HomeMy WebLinkAboutcompaction testArdaman in -Place Density Report
& Associates, Inc.
Port St. Lucie Branch -
Florida CA No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone: 772-878-0072
Permit # 2006-0868
Report Date: 9/2/2020
Test Method: ASTM D6938
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
t� 5�6 A,Gv - 60?-
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
N
Remark
346
8/27/20
20-246
(Modified)
A
--
8.5
117.0
9.5
114.8
125.7
12
98
95
Pass
347
8/27/20
20-246
(Modified)
A
--
8.5
117.0
9.5
116.7
127.8
12
100
95
Pass
348
8/27/20
20-246
(Modified)
A
--
8.5
117.0
10.6
115.9
128.2
12
99
95
Pass
352
8/27/20
20-246
(Modified)
A
--
8.5
117.0
10.7
115.2
127.5
12
98
95
Pass
353
8/27/20
20-246
(Modified)
A
-
8.5
117.0
8.6
114,1
123.9
12
98
95
Pass
354
8/27/20
20-246
(Modified)
A
--
8.5
117.0
8.8
114.9
125.0
12
98
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN I Calibrated
Field Technician
346
Footings: Footings for 417 Seafoam Circle, Lot 63. NW End of Footings
-1.0
Bottom of footings
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
347
Footings: Footings for 417 Seafoam Circle, Lot 63. SW End of Footings
-1.0
Bottom of footings
CPN / MC-3,/ M340507396 /
Tech, Port St. Lucie
348
Footings: Footings for 417 Seafoam Circle, Lot 63. SE End of Footings
-1.0
Bottom of footings
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
352
Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. NW End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
353
Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. NE End of Pad
-1.0
1
Top of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
354
Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. SE End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
Ardaman in -Place Density Report Client: Project:
& Associates, Inc. Permit # 2006-0868 Renar Development Corp. 113-15-66-5434B
Report Date: 9/2/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Part St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce
Florida CA No. 5950 ,/ Fort Pierce, FL
Port
Nt. Concourse Place, Unit 1 ler)�71
�mayPort St. Lucie, FL 34986 /o T/J'Phone:772-878-0072
� ` • ,//�� r'
�. No.3991 -
1
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Sep 02, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.