�Elvlca,uc FIELD DENSITY TEST REPORT
Permitting Departmer
Client: Wastewater Tech Inc. Project: 161 NE Serenata Ct. St. Lucie County
Date: 3/21/2020 Project Address: 161 NE Serenata Ct.Port St.Lucie,FL
Report No.: 610-20334-D1
Technician: Ezzat Perez
Proctor Information
No. ISample Location Sample Description Test Method MDD(pcf) oMC(eA)
334,1 Existing Brown Fine Sand AASHTO T 180 100.2 12.6
0
Pro ect Specification Density Test Method ASTM D 6938
98 %Density Requirement(Modified Proctor) ITest Mode I Direct Transmission(Troxier)
Test Results
General Location: Valve Replacement
Test Proctor Test Wet Density Moisture Meet
Depth LHt No. Density
No. Locatlon No. (Pcf) N Dry Camp.(N.) Spec.?
(in) (pcf)
i 6'W and 20'S of NW comer of Bldg 334-1 12' 1 of 1 103.2 5.0 98.3 98.1
2 4 W and W'S of f3W comer of Bldg 3344 12' 1 of 1 103.5 4.3 99.2 99.0 YES
3 9'W and TN of SW comer of Bldg 334-1 12" 1 of 1 107.3 7.2 100.1 99.9 YES-
4 IT W and 10'N of SW comer of Bldg 334-1 12" 1 of 1 107.9 7.6 100:3 100.1 YES
Comments:
lldV c�n�vins LLG
,p�r�� nag - 312V2020
These test resda apply ordy to the spedric locations end materiels noted and may not reprossM any ofter elevations arlocatiars.This report may notion �IONR ��t`\
reproducad,except in full,What the approval of Pacifica Engine ring Sanflo ,U-C.If a nurmnplia¢e eppeas an this report.to de extent that the
reported nmmnpffaroe impacts the pmisct,the msdudm is outside tat PACIRCA of engagement
Pacifica Engineering Services 11181 S Rogers Circle,-Suite 3 1 Boca Raton,FL 33487 1 561-693-8093
Florida Certification of Authorization License No.32328
�PACIRCA1111
�ENGMTUUGJ t ?--ER,ICES,UC FIELD DENSITY TEST REPORT (J Kq
Client: Wastewater Tech Inc. Project: 161 NE Serenata Ct.
Date: 3/21/2020 Project Address: 161 NE Serenata Ct. Port St. Lucie, FL
Report No.: 610-20334-D1
Technician: Ezzat Perez
Proctor Information
No. Sample Location Sample Description Test Method MDD(pcf) OMC(%)
334-1 Existing Brown Fine Sand AASHTO T 180 100.2 12.6
0
Project Specification IDensity Test Method(ASTM D 6938)
98 % Density Requirement(Modified Proctor), ITest Mode I Direct Transmission (Troxler)
Test Results
General Location: Valve Replacement
Test Proctor Test Wet Density Moisture Dry Meet
Location Depth Lift No. a Density Comp.(%)
(/a)No. No. (in) (pcf) (pcf) Spec.?
1 6'W and 20'S of NW corner of Bldg 334-1 12" 1 of 1 103.2 5.0 98.3 98.1 YES
2 4'W and 17'S of NW comer of Bldg 334-1 12" 1 of 1 103.5 4.3 99.2 99.0 YES
3 9'W and TN of SW comer of Bldg 334-1 12" 1 of'1 107.3 7.2 100.1 99.9 YES,
4 13'W and 10'N of SW corner of Bldg 334-1 12" 1 of 1 107.9 7.6 100.3 100.1 YES
Comments:
NN
6 v', u�Ctiq�e,
LL�F*,IA`a Eng7 e24erv►ces, C
d Au o-a n U.Z Z.32328
F 'tl
ley i✓�f`'ostgr,PR'
refC{!ri 'o�} 3238 3/21/2020
These rNt'r7�; N
produced,except iesults n full.Wthout the specific pprovaall of Pacifica Engineering Services,LLC.If arnon-complesent any iance appears on this,report,o the extent that the rt may not a
reported non-compliance impacts the project,the resolution is outside the PACIFICA scope of engagement.
Pacifica Engineering Services 1 1181 S Rogers Circle-Suite 3 1 Boca Raton,FL 33487 561-693-8093
Florida Certification of Authorization License No.32328
Planning & Development Services
Building &Code regulation Division
2300 Virginia Ave
+ R 1, 0 A Fort Pierce, FL 34982 MAR G 4°'2�2t7
772-462-2172,Fax 772-462-6443 PoM tting D;MM90
CERTIFICATE OF TERMITE TREATMENT
.CONSTRUCTION,SOIL.TREATMENT
-PERMIT #.; CI'l CS JOB ADDRESS: IZ-1
BUILDER/CONTRACTOR 1, r� i;� : r��ur�'kjo A.
J
PEST CONTROL CONTRACTOR:
PEST CONTROL LICENSE #: -
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites.in accordance with the standards of the National Pest Control Association.
Square feet if area treated Chemicals used: t�1 r °r� ��'f- r`''
Percentage of solution: _ ' Total gallons used: ��-
Date of Treatment: L,2,1, { `) .> Time of Treatment:
`_ Footing ' :Slab
,-'1�Treatment s J�YV Treatment
Re-Treat Re-Treat
Driveway Pools
1s Treatment 1St Treatment•
Re-Treat Re-Treat
Other Perimeter for Final Inspection
''1s'Treatment y
Re-Treat -}=�> '> ,/6 - -
Signature of Exterminator Date
Note.- There must be a completed form for each required treatment or..re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re inspection
fee charged. „
FBC105.10 Certificate of Protective Treatment for.prevention of termites. A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment CertiFcates as each required protective treatment is completed,
pro viding a copy for the person the permit is issued to and another copy for the building permit files. The Treatment
Certificate shall provide the product used, identity of the applicator, time.and date of the treatment, site location, area
treated, chemical used, percent concentration and number ofgallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for Co, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments.and dates of applications.
Pre-Co' nstruction
Tennite Treatment /2
f:BI'�•]Y•an111�1"lidl ���{ -�/���//,
7670 Okeechobee Blvd., West Palm Beach, Fl. 33411
Phone: 1-600-2 5-7376 Fax: 561-664-0122
Property Information Builder/Contractor
j Treatment Date i 2 at ? Time _73V
Lot Block
Name of Builder
i
Subdivision Name -
Shell Contractor
5- Sep"A ,
Street Address(If known)
Construction Type
City State Zip 7 �Ionolitluc ®Floating/Stemwall ®Pa-
5�,� do
i DDrvewa
_Owner's Name (If known) OEntry y OOther:
Product/Treatment Information
Treatment Type: nderslab ❑Patio/Driveway/Entry ®Final
®Wood Treatment ®Bait System ®Other
Product: ®Disodium Octaborate Cyperrnethrin
L(Iinidaeloprid ®Bifenthrin
71 Perniethrin ®Other:
Concentration , :_tom Mixed Product Applied
Square Feet Treated Linear Feet Treated
Q If this box is checked, then Final Perimeter treatment has
been completed and the following statement is applicable:
Certificate of Compliance: This building has received a complete treatment for the prevention of
subterranean termites. This treatment is in accordance with the laws and rules established by the
Florida Department of Agriculture and Consumer Services.
Applicator's Name (please print) Applicator.' Signature
Hi S-TE019 04/18 Hulett Environmental ServicesC 2018