Loading...
HomeMy WebLinkAboutCURRIER-MANUAL JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1 ...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information CURRIER ADDITIONFor:1827 NW BUTTONBUSH CIRCLE, PALM CITY, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh14000 Structure Btuh12385 Ducts Btuh0 Ducts Btuh0Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh14000 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11766 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2802 Ducts Btuh0Central vent (0 cfm) Btuh0 CoolingHeating (none)899899Area (ft²) Equipment latent load Btuh2802 89858985Volume (ft³)Air changes/hour 0.320.61 Equipment Total Load (Sen+Lat)Btuh14568 Equiv. AVF (cfm) 4891 Req. total capacity at 0.70 SHR ton1.4 Heating Equipment Summary Cooling Equipment Summary Make Make RheemTrade Trade RHEEM Model Cond RA1618AJ1NAAHRI ref Coil RBHP-17J06SH1 AHRI ref 7940293Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW4.1 Sensible cooling Btuh12600Heating output Btuh14000 Latent cooling Btuh5400 Temperature rise °F50 Total cooling Btuh18000Actual air flow cfm255 Actual air flow cfm600 Air flow factor cfm/Btuh0.018 Air flow factor cfm/Btuh0.048Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 111.8 ft 37.8 ft 3 Room height 10.0 ft 10.0 heat/coolft 4 Room dimensions ft319.0x1.0 5 Room area 898.5 ft²319.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 530 505 2021 1104 170 145 580 317 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 25 0 395 407 25 0 395 407 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 130 92 369 202 130 92 369 202 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 42.3742.37 38 2 593 1601 38 2 593 1601 11 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 28 28 113 62 28 28 113 62 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 180 146 584 319 50 31 123 67 GG 10B-v10B-v 0.6000.600 ss 16.8016.80 12.0212.02 19 19 324 232 19 19 324 232 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 15 15 533 522 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 250 196 786 429 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 37 3 1304 3192 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 17 1 268 717 0 0 0 0 CC 16D-30td16D-30td 0.0320.032 --0.900.90 0.960.96 899 899 805 863 319 319 286 306 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 899 112 3095 0 319 38 1045 0 6 c) AED excursion 1026 -277 Envelope loss/gain 11189 10675 3828 2917 12 a) Infiltration 2811 790 951 267 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)14000 12385 4779 3645 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 14000 12385 4779 3645 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 14000 12385 4779 3645 Air required (cfm)Air required (cfm)255 600 87 177 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name CLOSET 2 POWDER 2 Exposed wall 7.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft7.0x6.0 ft6.0x6.0 5 Room area 42.0 ft²36.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 70 70 280 153 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 42.3742.37 0 0 0 0 0 0 0 0 11 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10B-v10B-v 0.6000.600 ss 16.8016.80 12.0212.02 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 CC 16D-30td16D-30td 0.0320.032 --0.900.90 0.960.96 42 42 38 40 36 36 32 35 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 42 7 194 0 36 0 0 0 6 c) AED excursion -17 -2 Envelope loss/gain 512 176 32 32 12 a) Infiltration 176 49 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)688 226 32 32 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 688 226 32 32 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 688 226 32 32 Air required (cfm)Air required (cfm)13 11 1 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58Right-Suite® Universal 2019 19.0.07 RSU08101 Page 3...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name TOILET DEN 2 Exposed wall 0 ft 4.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x3.0 ft130.5x1.0 5 Room area 18.0 ft²130.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 42.3742.37 0 0 0 0 0 0 0 0 11 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 40 40 160 88 GG 10B-v10B-v 0.6000.600 ss 16.8016.80 12.0212.02 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 CC 16D-30td16D-30td 0.0320.032 --0.900.90 0.960.96 18 18 16 17 131 131 117 125 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 18 0 0 0 131 4 111 0 6 c) AED excursion -1 -49 Envelope loss/gain 16 16 388 163 12 a) Infiltration 0 0 101 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)16 16 488 652 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 16 16 488 652 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 16 16 488 652 Air required (cfm)Air required (cfm)0 1 9 32 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58Right-Suite® Universal 2019 19.0.07 RSU08101 Page 4...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name M BATH CLOSET 2 Exposed wall 31.0 ft 7.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft212.0x1.0 ft7.0x6.0 5 Room area 212.0 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 170 170 681 372 70 70 280 153 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 42.3742.37 0 0 0 0 0 0 0 0 11 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 10B-v10B-v 0.6000.600 ss 16.8016.80 12.0212.02 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 140 103 414 226 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 37 3 1304 3192 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 CC 16D-30td16D-30td 0.0320.032 --0.900.90 0.960.96 212 212 190 204 42 42 38 40 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 212 31 858 0 42 7 194 0 6 c) AED excursion 1261 -17 Envelope loss/gain 3447 5255 512 176 12 a) Infiltration 779 219 176 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4226 5474 688 226 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4226 5474 688 226 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4226 5474 688 226 Air required (cfm)Air required (cfm)77 265 13 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-28 08:11:58Right-Suite® Universal 2019 19.0.07 RSU08101 Page 5...\Documents\Wrightsoft HVAC\CURRIER ADDITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name NEW BATH 2 Exposed wall 25.0 ft 3 Room height 10.0 heat/coolft 4 Room dimensions ft9.0x11.0 5 Room area 99.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.19 50 50 200 109 .G 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 .W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 .G 4A5-2ob 0.560 e 15.68 42.37 0 0 0 0 11 W 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.19 90 75 300 164 G 10B-v 0.600 s 16.80 12.02 0 0 0 0 G 1A-c1om 1.270 s 35.56 34.77 15 15 533 522 W 13A-4ocs 0.143 w 4.00 2.19 110 93 372 203 G 1A-c1om 1.270 w 35.56 87.06 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.95 17 1 268 717 C 16D-30td 0.032 -0.90 0.96 99 99 89 95 F 22A-tpl 0.989 -27.69 0.00 99 25 692 0 6 c) AED excursion 128 Envelope loss/gain 2455 1939 12 a) Infiltration 628 177 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)3083 2115 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 3083 2115 15 Duct loads -0%0%0 0 Total room load 3083 2115 Air required (cfm)56 102