Loading...
HomeMy WebLinkAboutHealth Department Septic Approval . APPLICATION # AP14Q4753 $TATE OF FLQRID PERMIT # 56-SF 1034801. yr . , DEPARTMENT OF HEALTH. DOCUMENT # :F113.93822 ONSITE' .SEWAGE TREATMENT AND 'DISPOSAL SYSTEM' CONSTRUCTION INSPECTION AND _FINAL 'APPROVAL _DATE PAID: 03/221201:' j�/j FEE PAID:J.1,5.O,O v 1 RECEIPT # 58`PID 3888743 APPLICANT:; Wade,lur`ney'ftmes,LLC AGENT=:, `Wade Jutney K, rues, LLC , PROPERTY ADDRESS': 7105"Brookline Ave Fort::Pierce, FL 34951 LOT:: 26 BLOCK` 106 SUBDIVISION: Lakewood Park ID#: 1301-61141'31-600-0 CHECKED [X} I.TEMS ARE NOT IN COMPLIANCE WITE .'STATUTE OR RULE AM MUST BE. CORRECTED ,TANK INSTALLATION SETBACKS ] [Oil TANK SIZE [1=j 1.080:00 [2-] 300'00 [ 1 [27] SURFACE :WATER FT [ ]_ [021 TANK MATERIAL ConOete [ 1 [281 DITCHES. `FT [ 1 [611 OUTLET DEVICE [' ]. '[291 PRIVATE' WELLS 98 FT } [941 'MULTI;_-CHAMBERE]j [ Y N• j, [ �] [:36} PUBLIC<WELLS FT , [ ] [05] OUTLET'FILTER Polylok PL-68 [ ] '[31] IRRIGATION WELLS FT [ 1 tbel LEGEND- 1 28-015-080C3 2:,7,0-156:-03SC3 [ ] [32.1 POTABLE WATER 00 FT [ ], [071 WATERTIGHT r[ 1, [33,1 BUILDING FOUNDATIONS 5 FT [ j [08], LEVEL '[ 1 [341 PROPERTY LINES 5, FT [ 1 109] DEPTH 'TQ LID [ ]' 1,351 OTHER FT DRAINFIELD INSTALLATION FILLED ^/ MOUND SYSTEM `[ l' 110] AREA [11 525 [2".1' SOFT: [ j j3�6] DRAINFIELD .COVER. ] [11] DISTRIBUTION BOX HEADER [37] SHOULDERS 1 T [12 j NUMBER,OF DRAINLINEB 1,. S.dE1 2. [ l G3t37 SLOPES' 1` '1131 DRAINLZNE SEPARATION L l; [$9] STABILIZATION Oa/,31/2020v [ 1 CIA]. .DRAFNIINE: SLOPE [ ]. [1$]- DAP T4,OF COVER ADDI.TIONAL INFORMATION ] [16] ELEVATION, [ ABOVE / BELOW 7Brt 3.00 [ 7 [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION` [ ' ,1 [:41j STORNWATER RUNOFF [ ] [181 AT DOSING"PUMPS. 1;00 [ ] [42:] bRMC, [ ] [19]r AGGREGATE SIZE [ 1 L431 MAINTENANCE AGREEMENT l [2,01 AGGREGATE EXCESSIVE FINES [ ] [4'41 .BUILDING AREA ] [21] AGGREGATE DEPTH [ ] [45]. -LOCATTON CONFORMS. WITH SITE PLANT FILL. ./ EXCAVATION'MATERIAL., L a [4 61. FINAL SITE; GRADING I [ 1 [22} FILL AMOUNT [ 1 [4.7]: CONTRACTOR Bruce T MC CUllers:.(Refiable T [ 1 [231 FILL TEXTURE [ ] [;4.8]; OTHER ADS MPS-9(9 pipes=2 tier) I l [247 EXCAVATION DEPTH ABANDONMENT 1 ['25']: AREA REPLACED [ ] [49]. TANK PUMPED 1 [261. .REPLACEMENT MATERIAL [ l [•5D] TANK CRUSHED & FILLED Comments: Comments dre on page 2_ CONSTRUCTION [ APPROVED' / St.,Lucie; CHD DATE- 01/29/2020 DISAPPROVED ]' Envtron ntaLSpeci' s.tll ri ` Jingr-airi(ENVIRONMENTALHEALTH) FINAI� SYSTEM [ APPROVED'; / DISAPPROVED ]': ._ St. Lucie CHD; DATE: 03/31/2020 Env onmental Speciallst 11:8 n•J,Ingram(ENVIRONMENTAL HEALTH) "(Explanation of Violations on Following page) DH 4016, 08/09 (Obs.oletes all .previous- editions. which may not- be used): Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database. V'110A AP1464753 EID19348D1',: ' PIYCATION #�Af�14(}4T�3 ! 'STATE} bW IIL?- �,� DLPART Ni OF HE23LTHk P»� # 56 S ' 348U1= , F gNSITF .'SM TRE14TMEhiT �ni�►�sAz ttg Documm # : 1 39 CoNSTRUCTI©I!t INSPECTION, AND FNA� APPRbVAL n�ms` PAxrs 43I2Z1231 r- :, 5 -0 FEE PAID V1_o[ationtumber ll E tQD�eAte- The$ysfem3is sized for,4 bedtd©,ms with.a maximum oncupancy of 8 ersons-(Z per bedroom);for°a total:estfmated>flow of 4OuO' E gPd New ST,,fitter,D7 Barnes l/S,Ct pump,and.5 35'long TRENeEi DF installed °Novrofation%systelxi oK 0,cover Cantractor E hq ified'by.phone. Nee is finaliiispeation for--filled system,-gutters,alarm chesk,.and:friat s►te gMCIiin' W (F,iiispe it d;at tonsfructlgrr inspection. F nal,system_apgcayed Contractor buildirfg_department 0000it final ppotovaf, r r < " i n : f , _ . . r o " , „ , :y - , „ z " , - c ' , , IIEi- 40 6, 08/09 .(Obso].eteis al on wh0.c}i':=ai3y?not+be ;usedk i EH Qatabase'v. 01 _,- . AP140475 ' •EM93480t