HomeMy WebLinkAboutcompaction testmw'wArdaman
Density Report Client:
Project:
& Associates, Inc. Permit # 2007-0465
Report Date: 9/2/2020
Port St. Lucie Branch Test Method: ASTM D6938
Florida CA No.5950
460 NW Concourse
Place, Unit 1
Port St. Lucie, 8- 34986
Phone:772-878-0072
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
Test Results
Test #
Retest
Of
Test -
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
N
Remark
349
8/27/20
20-247
(Modified)
A
--
12.5
110.5
9.8
107.6
118.1
12
97
95
Pass
350
8/27/20
20-247
(Modified)
1 A
--
12.5
110.5
10.6
106.7
118.0
12
97
95
Pass
351
8/27/20
20-247
(Modified)
A
--
12.5
110.5
10.4
107.1
118.2
12
97
95
Pass
355
8/27/20
20-247
(Modified)
A
--
12.5
110.5
10.1
105.6
116.3
12
96
95
Pass
356
8/27/20
20-247
(Modified)
A
--
12.5
110.5
10.8
106.9
118.5
12
97
95
Pass
357
8/27/20
20-247
(Modified)
A
-
12.5
110.5
9.2
106.1
115.9
12
96
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model / SN I Calibrated
Field Technician
349
Footings: Footings for 308 Palm Breezes Drive, Lot 118. SE End of Footings
-1.0
Bottom of footings
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
350
Footings: Footings for 308 Palm Breezes Drive, Lot 118. NE End of Footings
-1.0
Bottom of footings
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
351
Footings: Footings for 308 Palm Breezes Drive, Lot 118. NW End of Footings
-1.0
Bottom of footings
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
355
Building Pad Fill: House Pad for 308 Palm Breezes Drive, Lot 118. SE End of Pad
-1.0
ITop of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
356
Building Pad Fill: House Pad for 308 Palm Breezes Drive, Lot 118. SW End of Pad
-1.0
JTop of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
357 1
Building Pad Fill: House Pad for 308 Palm Breezes Drive, Lot 118. NW End of Pad
-1.0
1 Top of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
MOW Ardaman In -Place Density Report Client: Project:
& Associates, Inc. Permit # 2007-0465 Renar Development Corp. 113-15-66-5434B
Report Date: 9/2/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce
Florida CA No. 5950 Fort Pierce, FL
460 NW Concourse Place, Unit 1 i-
Port St. Lucie, FL 34986 j\ I
�/
Phone:772-878-0072 / e-fml
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Sep 02, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the 'SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.