation at existing wood frame structures.
These limitations are an addendum'to limitations already indicated in approved Drawing
# 17-142 and-shall be strictly enforced.
Spacer"9N' may be 1 '/a" Long if the following additional limitations are complied•with:
(1)-Installation:is limited to a one story-Buildings with 16-0 Max mean roof height (this is
a.resttiction from any building height currently indicated.on.sheet 11 of approved Drawing
#17-142)
(2)Anchors going thru.component"W.(panel mate female ID or panel mate plus) shall
be spaced maximum at 6 '/4" O..C. (this is-a restriction from 12 '/".O.C. Spacing allowed
on shee 6 of,approved Drawing# 17-142)
(3) Max 24 gage panel leg is limited to 66" at any:opening (this is a restriction from
larger panel lengths allowed on schedule, sheet 11 of approved Drawing # 17-142)
(a).1.?I" Long Spacer component # 79A" shall be as indicated on sheet 2 of approved
Drawing:#17-142. Installation of 1 %long spacer``shall be siMilar to detaij 2W', sheat
6355 N.W.36th Street,Suite 305, Miami,Florida 33166-Phone: (305)871-1530-Fax: (305) 871-1531
ram'
approved Drawing#17-142, and its-valid only to mWhd-zones 1,2 and 3 as deferred
by.ASTM E 1996 standard and the 2017:(64'Editiart)of the Florida Building Code.
Sincerely,
Walter:A.Tillit
President
Tilteco,.Inc.