HomeMy WebLinkAbout204143-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net August 28, 2020 KSM JOB # :204143-1d/CH/ct CONTRACTOR:Ando Building Corporation 389 Sebastian Blvd. Sebastian, FL 32958 JOB LOCATION:5242 Slash Pine Trail Ft. Pierce, Florida PERMIT #: To Whom it may concern, Should you have any question, please feel free to contact our office. Respectfully, Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 08/28/20 Email to: andooffice2015@gmail.com As requested, we tested the compacted fill for the house pad. To determine if the fill was properly compacted on the pad to a depth of 4 feet,we performed nuclear density tests on the top two feet.To estimate the soil density below a depth of 2 feet we used a Static Cone Penetrometer.During the tests,a shaft with a conical point is pushed through soil and the soil resistance measured on a calibrated gauge.After the soil resistance is measured,the hole is advanced with a hand-auger in 1-foot increments to permit a continuation of measurement of density versus depth. Test Results: Nuclear density tests performed on the top 2 feet indicates the compaction exceeds the project specifications of 95%(ASTM 1557).Static Cone Penetrometer readings indicate the compacted backfill below 2 feet are generally well compacted to a depth of 4 feet. Based on the nuclear density tests and Static Cone Penetrometer readings,it appears the fill on the house pad was properly compacted. Proudly Serving Florida since 1990 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:204143-1d/CH/ct PERMIT #:NUC #417 CONTRACTOR:Ando Building Corporation Nuc Model:3500 JOB LOCATION:5242 Slash Pine Trail Nuc Serial #:3417 Ft. Pierce, Florida ITEM TESTED:Compacted Foundation Fill - Main House TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.E.0" - 12"43 109.0 112.2 97.1% 2. S.E."40 108.8 "97.0% 3. Center "46 110.1 "98.1% 4. N.W.12"-24" 44 109.5 "97.6% 5. S.W."40 108.7 "96.9% 6. Center "44 109.2 "97.3% Soil Description: Brown Sand with Shell In Place Moisture: 14.2% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 112.2 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 8/28/2020 Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 August 27, 2020 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 109.0 110.0 111.0 112.0 113.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight