Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HAAG ADDITION Street: 6789 S. INDIAN RIVER DRIVE City, State, Zip: FT. PIERCE, FL, Owner: --Design Location: FL, Fort Pierce 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(112.6 sqft.) Description a. U-Factor:. Sgl, U=1.05 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=1.05 SHGC: SHGC=0.35 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (1089.0 sqft.) a. Slab -On -Grade Edge Insulation b. N/A c. N/A Glass/Floor Area: 0.103 Builder Name: Permit Office: Permit Number: Jurisdiction: County: St. Lucie (Florida Climate Zone 2 ) New (From Plans) 9. Wall Types(1876.0 sqft.) Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1456.00 ft2 b. Frame - Wood, Adjacent R=11.0 420.00 ft2 1 c. N/A R= ft2 0 d. N/A R= ft2 No 10. Ceiling Types (1089.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1089.00 ft2 1089 b. N/A R= ft2 0 c. N/A R= ft2 11. Ducts R ft2 Area a. Sup: Attic, Ret: Attic, AH: STORAGE 6 125 64.58 ft2 48.00 ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 24.0 SEER:16.00 ft2 13. Heating systems kBtu/hr Efficiency ft2 a. Electric Strip Heat 17.0 COP:1.00 2.000 ft. 0.321 14. Hot water systems Insulation Area a. Propane Tankless R=0.0 1089.00 ft2 b. Conservation features R= ft2 None R= ft2 15. Credits Total Proposed Modified Loads: 42.09 Total Baseline Loads: 44.75 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPA D BY: DATE: - I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 1 gallons EF: 0.600 PASS Pstat - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. = Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/23/2019 11:41 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HAAG ADDITION Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 1089 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6789 S. INDIAN RIVER Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1089 15246 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GAME ROOM/WET 540 7560 No 0 1 Yes Yes Yes 2 BATH 60 840 No 0 1 Yes Yes Yes 3 STORAGE 240 3360 No 0 1 Yes Yes Yes 4 EXERCISE ROOM 249 3486 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GAME ROOM/W 64 ft 0 540 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio BATH 6 ft 0 60 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio STORAGE 16 ft 0 240 ft2 ---- 0 1 0 4SIab-On-Grade Edge Insulatio EXERCISE ROO 18 ft 0 249 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1180 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1089 ft2 N N 9/23/2019 11:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) GAME ROOM/W 30 Blown 540 ft2 0.1 Wood 2 Under Attic (Vented) BATH 30 Blown 60 ft2 0.1 Wood 3 Under Attic (Vented) STORAGE 30 Blown 240 ft2 0.1 Wood 4 Under Attic (Vented) EXERCISE ROO 30 Blown 249 ft2 0.1 Wood WALLS Adjacent Space Cavity Width P Height Sheathing Framing _Ahqoro Solar Below 1 N Exterior Concrete Block - Ext Ins(AAME ROO 4.1 14 0 14 0 196.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext Ins(RAME ROO 4.1 20 0 14 0 280.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext InsGAME ROO 4.1 30 0 14 0 420.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul BATH 4.1 6 0 14 0 84.0 ft2 0 0 0.6 0 _ 5 S Exterior Concrete Block - Ext InstSTORAGE 4.1 16 0 14 0 224.0 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Ext InEXERCISE R 4.1 16 0 14 0 224.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext InfiXERCISE R 4.1 1 0 14 0 14.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Ext In!UXERCISE R 4.1 1 0 14 0 14.0 ft2 0 0 0.6 0 9 N Garage Frame - Wood GAME ROO 11 30 14 420.0 ft2 0 0.23 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 3 Metal Low-E Single Yes 1.05 0.35 N 48.0 ft2 2 ft 0 in 2 ft 0 in None None 2 W 3 Metal Low-E Single Yes 1.05 0.3 N 14.6 ft2 2 ft 0 in 2 ft 0 in None None 3 W 3 Metal Low-E Single Yes 1.05 0.3 N 15.0 ft2 2 ft 0 in 2 ft 0 in None None 4 N 4 Metal Low-E Single Yes 1.05 0.3 N 8.0 ft2 2 ft 0 in 2 ft 0 in None None 5 S 5 Metal Low-E Single Yes 1.05 0.3 N 12.0 ft2 2 ft 0 in 2 ft 0 in None None 6 N 6 Metal Low-E Single Yes 1.05 0.3 N 15.0 ft2 2 ft 0 in 2 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1140 ft2 1140 ft2 30 ft 14 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 1270.5 69.75 131.17 .1928 5 9/23/2019 11:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — -- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 65 ft2 Default Leakage STORAGE (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Venting Jan Feb Mar Apr Jun Jul May Nov Dec LXJ Jun LXJ Jul LXJ Aug LXJ Sep Oct L�l Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 GAME ROOM/WET Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/s .ft. ft2 ft 0.3 EXERCISE ROOM 9/23/2019 11:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HAAG ADDITION Builder Name: Street: 6789 S. INDIAN RIVER DRIVE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: x Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind p s 12ing and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a In adds lnn i— eriinn nF Inn ...w lln ,.1...11 L...:� ____-�____ ._ �.� .�_ • • .. _ .__ —• •••---..._.., .....1............ — .vy r. v...� a„o„ UG 111 O\.\.VIUGIIt:C Mill 111C FJIUVIblUF15 Of Ilil.-41JU. 9/23/2019 11:41 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 • The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location STORAGE 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1089 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.050 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.321 14. Heating system: Capacity 17.0 c) Area 7c. 112.6 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1 la. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatu Date: Address of New Home: 6789 S. INDIAN RIVER DRIVE City/FL Zip: FT. PIERCE. FL 9/23/2019 11:41:05 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1