Loading...
HomeMy WebLinkAboutHealth Department Septic Approval • �ICATION #:AP1402748 a _ STATE OF FLORIDA PERMIT #:56-SF-1931716 b DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:FI 1391188 •boon aret�'" . CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:03/12/2019 f� / FEE PAID:515.00 V� p� RECEIPT #:56-PID-3883033 APPLICANT: Michael Doyle AGENT: Richard Laventure(Laventure&Associates Inc) PROPERTY ADDRESS: 1703 Paseo Ave Fort Pierce, FL 34982 LOT: 12.13&14 BLOCK: 14 SUBDIVISION: Maravilla Plaza ID#: 2421-802-0185-000-1 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [28] DITCHES 40 FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI—CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS 100 FT [ ] [061 LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 25 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 19 FT [ ] [091 DEPTH TO LID [ 1 [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509.4 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X I ] 1371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [381 SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 03/24/2020 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 11.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 ALARMS [ ] (19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT I ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL I ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE I ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED / St. Lucie CHD DATE: 12/19/2019 DISAPPROVED Enviro ental Specialist II n J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED I. St. Lucie CHIDDATE: 03/24/2020 E vironmental Specialist II rian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1402748 EID1931716 J ®LICATION #:AP1402748 } ( STATE OF FLORIDA PERMIT #:56-SF-1931716 N DEPARTMENT OF HEALTH DOCUMENT #.F11391188 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:03/12/2019 W"s FEE PAID:51 5.00 RECEIPT #:56-PID-3883033 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300 gpd• New ST,filter,and 5x9 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for filled system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP140274B EID1931716