Loading...
HomeMy WebLinkAboutcompaction testArdaman in -Place Density Report & Associates, Inc. Port St. Lucie Branch - Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 Permit # 2006-0868 Report Date: 9/2/2020 Test Method: ASTM D6938 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 t� 5�6 A,Gv - 60?- Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 346 8/27/20 20-246 (Modified) A -- 8.5 117.0 9.5 114.8 125.7 12 98 95 Pass 347 8/27/20 20-246 (Modified) A -- 8.5 117.0 9.5 116.7 127.8 12 100 95 Pass 348 8/27/20 20-246 (Modified) A -- 8.5 117.0 10.6 115.9 128.2 12 99 95 Pass 352 8/27/20 20-246 (Modified) A -- 8.5 117.0 10.7 115.2 127.5 12 98 95 Pass 353 8/27/20 20-246 (Modified) A - 8.5 117.0 8.6 114,1 123.9 12 98 95 Pass 354 8/27/20 20-246 (Modified) A -- 8.5 117.0 8.8 114.9 125.0 12 98 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN I Calibrated Field Technician 346 Footings: Footings for 417 Seafoam Circle, Lot 63. NW End of Footings -1.0 Bottom of footings CPN / MC-3 / M340507396 / Tech, Port St. Lucie 347 Footings: Footings for 417 Seafoam Circle, Lot 63. SW End of Footings -1.0 Bottom of footings CPN / MC-3,/ M340507396 / Tech, Port St. Lucie 348 Footings: Footings for 417 Seafoam Circle, Lot 63. SE End of Footings -1.0 Bottom of footings CPN / MC-3 / M340507396 / Tech, Port St. Lucie 352 Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. NW End of Pad -1.0 Top of pad CPN / MC-3 / M340507396 / Tech, Port St. Lucie 353 Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. NE End of Pad -1.0 1 Top of pad CPN / MC-3 / M340507396 / Tech, Port St. Lucie 354 Building Pad Fill: House Pad for 417 Seafoam Circle, Lot 63. SE End of Pad -1.0 Top of pad CPN / MC-3 / M340507396 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Ardaman in -Place Density Report Client: Project: & Associates, Inc. Permit # 2006-0868 Renar Development Corp. 113-15-66-5434B Report Date: 9/2/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Part St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce Florida CA No. 5950 ,/ Fort Pierce, FL Port Nt. Concourse Place, Unit 1 ler)�71 �mayPort St. Lucie, FL 34986 /o T/J'Phone:772-878-0072 � ` • ,//�� r' �. No.3991 - 1 This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Sep 02, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.